Loading...
HomeMy WebLinkAboutP403 - ENLARGED PLUMBING PLANSC1 C1 BALCONY 54 SQ FT C2 WC-1 L-1 BT-1 10 9 5 3 7 6 4 WC-1 SH-1 5 3 7 16 10 9 14 L-1 L-1 4 4 1 2 2" OSD-1 DWH-2 11 USB-1 TET-2 8 WMDP-1 SK-1 WD-1 15 13 12WB-1WSB-1 17 2" V 2" V 3/4" HW 3/4" CW WC-1 L-1 L-1 BT-1 10 9 5 3 7 6 44 WC-1 SH-1 5 3 7 16 10 9 14 L-1 L-1 4 4 1 22" OSD-1 DWH-2 11 USB-1 TET-2 8 WMDP-1 SK-1 WD-1 15 13 12WB-1 WSB-1 17 3" W 2" V2" V 3/4" HW 3/4" CW 2" V 3/4" CW 3/4" HW 3/4" CW 3/4" HW 5 3/4" CW 2" V 3" W 2" V 3" W 3/4" HW 3/4" CW 3/4" CW WC-1 L-1 BT-1 10 9 5 3 7 6 4 WC-1 SH-1 5 3 7 16 10 9 14 L-1 L-1 4 4 1 2 2" OSD-1 DWH-2 11 USB-1 TET-2 8 WMDP-1 SK-1 WD-1 15 13 12WB-1 3/4" CW 3/4" HW 3/4" CW 3/4" HW 2" V 2" V 3" W 3" W 3/4" HW 3/4" CW 2" V WSB-1 17 2" V 3" W ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET APRIL 28TH, 2021 20005THE AVANTPHASE IIP403ENLARGED PLUMBINGPLANSCARMEL,INGENERAL NOTES A REFER TO DRAWING P000 FOR PLUMBING AND FIRE PROTECTION SYMBOLS, LEGENDS, ABBREVIATIONS, ADDITIONAL GENERAL NOTES AND PLUMBING NOTES. B REFER TO P500 SERIES DRAWINGS FOR PLUMBING DETAILS. C REFER TO P600 SERIES DRAWINGS FOR PLUMBING SCHEDULES. D PROVIDE CEILING ACCESS PANELS AT SHUT-OFF VALVES, CONTROL VALVES, DRAIN VALVES, ETC. THAT ARE LOCATED ABOVE A NON-LAY-IN OR ACCESSIBLE CEILING. E INSTALL ALL PIPING AS HIGH AS POSSIBLE. F ALL PIPING, INSULATION, JACKETS, COVERINGS, SEALERS, MASTICS, AND ADHESIVES ARE TO BE PLENUM RATED WITHIN RETURN AIR PLENUMS, HAVING A FLAME-SPREAD INDEX OF 25 OR LESS, AND A SMOKE-DEVELOPED INDEX OF 50 OR LESS, AS REQUIRED BY CODE. G ALL UNITS WITH ROOF EXPOSURE ARE TO HAVE DOMESTIC WATER PIPING ROUTED UNDERFLOOR (ABOVE CEILING OF UNIT BELOW). ALL UNDERGROUND DOMESTIC PIPING TO BE TYPE "K" COPPER. H ALL DOMESTIC WATER PIPING (COLD AND HOT) IN UNIT TO BE 1/2" SIZE UNLESS NOTED OR SHOWN OTHERWISE. I ALL WASTE PIPING IN UNIT TO BE 2" SIZE UNLESS NOTED OR SHOWN OTHERWISE. J ALL VENT PIPING IN UNIT TO BE 1 -1/2" SIZE UNLESS NOTED OR SHOWN OTHERWISE. 1/4" = 1'-0" ENLARGED UNIT C1 PLUMBING PLAN1 1/4" = 1'-0" ENLARGED UNIT C1a PLUMBING PLAN2 1/4" = 1'-0" ENLARGED UNIT C2 PLUMBING PLAN3 SHEET KEYNOTES 1 3/4" INCOMING COLD WATER TO UNIT (USB-1). 2 3/4" CW RISE IN WALL. 3 1/2" CW DROP IN WALL. 4 1/2" CW & 1/2" HW DROP IN WALL. 1-1/2" VENT RISE. 2" WASTE DOWN. 5 1/2" CW & 1/2" HW DROP IN WALL. 6 2"W WITH P-TRAP UP TO TUB/SHOWER. 7 3"W UP TO WATER CLOSET. 8 2"W WITH P-TRAP UP TO (OSD-1). 9 4" VENT STACK. 10 4" WASTE STACK 11 3/4"CW TO WATER HEATER. 3/4"HW FROM WATER HEATER. 12 2" VENT STACK. 13 3" WASTE STACK. 14 1/2" CW AND 1/2" HW DROP IN WALL TO POINT BELOW FLOOR. 15 1/2" CW & 1/2" HW UP FROM BELOW FLOOR IN CASEWORK. 2" WASTE DOWN. 1-1/2" VENT UP IN CASEWORK AS HIGH AS POSSIBLE AND INSTALL AIR ADMITTANCE VALVE (AAV). 16 2"W WITH P-TRAP UP TO SHOWER. 17 1/2"CW FROM BELOW FLOOR IN WALL. # DESCRIPTION DATE 10/11/21