HomeMy WebLinkAboutEL103A - THIRD FLOOR ELECTRICAL PLAN - AREA AM
M
M
M
M
M
M
M MEW3EW3EW3EW3EW2bEW3EW3 EW3EW3EW3CFBLF4 CFBC1LF5LF1LF1 LF4LF4 LF5LF5LF1LF1 LF1LF1LF1LF1LF1LF1LF1 LF1 LF1 LF1LF1 LF1LF3LF3CFB CFBLF1LF1LF1 LF1LF1LF1LF1LF1LF1LF1LF1LF1LF4LF4631154CFB
LF5
LF5
LF1
LF1 LF1 LF1
LF1
LF1
LF1
LF1
LF1
LF1
LF4
LF4
LF4
LF1
LF1
LF1
LF1 LF1
CFB
LF4
CFB
C2
LF5
LF1LF1
LF4LF4
LF5
LF5
LF1
LF1
LF1
LF1
LF1
LF1LF1
LF1
LF1 LF1 LF1
LF1LF1
LF1
LF3LF1LF1LF1LF1LF1LF1LF1LF1LF1CFBLF4LF1LF1LF3
LF1
LF1
LF1
LF1
LF1
LF1
LF1
LF1
LF1
CFB
LF4
LF1
LF1 631154LF3LF1LF1LF1LF1LF1LF1LF1LF1LF1CFBLF4LF1LF1LF3 LF1LF1 LF1LF1LF1LF1LF1LF1LF1 CFB LF4LF1LF1LF1 LF1LF1LF1LF1 CFB LF1LF1631154DNUP LF1
LF1
LF1
LF1
LF1LF1
LF1
LF1
LF1
LF3
CFB
LF1
LF1
LF4LF1LF1 LF1LF1LF1LF1LF1LF1 LF1 LF3 CFB LF1LF1 LF4LF1LF1 LF1LF1LF1LF1LF1 LF1 LF1 LF3 CFB LF1LF1 LF4 LF1LF1LF1LF1LF1LF1LF1LF1LF1LF3CFBLF1LF1LF4M
M
LF14LF14
1 / E403
1 / E401
1 / E401
1 / E401 1 / E402
1 / E402
1 / E401
2 / E402
UNIT C2
99
3 / E403
UNIT A1
100
1 / E401
UNIT B3
118
3 / E402 UNIT A1
119
1 / E401
UNIT A1
120
UNIT A1
121
1 / E401
1 / E401
LF12
LF12
LF12
MECH
309
LF12
HP1A - 9 HP1A - 9
UNIT C1
142 UNIT B1
152
UNIT B1
153
UNIT A1
144
UNIT B2
154
UNIT A1
147
UNIT B1
146
1 / E402
X1X1
X1
X1
X1
X1
X1
LF12
LF12
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EMLF17
LF17
LF17
LF17
LF17
LF17
LF17
LF17
LF17 LF17
LF17
LF17
LF17
LF17
LF17
LF17
LF11 LF11
LF11
LF11 LF11
LF11
LF11
LF11
LF11
LF11
LF11
LF11
LF11
LF11
LF11
LF11
LF11
HP2 -20
LF11 LF11
LF11
LF11
LF11
LF11
LF11 LF11
LF11 LF11
LF11
LF11
LF11 LF11
HP2 -20
HP2 -11 ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET
APRIL 28TH, 2021
20005THE AVANTPHASE IIEL103ATHIRD FLOORELECTRICAL PLAN -AREA ACARMEL,INGENERAL NOTES
A WIRE EVERY THIRD HALLWAY FIXTURE, FIXTURES AT EGRESS DOORS AND
FIXTURES AT HALLWAY INTERSECTIONS TO BE ALWAYS ON (NO OCCUPANCY
SENSOR CONTROL).
B GROUP OCCUPANCY SENSORS TO CONTROL UNBROKEN SECTIONS OF
HALLWAY.
C WALL SCONCES MOUNTED PERPENDICULAR TO FLOOR WITH FIXTURE
CENTER AT 6'-0" AFF.
D EMERGENCY LIGHT FIXTURE LOCATIONS SHOWN ARE NOT EXACT. SPACE
FIXTURES AT APPROXIMATELY 18'-0" ON CENTER OR ACCORDING TO
MANNUFACTURERS RECOMENDATION. MOUNT AT 7'-6" AFF.
E OCCUPANCY SENSOR LOCATIONS SHOWN ARE NOT EXACT. CENTER
SENSORS WITHIN HALLWAY AND SPACE AT APPROXIMATELY 30'-0" ON
CENTER OR ACCORDING TO MANNUFACTURERS RECOMENDATION. MOUNT TO
BOTTOM OF DUCT SUPPORTS. COORDINATE WITH MECHANICAL.
F MOUNT EXIT SIGNS AT 7'6". WALL MOUNT WHERE POSSIBLE. PENDENT MOUNT
ELSEWHERE.
1/8" = 1'-0"
THRID FLOOR LIGHTING PLAN -AREA A 1
# DESCRIPTION DATE
1 ASI-01 12/14/2020
10/11/21