HomeMy WebLinkAboutEL102A - SECOND FLOOR ELECTRICAL PLAN - AREA AM
M
M
M
M
M
M
M
M
EW3EW3EW3EW3EW2bEW3EW3EW3EW3EW3LF3LF3CFB CFBLF1LF1LF1 LF1LF1LF1LF1LF1LF1LF1LF1LF1LF4LF4631154631154631154LF3LF1LF1LF1LF1LF1LF1LF1LF1LF1CFBLF4LF1LF1LF3
LF1
LF1
LF1
LF1
LF1
LF1
LF1
LF1
LF1
CFB
LF4
LF1
LF1
CFB
LF5
LF5
LF1
LF1 LF1 LF1
LF1
LF1
LF1
LF1
LF1
LF1
LF4
LF4
LF4
LF1
LF1
LF1
LF1 LF1
CFB
LF4
CFB
C2
LF5
LF1LF1
LF4LF4
LF5
LF5
LF1
LF1
LF1
LF1
LF1
LF1LF1
LF1
LF1 LF1LF1
LF1LF1
LF1
LF1 LF1LF1LF1LF1 CFB LF1LF1LF3 LF1LF1 LF1LF1LF1LF1LF1LF1LF1 CFB LF4LF1LF1LF3LF1LF1LF1LF1LF1LF1LF1LF1LF1CFBLF4LF1LF1CFBLF4 CFBC1LF5LF1LF1 LF4LF4 LF5LF5LF1 LF1LF1LF1LF1LF1LF1 LF1 LF1 LF1 LF1 LF1LF1 LF1DNUPLF1
LF1
LF1
LF1
LF1LF1
LF1
LF1
LF1
LF3
CFB
LF1
LF1
LF4LF1LF1 LF1LF1LF1LF1LF1LF1 LF1 LF3 CFB LF1LF1 LF4LF1LF1 LF1LF1LF1LF1LF1 LF1 LF1 LF3 CFB LF1LF1 LF4 LF1LF1LF1LF1LF1LF1LF1LF1LF1LF3CFBLF1LF1LF4MMMLF11
LF11 LF11
LF11
LF11
LF11
LF11
LF11
LF11
LF11
LF11
LF11
LF11
LF11
LF11
LF11 LF11
LF11
LF11
LF11
LF11 LF11 LF11 LF11 LF11 LF11 LF11
LF11
LF14
LF14
UNIT B1
22
UNIT A1
23
UNIT B2
36UNIT A1
19
UNIT A1
18
UNIT B1
35
UNIT A1
17
UNIT B1
34
UNIT C1
16
1 / E403
1 / E402
1 / E402
1 / E402
1 / E401
1 / E401
1 / E401
1 / E401
UNIT C2
14
3 / E403
UNIT A1
92
1 / E401
UNIT A1
93
UNIT A1
94
1 / E401
1 / E401
UNIT B3
20
UNIT A1
21
3 / E402
1 / E401
3 / E402
HP2 -2
HP2 ELECTRICAL
203
LF12
LF12
DATA
202
HP2 -22
HP1A - 9 HP1A -9
X1
X1
X1
X1
X1
X1
X1
HP2 -2
LF12
LF12
LF12
LF11
LF12
LF11
LF11
LF11
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM LF17LF17
LF17
LF17
LF17 LF17
EM
LF17
LF17
LF17
LF17
LF17
LF17
LF17
LF17LF17 ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET
APRIL 28TH, 2021
20005THE AVANTPHASE IIEL102ASECOND FLOORELECTRICAL PLAN -AREA ACARMEL,INGENERAL NOTES
A WIRE EVERY THIRD HALLWAY FIXTURE, FIXTURES AT EGRESS DOORS AND
FIXTURES AT HALLWAY INTERSECTIONS TO BE ALWAYS ON (NO OCCUPANCY
SENSOR CONTROL).
B GROUP OCCUPANCY SENSORS TO CONTROL UNBROKEN SECTIONS OF
HALLWAY.
C WALL SCONCES MOUNTED PERPENDICULAR TO FLOOR WITH FIXTURE
CENTER AT 6'-0" AFF.
D EMERGENCY LIGHT FIXTURE LOCATIONS SHOWN ARE NOT EXACT. SPACE
FIXTURES AT APPROXIMATELY 18'-0" ON CENTER OR ACCORDING TO
MANNUFACTURERS RECOMENDATION. MOUNT AT 7'-6" AFF.
E OCCUPANCY SENSOR LOCATIONS SHOWN ARE NOT EXACT. CENTER
SENSORS WITHIN HALLWAY AND SPACE AT APPROXIMATELY 30'-0" ON
CENTER OR ACCORDING TO MANNUFACTURERS RECOMENDATION. MOUNT TO
BOTTOM OF DUCT SUPPORTS. COORDINATE WITH MECHANICAL.
F MOUNT EXIT SIGNS AT 7'6". WALL MOUNT WHERE POSSIBLE. PENDENT MOUNT
ELSEWHERE.
1/8" = 1'-0"
SECOND FLOOR LIGHTING PLAN -AREA A1
# DESCRIPTION DATE
1 ASI-01 12/14/2020
10/11/21