HomeMy WebLinkAboutP101A - FIRST FLOOR PLUMBING PLAN - AREA A1/A3012/A3013/A3014/A301EW3EW3EW3EW2bEW3 EW3EW33/A303UPMDBP-1 RPBP-1A
RPBP-1B
ET
DCVA-1
WATER
METERS
WHA-B
WC-2 WC-2
L-2L-2
2" FD-1 2" FD-1
SK-2
WD-1
WSB-1
2" OSD-1
WH-1
WH-1
WH-1
FCO
UNIT C2
2
UNIT C1
3
UNIT A1
4
UNIT A1
5
UNIT A1
6
UNIT B1
7
UNIT A1
8SOCIAL HUB
101
FOCUS BOOTH
104FOCUS BOOTH
105
FOCUS BOOTH
106FOCUS BOOTH
107
CONFERENCE
ROOM
103
CONFERENCE
ROOM
102
RESTROOM
108
RESTROOM
109
MAIL CENTER
111
DEMARC
116
WATER
117
UNIT A1
71
1 1
1
1
1
1
1
1
1313
2 3
2
3
2
3
13
13
13
13
13
13
2
3
2
3
2
3
13
13
2
3
23
23
2
3
2 3
4
5
4
5
4
5
12
13
4 5
12
5
4
12
5
4
12 12
12
5
4
12
5
4
12
FCO
DWH-3
TET-3
4" W4" W
4" W W14
4" W4" W
4" W W14
4" W
4" W4" W
CO
4" W WW
14
4" W 4" W
WW4" W
4" W
W
4" W
14
1/2" HW
1/2" CW
1/2" CW
1/2" CW
1/2" CW
3" FD-2
3" FD-2
1 1/2" V
1 1/2" V
1/2" HW
2" V
2" V
15
15
16
11
11
4" W4" W
4" W
W
W14
2" V
4" W
W
14
4" W
14
4" W
4" WW
14
14
10
6
9
7
8
4" FD-2
12
3" W
12
3" W
3" W
4" W
3" W
4" WWARCHITECT
CLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET
APRIL 28TH, 2021
20005THE AVANTPHASE IIP101AFIRST FLOORPLUMBING PLAN -AREA ACARMEL,INSHEET KEYNOTES
1 3/4" COLD WATER FROM ABOVE IN WALL.
2 4" WASTE STACK IN WALL.
3 4" VENT STACK IN WALL.
4 3" WASTE STACK IN WALL.
5 2" VENT STACK IN WALL.
6 WET-PIPE FIRE SUPPRESSION SYSTEM. FIRE PROTECTION CONTRACTOR TO
DESIGN, FURNISH AND INSTALL A COMPLETE FIRE SUPPRESSION SYSTEM
FOR ENTIRE BUILDING PER NFPA 13.
7 6" INCOMING FIRE SERVICE WATER LINE.
8 6" INCOMING DOMESTIC WATER SERVICE LINE.
9 4" FIRE LINE DOWN TO POINT BELOW FLOOR TO FIRE DEPARTMENT
CONNECTION (FDC). SEE SITE/CIVIL DRAWINGS FOR EXACT LOCATION.
10 4" COLD WATER UP IN CORNER INTO CHASE ABOVE.
11 3/4" COLD WATER FROM ABOVE IN WALL.
12 3" WASTE FROM ABOVE.
13 4" WASTE FROM ABOVE.
14 4" WASTE DOWN IN WALL TO POINT BELOW FLOOR SLAB.
15 1/2" COLD WATER AND 1/2" HOT WATER DROP IN WALL. 1-1/2"V RISE. 2"W
DOWN.
16 1-1/2" COLD WATER DROP IN WALL.
N
1/8" = 1'-0"
FIRST FLOOR PLUMBING PLAN -AREA A1
GENERAL NOTES
A REFER TO DRAWING P000 FOR PLUMBING AND FIRE PROTECTION SYMBOLS,
LEGENDS, ABBREVIATIONS, ADDITIONAL GENERAL NOTES AND PLUMBING
NOTES.
B REFER TO P500 SERIES DRAWINGS FOR PLUMBING DETAILS.
C REFER TO P600 SERIES DRAWINGS FOR PLUMBING SCHEDULES.
D PROVIDE CEILING ACCESS PANELS AT SHUT-OFF VALVES, CONTROL VALVES,
DRAIN VALVES, ETC. THAT ARE LOCATED ABOVE A NON-LAY-IN OR
ACCESSIBLE CEILING.
E INSTALL ALL PIPING AS HIGH AS POSSIBLE.
F ALL PIPING, INSULATION, JACKETS, COVERINGS, SEALERS, MASTICS, AND
ADHESIVES ARE TO BE PLENUM RATED WITHIN RETURN AIR PLENUMS,
HAVING A FLAME-SPREAD INDEX OF 25 OR LESS, AND A SMOKE-DEVELOPED
INDEX OF 50 OR LESS, AS REQUIRED BY CODE.
# DESCRIPTION DATE
1 ASI-01 12/14/2020
10/11/21