HomeMy WebLinkAboutM402 - ENLARGED MECHANICAL PLANSCFB
LF3
LF3
LF1
LF1LF1
LF1
LF1
LF1
LF1
LF1
LF4
LF4
LF4
LF1
LF1
LF1
LF1
T
T
LF3
LF3
CFB
CFB
LF1
LF1
LF1 LF1
LF1
LF1
LF1
LF1
LF1
LF1
LF1
LF4
LF4
CFB
LF5
LF5
B3
LF1
LF1 LF1LF1
LF1
LF1
LF1
LF1
LF1
LF1
LF4
LF4
LF4
LF1
LF1 LF1
T
9
12
3
4
RG-1
14/12
FCU-2
6 SR-2SR -2 -150
6 SR-2SR -2 -200 6 SR-2SR -2 -150
SR-1SR -1 -50
6
SR-1SR -1 -50
6
6
SR-1SR -1 -50
6
SR-2SR -2 -150
7
5
4ø
ø8
ø8
ø8
ø 6
ø6
ø8
ø6
7
EF-1
4ø
9
8
EF-1
4ø
5
9
4ø
4ø
6 SR-2SR -2 -150
SR-2SR -2 -150
SR-2SR -2 -150
6
6
SR-1SR -1 -50
6
EF-1
7
6
SR-1SR -1 -50
6
SR-2SR -2 -150
1
2
4
FCU-2 3
RG-1
7 9
EF-1
4ø
8
ø6
14/12
ø 8
ø8
ø8
ø6
ø8
1
2
3
414/12
FCU-2
RG-1
6 SR-2SR -2 -150
6 SR-2SR -2 -150
6 SR-2SR -2 -150
SR-1SR -1 -50
6
EF-1
6
SR-1SR -1 -50
EF-1
7
SR-1SR -1 -50
6
6
6
SR-1SR -1 -100
SR-1SR -1 -100
8
9
7
4ø
4ø
6ø
10
ø6
ø6
ø 6
ø 8 ø 8 ø 6
ø6
ø8
5
4ø ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET
APRIL 28TH, 2021
20005THE AVANTPHASE IIM402ENLARGEDMECHANICAL PLANSCARMEL,INGENERAL NOTES
A REFER TO SHEET P-000 FOR GENERAL PLUMBING NOTES, SYMBOLS AND
ABBREVIATIONS.
B REFER TO SHEET M500 SERIES DRAWINGS FOR MECHANICAL DETAILS.
C REFER TO SHEET M600 SERIES DRAWINGS FOR MECHANICAL SCHEDULES.
D COORDINATE WITH STRUCTURAL AND FRAMING PLANS PRIOR TO
COMMENCING WORK. COORDINATE ALL ROUTING WITH ALL TRADES PRIOR TO
FABRICATION.
E SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND TYPES OF RATED
CONSTRUCTION. CONSTRUCTION RATINGS ARE TO BE MAINTAINED.
F SEAL ALL FLOOR, CEILING, AND WALL PENETRATIONS. USE FIRE CAULK AT
RATED ASSEMBLIES AND GENERAL SEALANT ELSEWHERE. WHERE
NON-METALLIC COMPONENTS LARGER THAN 4" DIA.(I.E. PVC OR CONDUIT)
PENETRATES RATED ASSEMBLIES, INSTALL INTUMESCENT COLLAR. WHERE
DUCTWORK LARGER THAN 4" DIA. PENETRATES RATED ASSEMBLIES, INSTALL
FIRE DAMPER.
G SIZE AND INSTALL REFRIGERANT PIPING AND ACCESSORIES PER
MANUFACTURERS RECOMMENDATIONS.
H ALL EXTERIOR VENT CAP AND VENT HOOD COLLARS TO BE VERIFIED IN SHOP
DRAWINGS.
I ALL FAN COIL UNITS TO BE WALL MOUNTED UNLESS OTHERWISE INDICATED.
COORDINATE MOUNTING HEIGHT WITH OTHER DICIPLINES AND SPACE.
J THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A SIGN
ATTACHED TO THE DRYER BOW IN EACH APARTMENT. THE TAG SHALL
DOCUMENT THE ASSOCIATED INSTALLED DRYER VENT AND READ AS
FOLLOWS: CONNECTED VENT DUCT: STRAIGHT DUCT: X FEET, 90 DEG. ELBOW:
COUNT=X, 45 DEG. ELBOW: COUNT=X.
K THERMOSTATS TO BE MOUNTED 48-INCHES A.F.F. TO TOP OF
SENSOR, OR ALIGNED WITH ADJACENT SWITCHES UNLESS
OTHERWISE NOTED.
L DRYER EXHAUST DUCTWORK TO BE MINIMUM 28 GAUGE.
M PROVIDE MECHANICAL SYSTEMS IN COMPLIANCE WITH STATE
AND LOCAL CODES.
1/4" = 1'-0"
ENLARGED UNIT B1 MECHANICAL PLAN 1
1/4" = 1'-0"
ENLARGED UNIT B2 MECHANICAL PLAN2
SHEET KEYNOTES
1 FCU TO BE MOUNTED ON WALL PER MANUFACTURERS RECOMMENDATIONS
ABOVE WATER HEATER. SEE DETAIL ON SHEET M501.
2 ROUTE REFRIGERANT LINES THRU WALL FROM CONDENSING UNIT ON ROOF
TO FCU. COORDINATE EXACT ROUTE WITH PLUMBING LINES. ALL
PENETRATIONS THROUGH RATED ASSEMBLIES ARE TO BE FIRE SEALED.
3 RETURN AIR GRILLE OVER DOOR.
4 ROUTE SUPPLY AIR DUCT MAIN BETWEEN TRUSSES.
5 DRYER VENT BOX TO BE INSTALLED PER MANUFACTURERS
RECOMMENDATIONS. MOUNT ON WALL APPROXIMATELY 4' A.F.F. SEE DETAIL
ON M-501.
6 PROVIDE CEILING RADIATION DAMPER.
7 INSTALL EXHAUST FAN IN WALL 7' A.F.F. PER MANUFACTURERS
RECOMMENDATIONS.
8 THERMOSTAT EQUAL TO HONEYWELL MODEL #RLV4305 TO BE MOUNTED IN
THIS APPROXIMATE LOCATION 48-INCHES
ABOVE A.F.F. OR ALIGNED TO ADJACENT LIGHT SWITCHES.
9 PROVIDE WALL CAP BY BUILDER'S BEST MODEL "110113" WITH BACK-DRAFT
DAMPER. FINAL COLOR TO BE DETERMINED BY ARCHITECT. TERMINATE A
MINIMUM OF 3-FEET FROM ANY OPERABLE OPENING.
10 PROVIDE WALL CAP BY BUILDER'S BEST MODEL "111777" WITH BACK-DRAFT
DAMPER. FINAL COLOR TO BE DETERMINED BY ARCHITECT. TERMINATE A
MINIMUM OF 3-FEET FROM ANY OPERABLE OPENING.
1/4" = 1'-0"
ENLARGED UNIT B3 MECHANICAL PLAN3
# DESCRIPTION DATE
1 ASI-01 12/14/2020
10/11/21