HomeMy WebLinkAboutM105A - ROOF MECHANICAL PLAN - AREA ATALLCEILINGOVERFRAMINGROOF SLOPE
1/4" PER FT MIN
CU-1 CU-1
CU-3 CU-3
CU-3 CU-3
CU-2
CU-2 CU-2
CU-1 CU-1
CU-1 CU-1
CU-2
CU-2 CU-2
CU-1 CU-1
CU-1 CU-1
CU-4
CU-4 CU-4
CU-2
CU-2 CU-2
CU-1 CU-1
CU-1
CU-2
CU-2 CU-2
CU-5 CU-1
CU-1 CU-1
CU-4 CU-4
CU-4
CU-4 CU-4
CU-1 CU-1
CU-1
CU-2 CU-2
CU-2 CU-2
CU-1 CU-1
CU-1
CU-1 CU-1
CU-1 CU-1
HP-1
10' - 0"
2
1
10' - 0"2
CU-1 CU-1 CU-3 CU-3 CU-3 CU-3
CU-1
CU-1 CU-1
CU-1 ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET
APRIL 28TH, 2021
20005THE AVANTPHASE IIM105AROOF MECHANICALPLAN - AREA ACARMEL,INN
1/8" = 1'-0"
ROOF MECHANICAL PLAN -AREA A 1
GENERAL NOTES
A REFER TO SHEET P-000 FOR GENERAL PLUMBING NOTES, SYMBOLS AND
ABBREVIATIONS.
B REFER TO SHEET M500 SERIES DRAWINGS FOR MECHANICAL DETAILS.
C REFER TO SHEET M600 SERIES DRAWINGS FOR MECHANICAL SCHEDULES.
D COORDINATE WITH STRUCTURAL AND FRAMING PLANS PRIOR TO
COMMENCING WORK. COORDINATE ALL ROUTING WITH ALL TRADES PRIOR TO
FABRICATION.
E SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND TYPES OF RATED
CONSTRUCTION. CONSTRUCTION RATINGS ARE TO BE MAINTAINED.
F SEAL ALL FLOOR, CEILING, AND WALL PENETRATIONS. USE FIRE CAULK AT
RATED ASSEMBLIES AND GENERAL SEALANT ELSEWHERE. WHERE
NON-METALLIC COMPONENTS LARGER THAN 4" DIA.(I.E. PVC OR CONDUIT)
PENETRATES RATED ASSEMBLIES, INSTALL INTUMESCENT COLLAR. WHERE
DUCTWORK LARGER THAN 4" DIA. PENETRATES RATED ASSEMBLIES, INSTALL
FIRE DAMPER.
G SIZE AND INSTALL REFRIGERANT PIPING AND ACCESSORIES PER
MANUFACTURERS RECOMMENDATIONS.
H ALL EXTERIOR VENT CAP AND VENT HOOD COLLARS TO BE VERIFIED IN SHOP
DRAWINGS.
I ALL FAN COIL UNITS TO BE WALL MOUNTED UNLESS OTHERWISE INDICATED.
COORDINATE MOUNTING HEIGHT WITH OTHER DICIPLINES AND SPACE.
J THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A SIGN
ATTACHED TO THE DRYER BOW IN EACH APARTMENT. THE TAG SHALL
DOCUMENT THE ASSOCIATED INSTALLED DRYER VENT AND READ AS
FOLLOWS: CONNECTED VENT DUCT: STRAIGHT DUCT: X FEET, 90 DEG. ELBOW:
COUNT=X, 45 DEG. ELBOW: COUNT=X.
K THERMOSTATS TO BE MOUNTED 48-INCHES A.F.F. TO TOP OF
SENSOR, OR ALIGNED WITH ADJACENT SWITCHES UNLESS
OTHERWISE NOTED.
L DRYER EXHAUST DUCTWORK TO BE MINIMUM 28 GAUGE.
M PROVIDE MECHANICAL SYSTEMS IN COMPLIANCE WITH STATE
AND LOCAL CODES.
SHEET KEYNOTES
1 INSTALL UNIT ON PRE-FABRICATED PAD ON ROOF. TYPICAL FOR ALL UNITS IN
VIEW.
2 DO NOT TERMINATE SANITARY VENT WITHIN A 10' RADIUS OF AIR INTAKE.
# DESCRIPTION DATE
10/11/21