Loading...
HomeMy WebLinkAboutM105A - ROOF MECHANICAL PLAN - AREA ATALLCEILINGOVERFRAMINGROOF SLOPE 1/4" PER FT MIN CU-1 CU-1 CU-3 CU-3 CU-3 CU-3 CU-2 CU-2 CU-2 CU-1 CU-1 CU-1 CU-1 CU-2 CU-2 CU-2 CU-1 CU-1 CU-1 CU-1 CU-4 CU-4 CU-4 CU-2 CU-2 CU-2 CU-1 CU-1 CU-1 CU-2 CU-2 CU-2 CU-5 CU-1 CU-1 CU-1 CU-4 CU-4 CU-4 CU-4 CU-4 CU-1 CU-1 CU-1 CU-2 CU-2 CU-2 CU-2 CU-1 CU-1 CU-1 CU-1 CU-1 CU-1 CU-1 HP-1 10' - 0" 2 1 10' - 0"2 CU-1 CU-1 CU-3 CU-3 CU-3 CU-3 CU-1 CU-1 CU-1 CU-1 ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET APRIL 28TH, 2021 20005THE AVANTPHASE IIM105AROOF MECHANICALPLAN - AREA ACARMEL,INN 1/8" = 1'-0" ROOF MECHANICAL PLAN -AREA A 1 GENERAL NOTES A REFER TO SHEET P-000 FOR GENERAL PLUMBING NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO SHEET M500 SERIES DRAWINGS FOR MECHANICAL DETAILS. C REFER TO SHEET M600 SERIES DRAWINGS FOR MECHANICAL SCHEDULES. D COORDINATE WITH STRUCTURAL AND FRAMING PLANS PRIOR TO COMMENCING WORK. COORDINATE ALL ROUTING WITH ALL TRADES PRIOR TO FABRICATION. E SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND TYPES OF RATED CONSTRUCTION. CONSTRUCTION RATINGS ARE TO BE MAINTAINED. F SEAL ALL FLOOR, CEILING, AND WALL PENETRATIONS. USE FIRE CAULK AT RATED ASSEMBLIES AND GENERAL SEALANT ELSEWHERE. WHERE NON-METALLIC COMPONENTS LARGER THAN 4" DIA.(I.E. PVC OR CONDUIT) PENETRATES RATED ASSEMBLIES, INSTALL INTUMESCENT COLLAR. WHERE DUCTWORK LARGER THAN 4" DIA. PENETRATES RATED ASSEMBLIES, INSTALL FIRE DAMPER. G SIZE AND INSTALL REFRIGERANT PIPING AND ACCESSORIES PER MANUFACTURERS RECOMMENDATIONS. H ALL EXTERIOR VENT CAP AND VENT HOOD COLLARS TO BE VERIFIED IN SHOP DRAWINGS. I ALL FAN COIL UNITS TO BE WALL MOUNTED UNLESS OTHERWISE INDICATED. COORDINATE MOUNTING HEIGHT WITH OTHER DICIPLINES AND SPACE. J THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A SIGN ATTACHED TO THE DRYER BOW IN EACH APARTMENT. THE TAG SHALL DOCUMENT THE ASSOCIATED INSTALLED DRYER VENT AND READ AS FOLLOWS: CONNECTED VENT DUCT: STRAIGHT DUCT: X FEET, 90 DEG. ELBOW: COUNT=X, 45 DEG. ELBOW: COUNT=X. K THERMOSTATS TO BE MOUNTED 48-INCHES A.F.F. TO TOP OF SENSOR, OR ALIGNED WITH ADJACENT SWITCHES UNLESS OTHERWISE NOTED. L DRYER EXHAUST DUCTWORK TO BE MINIMUM 28 GAUGE. M PROVIDE MECHANICAL SYSTEMS IN COMPLIANCE WITH STATE AND LOCAL CODES. SHEET KEYNOTES 1 INSTALL UNIT ON PRE-FABRICATED PAD ON ROOF. TYPICAL FOR ALL UNITS IN VIEW. 2 DO NOT TERMINATE SANITARY VENT WITHIN A 10' RADIUS OF AIR INTAKE. # DESCRIPTION DATE 10/11/21