HomeMy WebLinkAboutM402 - ENLARGED MECHANICAL PLANSCFB LF3 LF3 LF1 LF1LF1 LF1 LF1 LF1 LF1 LF1 LF4 LF4 LF4 LF1 LF1 LF1 LF1 T T LF3 LF3 CFB CFB LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF4 LF4 CFB LF5 LF5 B3 LF1 LF1 LF1LF1 LF1 LF1 LF1 LF1 LF1 LF1 LF4 LF4 LF4 LF1 LF1 LF1 T 9 12 3 4 RG-1 14/12 FCU-2 6 SR-2SR -2 -150 6 SR-2SR -2 -200 6 SR-2SR -2 -150 SR-1SR -1 -50 6 SR-1SR -1 -50 6 6 SR-1SR -1 -50 6 SR-2SR -2 -150 7 5 4ø ø8 ø8 ø8 ø 6 ø6 ø8 ø6 7 EF-1 4ø 9 8 EF-1 4ø 5 9 4ø 4ø 6 SR-2SR -2 -150 SR-2SR -2 -150 SR-2SR -2 -150 6 6 SR-1SR -1 -50 6 EF-1 7 6 SR-1SR -1 -50 6 SR-2SR -2 -150 1 2 4 FCU-2 3 RG-1 7 9 EF-1 4ø 8 ø6 14/12 ø 8 ø8 ø8 ø6 ø8 1 2 3 414/12 FCU-2 RG-1 6 SR-2SR -2 -150 6 SR-2SR -2 -150 6 SR-2SR -2 -150 SR-1SR -1 -50 6 EF-1 6 SR-1SR -1 -50 EF-1 7 SR-1SR -1 -50 6 6 6 SR-1SR -1 -100 SR-1SR -1 -100 8 9 7 4ø 4ø 6ø 10 ø6 ø6 ø 6 ø 8 ø 8 ø 6 ø6 ø8 5 4ø ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET APRIL 28TH, 2021 20005THE AVANTPHASE IIM402ENLARGEDMECHANICAL PLANSCARMEL,INGENERAL NOTES A REFER TO SHEET P-000 FOR GENERAL PLUMBING NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO SHEET M500 SERIES DRAWINGS FOR MECHANICAL DETAILS. C REFER TO SHEET M600 SERIES DRAWINGS FOR MECHANICAL SCHEDULES. D COORDINATE WITH STRUCTURAL AND FRAMING PLANS PRIOR TO COMMENCING WORK. COORDINATE ALL ROUTING WITH ALL TRADES PRIOR TO FABRICATION. E SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND TYPES OF RATED CONSTRUCTION. CONSTRUCTION RATINGS ARE TO BE MAINTAINED. F SEAL ALL FLOOR, CEILING, AND WALL PENETRATIONS. USE FIRE CAULK AT RATED ASSEMBLIES AND GENERAL SEALANT ELSEWHERE. WHERE NON-METALLIC COMPONENTS LARGER THAN 4" DIA.(I.E. PVC OR CONDUIT) PENETRATES RATED ASSEMBLIES, INSTALL INTUMESCENT COLLAR. WHERE DUCTWORK LARGER THAN 4" DIA. PENETRATES RATED ASSEMBLIES, INSTALL FIRE DAMPER. G SIZE AND INSTALL REFRIGERANT PIPING AND ACCESSORIES PER MANUFACTURERS RECOMMENDATIONS. H ALL EXTERIOR VENT CAP AND VENT HOOD COLLARS TO BE VERIFIED IN SHOP DRAWINGS. I ALL FAN COIL UNITS TO BE WALL MOUNTED UNLESS OTHERWISE INDICATED. COORDINATE MOUNTING HEIGHT WITH OTHER DICIPLINES AND SPACE. J THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A SIGN ATTACHED TO THE DRYER BOW IN EACH APARTMENT. THE TAG SHALL DOCUMENT THE ASSOCIATED INSTALLED DRYER VENT AND READ AS FOLLOWS: CONNECTED VENT DUCT: STRAIGHT DUCT: X FEET, 90 DEG. ELBOW: COUNT=X, 45 DEG. ELBOW: COUNT=X. K THERMOSTATS TO BE MOUNTED 48-INCHES A.F.F. TO TOP OF SENSOR, OR ALIGNED WITH ADJACENT SWITCHES UNLESS OTHERWISE NOTED. L DRYER EXHAUST DUCTWORK TO BE MINIMUM 28 GAUGE. M PROVIDE MECHANICAL SYSTEMS IN COMPLIANCE WITH STATE AND LOCAL CODES. 1/4" = 1'-0" ENLARGED UNIT B1 MECHANICAL PLAN 1 1/4" = 1'-0" ENLARGED UNIT B2 MECHANICAL PLAN2 SHEET KEYNOTES 1 FCU TO BE MOUNTED ON WALL PER MANUFACTURERS RECOMMENDATIONS ABOVE WATER HEATER. SEE DETAIL ON SHEET M501. 2 ROUTE REFRIGERANT LINES THRU WALL FROM CONDENSING UNIT ON ROOF TO FCU. COORDINATE EXACT ROUTE WITH PLUMBING LINES. ALL PENETRATIONS THROUGH RATED ASSEMBLIES ARE TO BE FIRE SEALED. 3 RETURN AIR GRILLE OVER DOOR. 4 ROUTE SUPPLY AIR DUCT MAIN BETWEEN TRUSSES. 5 DRYER VENT BOX TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS. MOUNT ON WALL APPROXIMATELY 4' A.F.F. SEE DETAIL ON M-501. 6 PROVIDE CEILING RADIATION DAMPER. 7 INSTALL EXHAUST FAN IN WALL 7' A.F.F. PER MANUFACTURERS RECOMMENDATIONS. 8 THERMOSTAT EQUAL TO HONEYWELL MODEL #RLV4305 TO BE MOUNTED IN THIS APPROXIMATE LOCATION 48-INCHES ABOVE A.F.F. OR ALIGNED TO ADJACENT LIGHT SWITCHES. 9 PROVIDE WALL CAP BY BUILDER'S BEST MODEL "110113" WITH BACK-DRAFT DAMPER. FINAL COLOR TO BE DETERMINED BY ARCHITECT. TERMINATE A MINIMUM OF 3-FEET FROM ANY OPERABLE OPENING. 10 PROVIDE WALL CAP BY BUILDER'S BEST MODEL "111777" WITH BACK-DRAFT DAMPER. FINAL COLOR TO BE DETERMINED BY ARCHITECT. TERMINATE A MINIMUM OF 3-FEET FROM ANY OPERABLE OPENING. 1/4" = 1'-0" ENLARGED UNIT B3 MECHANICAL PLAN3 # DESCRIPTION DATE 1 ASI-01 12/14/2020 10/11/21