HomeMy WebLinkAboutM501 - MECHANICAL DETAILSFINISHED INTERIOR MIN. 32" SQUARE DOOR MIN. 30" WATER HEATER PAN WATER HEATER MECHANICAL EQUIPMENT PLENUM CLEARANCE CPVC CONDENSATE DRAIN W/ TRAP; ROUTE TO HUB DRAIN WITH AIR GAP MAIN SHUT-OFF WATER HEATER PAN SLEEVE FLEX CONN. FIRE DAMPER SIMILAR TO RUSKIN CFD7 FAN COIL WATER HEATER HW CW VALVE SIDE VIEW TOP VIEW NOTE: TYPICAL CONDITION SHOWN FOR UNITS, REFER TO MECHANICAL AND PLUMBING FLOOR PLANS FOR ADDITIONAL REQUIREMENTS. CEILING RADIATION DAMPER (TYP.) MIN. 20" REFRIGERANT SUCTION / LIQUID; ROUTE TO CONDENSING UNIT RETURN GRILLE, SEE PLANS SECURE AIR HANDLER TO WALL WITH Z PANEL CLIPS / HANGERS AND ANGLE BRACKETS NOTES: 1. ROUTE CONDENSATE PIPING (SIZE PER MANUFACTURER) TO HUB DRAIN. 2. REFER TO REFRIGERANT PIPING DETAIL ON MECHANICAL DETAIL SHEET FOR ASSOCIATED REQUIREMENTS. 3. REFER TO STRUTURAL UNIT PLAN DRAWINGS FOR ACTUAL CONDITION AT EACH CLOSET. HARD DUCT MAIN ALWAYS ROUTES PARALLEL TO JOISTS. 4. COORDINATE HARD DUCT ELEVATION AT JOIST SPACE WITH FIRE AND PLUMBING PIPING PRIOR TO INSTALLATION. 5. FIRESTOP ALL PENETRATIONS AT CEILING AND FLOOR. 6. ALL MATERIALS CONTAINED WITHIN MECHANICAL CLOSET MUST HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. SPECIFICATION FOR JOINING AND ATTACHING FLEXIBLE DUCT DUCTWORK FLEXIBLE DUCT-MAXIMUM 6'-0" LENGTH AND NO MORE THAN TWO (2) 90° BENDS. SQUARE TO ROUND FITTING CEILINGAIR TERMINAL WITH INTEGRAL BALANCE DAMPER A. METALLIC FLEXIBLE DUCT SHALL BE ATTACHED USING A MINIMUM OF THREE #8 SHEET METAL SCREWS EQUALLY SPACED AROUND THE DUCT'S CIRCUMFERENCE; DUCTS LARGER THAN 12"Ø SHALL HAVE A MINIMUM OF FIVE #8 SHEET METAL SCREWS. SCREWS SHALL BE LOCATED AT LEAST 8" FROM THE DUCT END. B. NON-METALLIC FLEXIBLE DUCT SHALL BE SECURED TO THE SLEEVE OR COLLAR USING A DRAW BAND. IF THE DUCT COLLAR EXCEEDS 12"Ø, THE DRAW BAND MUST BE POSITIONED BEHIND A BEAD ON THE METAL COLLAR. C. INSULATION AND VAPOR BARRIERS PRESENT ON FACTORY-FABRICATED DUCTS SHALL BE FITTED OVER THE CORE CONNECTION AND SHALL BE SUPPLEMENTALLY SECURED WITH A DRAW BAND. D. FLEXIBLE DUCT SEALING SHALL BE A CLASS "B" FOR LOW PRESSURE DUCT. EXTERIOR WALL LOUVER BY DIVISION 23 GROUT AROUND VOIDS IN WALL AND SEAL AROUND LOUVER WATERTIGHT WITH NON-HARDENING SILICONE CAULK (INSIDE & OUTSIDE) SEAL ALL JOINTS IN DUCT WATERTIGHT MINIMUM 24" DEEP PLENUM SLOPE DOWN FOR DRAINAGE OUTDOOR AIR INTAKE DUCT BLANK SHEETMETAL BEHIND BOTTOM FIN EXTERNAL 2" THICK INSULATION FINISHED FLOOR AS SCHEDULED LIGHTING CONTROLS, INTERCOM, PULL STATION, THERMOSTAT DOOR