HomeMy WebLinkAboutP104B - FOURTH FLOOR PLUMBING PLAN - AREA BEW3EW2bA2A1A1 A1 631154 B1 631154 B1 631154B1631154 B1 631154B1 DNA1aA1a 1 2 3 5 4 1 1 1 1 1 1 1 1 1 1 23 2 3 2 3 5 4 5 4 2 3 2 3 5 4 23 2 3 5 4 2 3 5 4 5 4 5 4 5 4 2 3 2 3 5 4 2 3 5 4 2 3 2 3 2 3 2 3 23 2 3 3/4" CW 6 UNIT A1 135 UNIT A1 136 UNIT B1 137 UNIT A1 138 UNIT B1 139 UNIT A1 140 UNIT B1 141 UNIT B1 166 UNIT B1 167 UNIT C2 168 UNIT A2 169 ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET APRIL 28TH, 2021 20005THE AVANTPHASE IIP104BFOURTH FLOORPLUMBING PLAN -AREA BCARMEL,INN 1/8" = 1'-0" FOURTH FLOOR PLUMBING PLAN - AREA B1 SHEET KEYNOTES 1 3/4" COLD WATER FROM BELOW FLOOR IN WALL. 2 4" WASTE STACK IN WALL. 3 4" VENT STACK IN WALL. 4" VENT THRU ROOF. 4 3" WASTE STACK IN WALL. 5 2" VENT STACK IN WALL. 4" VENT THRU ROOF. 6 3/4"CW UP TO ROOF HYDRANT (RH-1) ON ROOF. GENERAL NOTES A REFER TO DRAWING P000 FOR PLUMBING AND FIRE PROTECTION SYMBOLS, LEGENDS, ABBREVIATIONS, ADDITIONAL GENERAL NOTES AND PLUMBING NOTES. B REFER TO P500 SERIES DRAWINGS FOR PLUMBING DETAILS. C REFER TO P600 SERIES DRAWINGS FOR PLUMBING SCHEDULES. D PROVIDE CEILING ACCESS PANELS AT SHUT-OFF VALVES, CONTROL VALVES, DRAIN VALVES, ETC. THAT ARE LOCATED ABOVE A NON-LAY-IN OR ACCESSIBLE CEILING. E INSTALL ALL PIPING AS HIGH AS POSSIBLE. F ALL PIPING, INSULATION, JACKETS, COVERINGS, SEALERS, MASTICS, AND ADHESIVES ARE TO BE PLENUM RATED WITHIN RETURN AIR PLENUMS, HAVING A FLAME-SPREAD INDEX OF 25 OR LESS, AND A SMOKE-DEVELOPED INDEX OF 50 OR LESS, AS REQUIRED BY CODE. # DESCRIPTION DATE 10/11/21