3/4" CW
1 1/2" CW
1 1/4" CW
4" CW 4" CW 1 1/2" CW
1 1/4" CW
4" CW 3" CW 1 1/2" CW
1 1/4" CW
3" CW 1 1/2" CW 2 1/2" CW
1 1/4" CW
1 1/2" CW
2 1/2" CW
2" CW
1 1/2" CW
7
6
1 1/4" CW
1 1/4" CW
1 1/4" CW ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET
APRIL 28TH, 2021
20005THE AVANTPHASE IIP102BSECOND FLOORPLUMBING PLAN -AREA BCARMEL,INSHEET KEYNOTES
1 3/4" COLD WATER DROP IN WALL. 1" COLD WATER UP IN WALL ABOVE.
2 4" WASTE STACK IN WALL.
3 4" VENT STACK IN WALL.
4 3" WASTE STACK IN WALL.
5 2" VENT STACK IN WALL.
6 3/4" COLD WATER DOWN IN WALL TO POINT BELOW FLOOR SLAB.
7 1-1/2" COLD WATER DOWN IN WALL TO POINT BELOW FLOOR SLAB.
8 1" COLD WATER DROP IN WALL. 3/4" COLD WATER DOWN TO POINT BELOW
FLOOR SLAB. 1" COLD WATER UP IN WALL ABOVE.
N
1/8" = 1'-0"
SECOND FLOOR PLUMBING PLAN - AREA B 1
GENERAL NOTES
A REFER TO DRAWING P000 FOR PLUMBING AND FIRE PROTECTION SYMBOLS,
LEGENDS, ABBREVIATIONS, ADDITIONAL GENERAL NOTES AND PLUMBING
NOTES.
B REFER TO P500 SERIES DRAWINGS FOR PLUMBING DETAILS.
C REFER TO P600 SERIES DRAWINGS FOR PLUMBING SCHEDULES.
D PROVIDE CEILING ACCESS PANELS AT SHUT-OFF VALVES, CONTROL VALVES,
DRAIN VALVES, ETC. THAT ARE LOCATED ABOVE A NON-LAY-IN OR
ACCESSIBLE CEILING.
E INSTALL ALL PIPING AS HIGH AS POSSIBLE.
F ALL PIPING, INSULATION, JACKETS, COVERINGS, SEALERS, MASTICS, AND
ADHESIVES ARE TO BE PLENUM RATED WITHIN RETURN AIR PLENUMS,
HAVING A FLAME-SPREAD INDEX OF 25 OR LESS, AND A SMOKE-DEVELOPED
INDEX OF 50 OR LESS, AS REQUIRED BY CODE.
# DESCRIPTION DATE
10/11/21