Loading...
HomeMy WebLinkAboutEP102A - SECOND FLOOR ELECTRICAL PLAN - AREA AT T F F SFFSS S FSS S S S S S JJEW3EW3EW3EW3EW2bEW3EW3EW3EW3EW3LF3LF3CFB CFBLF1LF1LF1 LF1LF1LF1LF1LF1LF1LF1LF1LF1LF4LF4631154631154631154LF3LF1LF1LF1LF1LF1LF1LF1LF1LF1CFBLF4LF1LF1LF3 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 CFB LF4 LF1 LF1 CFB LF5 LF5 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF4 LF4 LF4 LF1 LF1 LF1 LF1 LF1 CFB LF4 CFB C2 LF5 LF1LF1 LF4LF4 LF5 LF5 LF1 LF1 LF1 LF1 LF1 LF1LF1 LF1 LF1 LF1 LF1 LF1LF1 LF1 LF1 LF1LF1LF1LF1 CFB LF1LF1LF3 LF1LF1 LF1LF1LF1LF1LF1LF1LF1 CFB LF4LF1LF1LF3LF1LF1LF1LF1LF1LF1LF1LF1LF1CFBLF4LF1LF1CFBLF4 CFBC1LF5LF1LF1 LF4LF4 LF5LF5LF1 LF1LF1LF1LF1LF1LF1 LF1 LF1 LF1 LF1 LF1LF1 LF1DNUPLF1 LF1 LF1 LF1 LF1LF1 LF1 LF1 LF1 LF3 CFB LF1 LF1 LF4LF1LF1 LF1LF1LF1LF1LF1LF1 LF1 LF3 CFB LF1LF1 LF4LF1LF1 LF1LF1LF1LF1LF1 LF1 LF1 LF3 CFB LF1LF1 LF4 LF1LF1LF1LF1LF1LF1LF1LF1LF1LF3CFBLF1LF1LF4NAC S UNIT C2 14 UNIT C1 16 UNIT A1 17 UNIT A1 18 UNIT A1 19 UNIT B3 20 UNIT A1 21 UNIT B1 22 UNIT A1 23 UNIT B1 34 UNIT B1 35 UNIT B2 36 3 / E403 1 / E403 1 / E401 1 / E401 1 / E401 1 / E401 1 / E401 2 / E402 2 / E402 2 / E402 DATA 202 ELECTRICAL 203 HP2 MECH 406 MECH 407 2 / E401 3 / E402 1 / E401 1 / E402 UNIT A1 94UNIT A1 93 FCU-4 FCU-4 HP2-25 1 1 HP2-31 HP2-31 HP2-31 HP2-31 HP2-31 HP2-31 3 HP2-14,16 3 HP2-3,5 2 GEB HP2-21 HP2-21 HP2-21 EF-2 HP2-27 4 HP2-31 HP2 -29 5 HP2-33 HP2-7 HP2-35 HP2-37 HP2-39 4 EF-2 HP2-41 HP2-25 HP2-25 1 / E401 ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET APRIL 28TH, 2021 20005THE AVANTPHASE IIEP102ASECOND FLOORELECTRICAL PLAN -AREA ACARMEL,INGENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO E-600 SERIES SHEETS FOR LOAD CENTER CIRCUIT SCHEDULES FOR EACH DWELLNG UNIT TYPE. C ALL RECEPTACLES SHOWN LOCATED ON BUILDING EXTERIOR OR ROOF SHOULD BE PROVIDED WITH IN-USE WEATHERPROOF ENCLOSURE. D ROOF TOP CONDENSING UNITS SERVING RESIDENT UNITS FED FROM ASSOCIATED APARTMENT LOAD CENTER. SEE ENLARGE UNIT PLANS IN E400 SERIES DRAWINGS FROM CIRCUIT INFORMATION. E CONTRACTOR TO PROVIDE (2) 1-1/2" MICRODUCTS (1) 3/8" SMOOTHBORE INNER DUCT WITH PULL STRINGS. F ALL DATA RECEPTACLES LOCATIONS SHOWN TO RECEIVE (2) RJ45 JACKS WITH CAT 6 CABLING UNLESS NOTED OTHERWISE. G ALL COMMUNICATION CABLE TO BE INSTALLED AND TESTED ACCORDING TO BICSI STANDARDS. REPLACE ANY CABLING THAT DOES NOT PASS TESTING PRIOR TO FINAL TERMINATIONS. H ALL FIRE STROBES TO BE 75cd UNLES NOTED OTHERWISE. I PROVIDE FLOW AND TAMPER SWITCHES FOR ALL FIRE RISERS AND STAND PIPES. COORDINATE LOCATIONS WITH FIRE SUPPRESSION SYSTEM DESIGNER. J ALL ELECTRICAL BRANCH CIRCUITS LOCATED IN EXPOSED CEILING SHALL BE INSTALLED IN EMT CONDUIT. SHEET KEYNOTES 1 PROVIDE 120V, 20A CIRCUIT FOR SMOKE DOOR HOLD OPENS. 2 PROVIDE COPPER GROUND BUS. SEE GROUND SYSTEM DETAIL ON E-501 FOR CONNECTION DETAILS. 3 PROVIDE NON-FUSED EQUIPMENT DISCONNECT SWTICH AND 208V/1PH CIRCUIT FOR FAN COIL UNIT. USE (2) #6 AND #10 GND. 4 PROVIDE 120V CONNECTION FOR ELECTRIC EXHAUST FAN. 5 PROVIDE 120V, 20A DEDICATED CIRCUIT FOR FIRE ALARM NAC PANEL. 1/8" = 1'-0" SECOND FLOOR ELECTRICAL PLAN -AREA A 1 # DESCRIPTION DATE 1 ASI-01 12/14/2020 10/11/21