Loading...
HomeMy WebLinkAboutP401 - ENLARGED PLUMBING PLANSA1a WC-1 L-1 L-1 BT-1 WB-1 WMDP-1 3" W 2" OSD-1 3" V SK-1 WD-1 TET-1 DWH-1 USB-1 10 9 13 12 1 5 3 3 2 7 15 8 11 14 6 2" V 5 WSB-1 3" W 3" W 2" W WC-1 L-1 L-1 BT-1 WB-1 WMDP-1 3" W 2" OSD-1 3" V SK-1 WD-1 TET-1 DWH-1 USB-1 10 9 13 12 1 5 3 32 7 15 8 11 14 6 2" V 5 WSB-1 3" W 3" W 2" W WC-1 L-1 L-1 BT-1 WB-1 WMDP-1 3" W 2" OSD-1 2" V SK-1 WD-1 10 9 13 12 5 3 37 15 8 14 6 TET-1 DWH-1 USB-1 1 2 11 4 WSB-1 2" V 4 3" W 5 WC-1 L-1 BT-1 3" W2" V 10 9 5 37 14 6 4 USB-1 1 2 WMDP-1 2" OSD-1 SK-1 AAV-1 13 12 15 DWH-1 118 TET-1 2" V 3" W WSB-1 3 3" W 2" W ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET APRIL 28TH, 2021 20005THE AVANTPHASE IIP401ENLARGED PLUMBINGPLANSCARMEL,INGENERAL NOTES A REFER TO DRAWING P000 FOR PLUMBING AND FIRE PROTECTION SYMBOLS, LEGENDS, ABBREVIATIONS, ADDITIONAL GENERAL NOTES AND PLUMBING NOTES. B REFER TO P500 SERIES DRAWINGS FOR PLUMBING DETAILS. C REFER TO P600 SERIES DRAWINGS FOR PLUMBING SCHEDULES. D PROVIDE CEILING ACCESS PANELS AT SHUT-OFF VALVES, CONTROL VALVES, DRAIN VALVES, ETC. THAT ARE LOCATED ABOVE A NON-LAY-IN OR ACCESSIBLE CEILING. E INSTALL ALL PIPING AS HIGH AS POSSIBLE. F ALL PIPING, INSULATION, JACKETS, COVERINGS, SEALERS, MASTICS, AND ADHESIVES ARE TO BE PLENUM RATED WITHIN RETURN AIR PLENUMS, HAVING A FLAME-SPREAD INDEX OF 25 OR LESS, AND A SMOKE-DEVELOPED INDEX OF 50 OR LESS, AS REQUIRED BY CODE. G ALL UNITS WITH ROOF EXPOSURE ARE TO HAVE DOMESTIC WATER PIPING ROUTED UNDERFLOOR (ABOVE CEILING OF UNIT BELOW). ALL UNDERGROUND DOMESTIC PIPING TO BE TYPE "K" COPPER. H ALL DOMESTIC WATER PIPING (COLD AND HOT) IN UNIT TO BE 1/2" SIZE UNLESS NOTED OR SHOWN OTHERWISE. I ALL WASTE PIPING IN UNIT TO BE 2" SIZE UNLESS NOTED OR SHOWN OTHERWISE. J ALL VENT PIPING IN UNIT TO BE 1 -1/2" SIZE UNLESS NOTED OR SHOWN OTHERWISE. 1/4" = 1'-0" ENLARGED UNIT A1 PLUMBING PLAN 1 1/4" = 1'-0" ENLARGED UNIT A1a PLUMBING PLAN2 1/4" = 1'-0" ENLARGED UNIT A1b PLUMBING PLAN3 1/4" = 1'-0" ENLARGED UNIT A2 PLUMBING PLAN4 SHEET KEYNOTES 1 3/4" INCOMING COLD WATER TO UNIT (USB-1). 2 3/4" CW RISE IN WALL. 3 1/2" CW DROP IN WALL. 4 1/2" CW & 1/2" HW DROP IN WALL. 1-1/2" VENT RISE. 2" WASTE DOWN. 5 1/2" CW & 1/2" HW DROP IN WALL. 6 2" W WITH P-TRAP UP TO TUB/SHOWER. 7 3" W UP TO WATER CLOSET. 8 2" W WITH P-TRAP UP TO (OSD-1). 9 4" VENT STACK. 10 4" WASTE STACK 11 3/4" CW TO WATER HEATER. 3/4" HW FROM WATER HEATER. 12 2" VENT STACK. 13 3" WASTE STACK. 14 1/2" CW AND 1/2" HW DROP IN WALL TO POINT BELOW FLOOR. 15 1/2" CW & 1/2" HW UP FROM BELOW FLOOR IN CASEWORK. 2" WASTE DOWN. 1-1/2" VENT UP IN CASEWORK AS HIGH AS POSSIBLE AND INSTALL AIR ADMITTANCE VALVE (AAV). WSB-1 # DESCRIPTION DATE 10/11/21