HomeMy WebLinkAboutM401 - ENLARGED MECHANICAL PLANSLF3 LF1LF1 LF1 LF1 LF1 LF1 LF1 LF1 CFB LF4 LF1 LF1 T LF1LF1 LF1 LF1LF1 LF1 LF1 LF1 LF3 CFB LF1 LF1 LF4 T T LF5 CFB A2 LF1 LF1 LF1 LF1LF1 LF1LF1 LF1 LF1 LF1 LF1 LF4 T 6 SR-2SR -2 -200 6 SR-2SR -2 -150 SR-1SR -1 -50 6 6 SR-2SR -2 -200 1 2 4 FCU-1 12/10 3 RG-1 7 9 EF-1 4ø 9 5 4ø ø8 ø8 ø6 ø8 8 6 SR-2SR -2 -200 6 SR-2SR -2 -150 SR-1SR -1 -50 6 6 SR-2SR -2 -200 1 2 4 FCU-1 12/10 3 RG-1 7 9 EF-1 4ø 9 5 4ø ø8 ø8 ø6 ø8 8 2 4 5 6 7 8 9 EF-1 SR-1SR -1 -50 6 6 6 9 SR-2SR -2 -150 SR-2SR -2 -200 SR-1SR -1 -100 ø8 ø 8 ø 6 ø6 4ø 12/10 3 1 FCU-1 RG-1 ø6 SR-1SR -1 -100 6 2 4 6 7 8 EF-1 SR-1SR -1 -50 6 6 6 SR-2SR -2 -150 SR-2SR -2 -150 SR-1SR -1 -100 ø8 ø 8 ø 6 ø6 4ø 12/10 3 1FCU-1 RG-1 ø 6 SR-1SR -1 -100 6 SR-1SR -1 -50 6 ø6 9 5 9 4ø ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET APRIL 28TH, 2021 20005THE AVANTPHASE IIM401ENLARGEDMECHANICAL PLANSCARMEL,INGENERAL NOTES A REFER TO SHEET P-000 FOR GENERAL PLUMBING NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO SHEET M500 SERIES DRAWINGS FOR MECHANICAL DETAILS. C REFER TO SHEET M600 SERIES DRAWINGS FOR MECHANICAL SCHEDULES. D COORDINATE WITH STRUCTURAL AND FRAMING PLANS PRIOR TO COMMENCING WORK. COORDINATE ALL ROUTING WITH ALL TRADES PRIOR TO FABRICATION. E SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND TYPES OF RATED CONSTRUCTION. CONSTRUCTION RATINGS ARE TO BE MAINTAINED. F SEAL ALL FLOOR, CEILING, AND WALL PENETRATIONS. USE FIRE CAULK AT RATED ASSEMBLIES AND GENERAL SEALANT ELSEWHERE. WHERE NON-METALLIC COMPONENTS LARGER THAN 4" DIA.(I.E. PVC OR CONDUIT) PENETRATES RATED ASSEMBLIES, INSTALL INTUMESCENT COLLAR. WHERE DUCTWORK LARGER THAN 4" DIA. PENETRATES RATED ASSEMBLIES, INSTALL FIRE DAMPER. G SIZE AND INSTALL REFRIGERANT PIPING AND ACCESSORIES PER MANUFACTURERS RECOMMENDATIONS. H ALL EXTERIOR VENT CAP AND VENT HOOD COLLARS TO BE VERIFIED IN SHOP DRAWINGS. I ALL FAN COIL UNITS TO BE WALL MOUNTED UNLESS OTHERWISE INDICATED. COORDINATE MOUNTING HEIGHT WITH OTHER DICIPLINES AND SPACE. J THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A SIGN ATTACHED TO THE DRYER BOW IN EACH APARTMENT. THE TAG SHALL DOCUMENT THE ASSOCIATED INSTALLED DRYER VENT AND READ AS FOLLOWS: CONNECTED VENT DUCT: STRAIGHT DUCT: X FEET, 90 DEG. ELBOW: COUNT=X, 45 DEG. ELBOW: COUNT=X. K THERMOSTATS TO BE MOUNTED 48-INCHES A.F.F. TO TOP OF SENSOR, OR ALIGNED WITH ADJACENT SWITCHES UNLESS OTHERWISE NOTED. L DRYER EXHAUST DUCTWORK TO BE MINIMUM 28 GAUGE. M PROVIDE MECHANICAL SYSTEMS IN COMPLIANCE WITH STATE AND LOCAL CODES. SHEET KEYNOTES 1 FCU TO BE MOUNTED ON WALL PER MANUFACTURERS RECOMMENDATIONS ABOVE WATER HEATER. SEE DETAIL ON SHEET M501. 2 ROUTE REFRIGERANT LINES THRU WALL FROM CONDENSING UNIT ON ROOF TO FCU. COORDINATE EXACT ROUTE WITH PLUMBING LINES. ALL PENETRATIONS THROUGH RATED ASSEMBLIES ARE TO BE FIRE SEALED. 3 RETURN AIR GRILLE OVER DOOR. 4 ROUTE SUPPLY AIR DUCT MAIN BETWEEN TRUSSES. 5 DRYER VENT BOX TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS. MOUNT ON WALL APPROXIMATELY 4' A.F.F. SEE DETAIL ON M-501. 6 PROVIDE CEILING RADIATION DAMPER. 7 INSTALL EXHAUST FAN IN WALL 7' A.F.F. PER MANUFACTURERS RECOMMENDATIONS. 8 THERMOSTAT EQUAL TO HONEYWELL MODEL #RLV4305 TO BE MOUNTED IN THIS APPROXIMATE LOCATION 48-INCHES ABOVE A.F.F. OR ALIGNED TO ADJACENT LIGHT SWITCHES. 9 PROVIDE WALL CAP BY BUILDER'S BEST MODEL "110113" WITH BACK-DRAFT DAMPER. FINAL COLOR TO BE DETERMINED BY ARCHITECT. TERMINATE A MINIMUM OF 3-FEET FROM ANY OPERABLE OPENING. 1/4" = 1'-0" ENLARGED UNIT A1 MECHANICAL PLAN 1 1/4" = 1'-0" ENLARGED UNIT A1a MECHANICAL PLAN2 1/4" = 1'-0" ENLARGED UNIT A1b MECHANICAL PLAN3 1/4" = 1'-0" ENLARGED UNIT A2 MECHANICAL PLAN4 # DESCRIPTION DATE 10/11/21