HomeMy WebLinkAboutM102A - SECOND FLOOR MECHANICAL PLAN - AREA AT TEW3 EW3EW3EW3EW2bEW3EW3EW3EW3EW3B2LF3LF3CFB CFBLF1LF1LF1 LF1LF1LF1LF1LF1LF1LF1LF1LF1LF4LF4B1 CFBLF3LF3 631154LF1LF1 LF1LF1LF1LF1LF1LF1LF4LF4LF4LF1LF1LF1LF1LF1B1 CFB LF3 LF3 631154 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF4 LF4 LF4 LF1 LF1 LF1 LF1 LF1B1 CFB LF3 LF3 631154LF1 LF1 LF1LF1 LF1LF1 LF1 LF1 LF4 LF4LF4 LF1 LF1LF1LF1 LF1 A1LF3LF1LF1LF1LF1LF1LF1LF1LF1LF1CFBLF4LF1LF1A1 LF3 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 CFB LF4 LF1 LF1 B3 CFB LF5 LF5 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF4 LF4 LF4 LF1 LF1 LF1 LF1 LF1 CFB LF4 CFB C2 LF5 LF1LF1 LF4LF4 LF5 LF5 LF1 LF1 LF1 LF1 LF1 LF1LF1 LF1 LF1 LF1LF1 LF1LF1 LF1 A1 LF1 LF1LF1LF1LF1 CFB LF1LF1A1 LF3 LF1LF1 LF1LF1LF1LF1LF1LF1LF1 CFB LF4LF1LF1A1LF3LF1LF1LF1LF1LF1LF1LF1LF1LF1CFBLF4LF1LF1LF4CFBLF4 CFBC1LF5LF1LF1 LF4LF4 LF5LF5LF1 LF1LF1LF1LF1LF1LF1 LF1 LF1 LF1 LF1 LF1LF1 LF1A1a LF1 LF1 LF1 LF1 LF1LF1 LF1 LF1 LF1 LF3 CFB LF1 LF1 LF4A1a LF1LF1 LF1LF1LF1LF1LF1LF1 LF1 LF3 CFB LF1LF1 LF4A1a LF1LF1 LF1LF1LF1LF1LF1 LF1 LF1 LF3 CFB LF1LF1 LF4 A1aLF1LF1LF1LF1LF1LF1LF1LF1LF1LF3CFBLF1LF1LF4EF-2 4ø SR-2SR -2 -200 SR-2SR -2 -200 SR-2SR -2 -200 SR-2SR -2 -200 SR-2SR -2 -200 SR-2SR -2 -200 FCU-4 RG-2 RG-2 FCU-4 1 4 3 2 5 5 5 5 5 5 3 16/12 14/12 8ø 10ø 12/10 10ø 8ø ø8 ø 8 ø8 ø8 ø8 ø 8 1 2 16/12 16/12 1 / M401 1 / M402 1 / M402 3 / M402 2 / M402 1 / M401 1 / M401 1 / M401 1 / M403 1 / M402 1 / M402 1 / M401 3 / M403 1 / M401 1 / M401 125 CFM 6ø 16/12 6 110 CFM DATA 201 DATA 202 ELECTRICAL 203 6 EF-2 4ø FD 1 / M401 ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET APRIL 28TH, 2021 20005THE AVANTPHASE IIM102ASECOND FLOORMECHANICAL PLAN -AREA ACARMEL,INGENERAL NOTES A REFER TO SHEET P-000 FOR GENERAL PLUMBING NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO SHEET M500 SERIES DRAWINGS FOR MECHANICAL DETAILS. C REFER TO SHEET M600 SERIES DRAWINGS FOR MECHANICAL SCHEDULES. D COORDINATE WITH STRUCTURAL AND FRAMING PLANS PRIOR TO COMMENCING WORK. COORDINATE ALL ROUTING WITH ALL TRADES PRIOR TO FABRICATION. E SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND TYPES OF RATED CONSTRUCTION. CONSTRUCTION RATINGS ARE TO BE MAINTAINED. F SEAL ALL FLOOR, CEILING, AND WALL PENETRATIONS. USE FIRE CAULK AT RATED ASSEMBLIES AND GENERAL SEALANT ELSEWHERE. WHERE NON-METALLIC COMPONENTS LARGER THAN 4" DIA.(I.E. PVC OR CONDUIT) PENETRATES RATED ASSEMBLIES, INSTALL INTUMESCENT COLLAR. WHERE DUCTWORK LARGER THAN 4" DIA. PENETRATES RATED ASSEMBLIES, INSTALL FIRE DAMPER. G SIZE AND INSTALL REFRIGERANT PIPING AND ACCESSORIES PER MANUFACTURERS RECOMMENDATIONS. H ALL EXTERIOR VENT CAP AND VENT HOOD COLLARS TO BE VERIFIED IN SHOP DRAWINGS. I ALL FAN COIL UNITS TO BE WALL MOUNTED UNLESS OTHERWISE INDICATED. COORDINATE MOUNTING HEIGHT WITH OTHER DICIPLINES AND SPACE. J THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A SIGN ATTACHED TO THE DRYER BOW IN EACH APARTMENT. THE TAG SHALL DOCUMENT THE ASSOCIATED INSTALLED DRYER VENT AND READ AS FOLLOWS: CONNECTED VENT DUCT: STRAIGHT DUCT: X FEET, 90 DEG. ELBOW: COUNT=X, 45 DEG. ELBOW: COUNT=X. K THERMOSTATS TO BE MOUNTED 48-INCHES A.F.F. TO TOP OF SENSOR, OR ALIGNED WITH ADJACENT SWITCHES UNLESS OTHERWISE NOTED. L DRYER EXHAUST DUCTWORK TO BE MINIMUM 28 GAUGE. M PROVIDE MECHANICAL SYSTEMS IN COMPLIANCE WITH STATE AND LOCAL CODES. N 1/8" = 1'-0" SECOND FLOOR MECHANICAL PLAN -AREA A 1 SHEET KEYNOTES 1 FCU TO BE MOUNTED ON WALL PER MANUFACTURERS RECOMMENDATIONS ABOVE WATER HEATER. SEE DETAIL ON SHEET M501. 2 ROUTE REFRIGERANT LINES THRU WALL FROM CONDENSING UNIT ON ROOF TO FCU. COORDINATE EXACT ROUTE WITH PLUMBING LINES. ALL PENETRATIONS THROUGH RATED ASSEMBLIES ARE TO BE FIRE SEALED. 3 THERMOSTAT EQUAL TO HONEYWELL MODEL #RLV4305 TO BE MOUNTED IN THIS APPROXIMATE LOCATION 48-INCHES A.F.F. OR ALIGNED TO ADJACENT LIGHT SWITCHES. 4 ROUTE SUPPLY AIR DUCT MAIN BETWEEN TRUSSES. 5 PROVIDE CEILING RADIATION DAMPER. 6 PROVIDE WALL CAP BY BUILDER'S BEST MODEL "110113" WITH BACK-DRAFT DAMPER. FINAL COLOR TO BE DETERMINED BY ARCHITECT. TERMINATE A MINIMUM OF 3-FEET FROM ANY OPERABLE OPENING. # DESCRIPTION DATE 10/11/21