FRAME/WALL OPENING WHERE OCCURS LOCATE DEVICES 6" FROM DOOR/WALL OPENING, OR AS DIMENSIONED. WHERE NOT DIMENSIONED, LOCATE AT NEAREST STUD FROM LOCATION SHOWN ON FLOOR PLAN 6"UON48" UONINSTALL BOT. OF UNI NOM. 7" ABOVE CEILING, SAME AT ALL LOCATIONS EXH. VENT TERMINATION, SEE PLANS CAULK/SEAL WALL FLANGE & WATER-TIGHT SEAL, PER MFGR'S INSTR. REFER TO ARCHITECTURAL PLANS FOR WALL CONSTRUCTION WALL WALL DRYER BOX FLOOR 4"Ø ALUMINUM OR FOIL FLEX DUCT TO DRYER 4"Ø RIGID DUCT CAULK AROUND DUCT PENETRATION.RSRLEVAPORATOR COIL THERMAL EXPANSION VALVE REFER TO AIR COOLED CONDENSING UNIT SCHEDULE FOR REFRIGERANT LINE SIZES AIR COOLED CONDENSING UNIT WITH FACTORY INSTALLED: 1. LIQUID LINE FILTER DRIER 2. SUCTION AND DISCHARGE LINE REFRIGERATION CHARGING CONNECTIONS FIELD BRAZED CONNECTIONS ISOLATION VALVE, TYP. PROVIDE 16 GA. NAIL STOP WHERE LINE OR PIPE IS LESS THAN 1-1/2" FROM STUD FACE. PROVIDE 1-1/4" GAP ABOVE THE PIPE TO ACCOMODATE WOOD SHRINKAGE. PROVIDE 16 GA. NAIL STOP WHERE LINE OR PIPE IS LESS THAN 1-1/2" FROM STUD FACE. INTERIOR NON LOAD BEARING WALL STUDS EXTERIOR AND/OR LOAD BEARING WALL STUDS "N" (MAX) "D" (MAX) 40% W ( SEE NOTE 3) 40% W 25% W 40% W NOTES: 1. BORED HOLES SHALL NOT BE LOCATED AT THE SAME SECTION OF STUD AS A NOTCH. 2. PROVIDE ELONGATED HOLES SO AS TO ACCOMODATE WOOD SHRINKAGE (RE;SPECS). NOT PROVIDING A GAP BETWEEN THE STUD AND THE PIPE MAY RESULT IN DAMAGE TO THE PIPE. 3. "D" MAY BE INCREASED TO 60% OF "W" FOR TWO CONSECUTIVE NON LOAD BEARING STUDS MAXIMUM BUT STUDS MUST BE DOUBLED UP. "W" "D""N" "W" 5/8" MIN. 5/8" MIN. LINESET (1 PER SLEEVE) 3" MIN. FIRECAULK (INSIDE AND OUTSIDE SLEEVE) 3" METAL SLEEVE 20 GA MIN. TAPE CUT ENDS (TO PREVENT SHARP EDGES) FLOOR ASSEMBLY SUBFLOOR WOOD TRUSS CEILING ASSEMBLYFIRECAULK (INSIDE AND OUTSIDE PIPE) 8" MIN.2"2"GENERAL NOTES: 1. DO NOT INSTALL IN CORNERS 2. SLEEVES AT TOP FLOOR CEILING ROD 3. SLEEVES TO BE FASTENED IN PLACE BEFORE DRYWALL / LINESET INSTALL 4. MIN 8" FROM SIDEWALL AND 4" FROM BACK WALL.ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET APRIL 28TH, 2021 20005THE AVANTPHASE IIM501MECHANICAL DETAILS CARMEL,IN12" = 1'-0" MECHANICAL ROOM DETAIL 1 12" = 1'-0" TYPICAL AIR TERMINAL INSTALLATION DETAIL2 12" = 1'-0" LOUVER INSTALLATION DETAIL 23 1/2" = 1'-0" TYPICAL THERMOSTAT MOUNTING DETAIL4 12" = 1'-0" VENT TERMINAL DETAIL5 12" = 1'-0" VERTICAL DRYER EXHAUST DUCT DETAIL 6 12" = 1'-0" REFRIGERATION PIPING DETAIL 27 12" = 1'-0" NOTHCHES & BORED HOLES IN WALL STUDS DETAIL 8 12" = 1'-0" LINESET SLEEVE DETAIL9 # DESCRIPTION DATE 10/11/21