Loading...
HomeMy WebLinkAboutM102B - SECOND FLOOR MECHANICAL PLAN - AREA BEW3B1 CFB LF3 LF3 631154 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF4 LF4 LF4 LF1 LF1 LF1 LF1 LF1 B1 CFB LF3 LF3 631154LF1 LF1 LF1 LF1LF1LF1LF1LF1LF4 LF4LF4 LF1 LF1LF1LF1LF1 A1 LF3 LF1LF1 LF1LF1LF1LF1LF1LF1LF1CFBLF4LF1LF1A1 LF3 LF1LF1LF1LF1LF1LF1LF1LF1LF1 CFB LF4LF1LF1A2LF5CFBLF1LF1LF1LF1 LF1LF1 LF1LF1LF1 LF1LF1LF4CFBLF4CFBC2 LF5LF1 LF1LF4 LF4LF5LF5LF1 LF1LF1LF1 LF1LF1 LF1 LF1LF1LF1 LF1LF1 LF1LF1B1 CFB LF3 LF3 631154LF1 LF1 LF1 LF1LF1LF1LF1LF1LF4LF4LF4LF1 LF1LF1LF1LF1A1LF3LF1LF1LF1LF1LF1LF4B1 CFB LF3 LF3 631154 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF4 LF4 LF4 LF1 LF1 LF1 LF1 LF1 B1 CFB LF3 LF3 631154 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF4 LF4 LF4 LF1 LF1 LF1 LF1 LF1 A1a LF1LF1LF1LF1LF1LF1LF1LF1LF1LF3 CFB LF1LF1LF4A1a LF1 LF1 LF1 LF1 LF1LF1 LF1 LF1 LF1 LF3 CFB LF1 LF1 LF4 SR-2SR -2 -200 SR-2SR -2 -200 SR-2SR -2 -200 SR-2SR -2 -200 1 1 1 1 12/10 10ø 8øø 8 ø 8 ø 8 ø8 1 / M402 1 / M402 1 / M401 1 / M402 3 / M403 1 / M401 1 / M4021 / M4011 / M4021 / M401 4 / M401 FD 6 M404 ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET APRIL 28TH, 2021 20005THE AVANTPHASE IIM102BSECOND FLOORMECHANICAL PLAN -AREA BCARMEL,INGENERAL NOTES A REFER TO SHEET P-000 FOR GENERAL PLUMBING NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO SHEET M500 SERIES DRAWINGS FOR MECHANICAL DETAILS. C REFER TO SHEET M600 SERIES DRAWINGS FOR MECHANICAL SCHEDULES. D COORDINATE WITH STRUCTURAL AND FRAMING PLANS PRIOR TO COMMENCING WORK. COORDINATE ALL ROUTING WITH ALL TRADES PRIOR TO FABRICATION. E SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND TYPES OF RATED CONSTRUCTION. CONSTRUCTION RATINGS ARE TO BE MAINTAINED. F SEAL ALL FLOOR, CEILING, AND WALL PENETRATIONS. USE FIRE CAULK AT RATED ASSEMBLIES AND GENERAL SEALANT ELSEWHERE. WHERE NON-METALLIC COMPONENTS LARGER THAN 4" DIA.(I.E. PVC OR CONDUIT) PENETRATES RATED ASSEMBLIES, INSTALL INTUMESCENT COLLAR. WHERE DUCTWORK LARGER THAN 4" DIA. PENETRATES RATED ASSEMBLIES, INSTALL FIRE DAMPER. G SIZE AND INSTALL REFRIGERANT PIPING AND ACCESSORIES PER MANUFACTURERS RECOMMENDATIONS. H ALL EXTERIOR VENT CAP AND VENT HOOD COLLARS TO BE VERIFIED IN SHOP DRAWINGS. I ALL FAN COIL UNITS TO BE WALL MOUNTED UNLESS OTHERWISE INDICATED. COORDINATE MOUNTING HEIGHT WITH OTHER DICIPLINES AND SPACE. J THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A SIGN ATTACHED TO THE DRYER BOW IN EACH APARTMENT. THE TAG SHALL DOCUMENT THE ASSOCIATED INSTALLED DRYER VENT AND READ AS FOLLOWS: CONNECTED VENT DUCT: STRAIGHT DUCT: X FEET, 90 DEG. ELBOW: COUNT=X, 45 DEG. ELBOW: COUNT=X. K THERMOSTATS TO BE MOUNTED 48-INCHES A.F.F. TO TOP OF SENSOR, OR ALIGNED WITH ADJACENT SWITCHES UNLESS OTHERWISE NOTED. L DRYER EXHAUST DUCTWORK TO BE MINIMUM 28 GAUGE. M PROVIDE MECHANICAL SYSTEMS IN COMPLIANCE WITH STATE AND LOCAL CODES. N 1/8" = 1'-0" SECOND FLOOR MECHANICAL PLAN -AREA B 1 SHEET KEYNOTES 1 PROVIDE CEILING RADIATION DAMPER. # DESCRIPTION DATE 10/11/21