Loading...
HomeMy WebLinkAboutP101A - FIRST FLOOR PLUMBING PLAN - AREA A1/A3012/A3013/A3014/A301EW3EW3EW3EW2bEW3 EW3EW33/A303UPMDBP-1 RPBP-1A RPBP-1B ET DCVA-1 WATER METERS WHA-B WC-2 WC-2 L-2L-2 2" FD-1 2" FD-1 SK-2 WD-1 WSB-1 2" OSD-1 WH-1 WH-1 WH-1 FCO UNIT C2 2 UNIT C1 3 UNIT A1 4 UNIT A1 5 UNIT A1 6 UNIT B1 7 UNIT A1 8SOCIAL HUB 101 FOCUS BOOTH 104FOCUS BOOTH 105 FOCUS BOOTH 106FOCUS BOOTH 107 CONFERENCE ROOM 103 CONFERENCE ROOM 102 RESTROOM 108 RESTROOM 109 MAIL CENTER 111 DEMARC 116 WATER 117 UNIT A1 71 1 1 1 1 1 1 1 1 1313 2 3 2 3 2 3 13 13 13 13 13 13 2 3 2 3 2 3 13 13 2 3 23 23 2 3 2 3 4 5 4 5 4 5 12 13 4 5 12 5 4 12 5 4 12 12 12 5 4 12 5 4 12 FCO DWH-3 TET-3 4" W4" W 4" W W14 4" W4" W 4" W W14 4" W 4" W4" W CO 4" W WW 14 4" W 4" W WW4" W 4" W W 4" W 14 1/2" HW 1/2" CW 1/2" CW 1/2" CW 1/2" CW 3" FD-2 3" FD-2 1 1/2" V 1 1/2" V 1/2" HW 2" V 2" V 15 15 16 11 11 4" W4" W 4" W W W14 2" V 4" W W 14 4" W 14 4" W 4" WW 14 14 10 6 9 7 8 4" FD-2 12 3" W 12 3" W 3" W 4" W 3" W 4" WWARCHITECT CLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET APRIL 28TH, 2021 20005THE AVANTPHASE IIP101AFIRST FLOORPLUMBING PLAN -AREA ACARMEL,INSHEET KEYNOTES 1 3/4" COLD WATER FROM ABOVE IN WALL. 2 4" WASTE STACK IN WALL. 3 4" VENT STACK IN WALL. 4 3" WASTE STACK IN WALL. 5 2" VENT STACK IN WALL. 6 WET-PIPE FIRE SUPPRESSION SYSTEM. FIRE PROTECTION CONTRACTOR TO DESIGN, FURNISH AND INSTALL A COMPLETE FIRE SUPPRESSION SYSTEM FOR ENTIRE BUILDING PER NFPA 13. 7 6" INCOMING FIRE SERVICE WATER LINE. 8 6" INCOMING DOMESTIC WATER SERVICE LINE. 9 4" FIRE LINE DOWN TO POINT BELOW FLOOR TO FIRE DEPARTMENT CONNECTION (FDC). SEE SITE/CIVIL DRAWINGS FOR EXACT LOCATION. 10 4" COLD WATER UP IN CORNER INTO CHASE ABOVE. 11 3/4" COLD WATER FROM ABOVE IN WALL. 12 3" WASTE FROM ABOVE. 13 4" WASTE FROM ABOVE. 14 4" WASTE DOWN IN WALL TO POINT BELOW FLOOR SLAB. 15 1/2" COLD WATER AND 1/2" HOT WATER DROP IN WALL. 1-1/2"V RISE. 2"W DOWN. 16 1-1/2" COLD WATER DROP IN WALL. N 1/8" = 1'-0" FIRST FLOOR PLUMBING PLAN -AREA A1 GENERAL NOTES A REFER TO DRAWING P000 FOR PLUMBING AND FIRE PROTECTION SYMBOLS, LEGENDS, ABBREVIATIONS, ADDITIONAL GENERAL NOTES AND PLUMBING NOTES. B REFER TO P500 SERIES DRAWINGS FOR PLUMBING DETAILS. C REFER TO P600 SERIES DRAWINGS FOR PLUMBING SCHEDULES. D PROVIDE CEILING ACCESS PANELS AT SHUT-OFF VALVES, CONTROL VALVES, DRAIN VALVES, ETC. THAT ARE LOCATED ABOVE A NON-LAY-IN OR ACCESSIBLE CEILING. E INSTALL ALL PIPING AS HIGH AS POSSIBLE. F ALL PIPING, INSULATION, JACKETS, COVERINGS, SEALERS, MASTICS, AND ADHESIVES ARE TO BE PLENUM RATED WITHIN RETURN AIR PLENUMS, HAVING A FLAME-SPREAD INDEX OF 25 OR LESS, AND A SMOKE-DEVELOPED INDEX OF 50 OR LESS, AS REQUIRED BY CODE. # DESCRIPTION DATE 1 ASI-01 12/14/2020 10/11/21