HomeMy WebLinkAboutM401 - ENLARGED MECHANICAL PLANSLF3
LF1LF1
LF1
LF1
LF1
LF1
LF1
LF1
CFB
LF4
LF1
LF1 T
LF1LF1
LF1
LF1LF1
LF1
LF1
LF1
LF3
CFB
LF1
LF1
LF4
T
T
LF5
CFB
A2
LF1
LF1
LF1 LF1LF1
LF1LF1
LF1
LF1
LF1
LF1
LF4
T
6 SR-2SR -2 -200
6 SR-2SR -2 -150
SR-1SR -1 -50
6
6
SR-2SR -2 -200
1
2
4
FCU-1
12/10
3
RG-1
7
9
EF-1
4ø
9
5
4ø
ø8
ø8
ø6
ø8
8
6 SR-2SR -2 -200
6 SR-2SR -2 -150
SR-1SR -1 -50
6
6
SR-2SR -2 -200
1
2
4
FCU-1
12/10
3
RG-1
7
9
EF-1
4ø
9
5
4ø
ø8
ø8
ø6
ø8
8
2
4
5
6
7
8
9
EF-1
SR-1SR -1 -50
6
6
6
9
SR-2SR -2 -150
SR-2SR -2 -200
SR-1SR -1 -100
ø8 ø 8
ø 6
ø6
4ø
12/10 3
1 FCU-1
RG-1
ø6
SR-1SR -1 -100
6
2
4
6
7
8
EF-1
SR-1SR -1 -50
6
6
6
SR-2SR -2 -150
SR-2SR -2 -150
SR-1SR -1 -100
ø8
ø 8
ø 6
ø6
4ø
12/10
3
1FCU-1
RG-1
ø 6
SR-1SR -1 -100
6
SR-1SR -1 -50
6
ø6
9
5
9
4ø ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET
APRIL 28TH, 2021
20005THE AVANTPHASE IIM401ENLARGEDMECHANICAL PLANSCARMEL,INGENERAL NOTES
A REFER TO SHEET P-000 FOR GENERAL PLUMBING NOTES, SYMBOLS AND
ABBREVIATIONS.
B REFER TO SHEET M500 SERIES DRAWINGS FOR MECHANICAL DETAILS.
C REFER TO SHEET M600 SERIES DRAWINGS FOR MECHANICAL SCHEDULES.
D COORDINATE WITH STRUCTURAL AND FRAMING PLANS PRIOR TO
COMMENCING WORK. COORDINATE ALL ROUTING WITH ALL TRADES PRIOR TO
FABRICATION.
E SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND TYPES OF RATED
CONSTRUCTION. CONSTRUCTION RATINGS ARE TO BE MAINTAINED.
F SEAL ALL FLOOR, CEILING, AND WALL PENETRATIONS. USE FIRE CAULK AT
RATED ASSEMBLIES AND GENERAL SEALANT ELSEWHERE. WHERE
NON-METALLIC COMPONENTS LARGER THAN 4" DIA.(I.E. PVC OR CONDUIT)
PENETRATES RATED ASSEMBLIES, INSTALL INTUMESCENT COLLAR. WHERE
DUCTWORK LARGER THAN 4" DIA. PENETRATES RATED ASSEMBLIES, INSTALL
FIRE DAMPER.
G SIZE AND INSTALL REFRIGERANT PIPING AND ACCESSORIES PER
MANUFACTURERS RECOMMENDATIONS.
H ALL EXTERIOR VENT CAP AND VENT HOOD COLLARS TO BE VERIFIED IN SHOP
DRAWINGS.
I ALL FAN COIL UNITS TO BE WALL MOUNTED UNLESS OTHERWISE INDICATED.
COORDINATE MOUNTING HEIGHT WITH OTHER DICIPLINES AND SPACE.
J THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A SIGN
ATTACHED TO THE DRYER BOW IN EACH APARTMENT. THE TAG SHALL
DOCUMENT THE ASSOCIATED INSTALLED DRYER VENT AND READ AS
FOLLOWS: CONNECTED VENT DUCT: STRAIGHT DUCT: X FEET, 90 DEG. ELBOW:
COUNT=X, 45 DEG. ELBOW: COUNT=X.
K THERMOSTATS TO BE MOUNTED 48-INCHES A.F.F. TO TOP OF
SENSOR, OR ALIGNED WITH ADJACENT SWITCHES UNLESS
OTHERWISE NOTED.
L DRYER EXHAUST DUCTWORK TO BE MINIMUM 28 GAUGE.
M PROVIDE MECHANICAL SYSTEMS IN COMPLIANCE WITH STATE
AND LOCAL CODES.
SHEET KEYNOTES
1 FCU TO BE MOUNTED ON WALL PER MANUFACTURERS RECOMMENDATIONS
ABOVE WATER HEATER. SEE DETAIL ON SHEET M501.
2 ROUTE REFRIGERANT LINES THRU WALL FROM CONDENSING UNIT ON ROOF
TO FCU. COORDINATE EXACT ROUTE WITH PLUMBING LINES. ALL
PENETRATIONS THROUGH RATED ASSEMBLIES ARE TO BE FIRE SEALED.
3 RETURN AIR GRILLE OVER DOOR.
4 ROUTE SUPPLY AIR DUCT MAIN BETWEEN TRUSSES.
5 DRYER VENT BOX TO BE INSTALLED PER MANUFACTURERS
RECOMMENDATIONS. MOUNT ON WALL APPROXIMATELY 4' A.F.F. SEE DETAIL
ON M-501.
6 PROVIDE CEILING RADIATION DAMPER.
7 INSTALL EXHAUST FAN IN WALL 7' A.F.F. PER MANUFACTURERS
RECOMMENDATIONS.
8 THERMOSTAT EQUAL TO HONEYWELL MODEL #RLV4305 TO BE MOUNTED IN
THIS APPROXIMATE LOCATION 48-INCHES
ABOVE A.F.F. OR ALIGNED TO ADJACENT LIGHT SWITCHES.
9 PROVIDE WALL CAP BY BUILDER'S BEST MODEL "110113" WITH BACK-DRAFT
DAMPER. FINAL COLOR TO BE DETERMINED BY ARCHITECT. TERMINATE A
MINIMUM OF 3-FEET FROM ANY OPERABLE OPENING.
1/4" = 1'-0"
ENLARGED UNIT A1 MECHANICAL PLAN 1
1/4" = 1'-0"
ENLARGED UNIT A1a MECHANICAL PLAN2
1/4" = 1'-0"
ENLARGED UNIT A1b MECHANICAL PLAN3
1/4" = 1'-0"
ENLARGED UNIT A2 MECHANICAL PLAN4
# DESCRIPTION DATE
10/11/21