HomeMy WebLinkAboutP501 - PLUMBING DETAILSBALL VALVE REDUCED PRESSURE BACKFLOW PREVENTER, MAXIMUM MOUNTING HEIGHT OF 5'-0" ABOVE FLOOR. BALL VALVE TO SYSTEM FROM WATER SUPPLY SOURCE AIR GAP DRAIN FUNNEL PIPE DISCHARGE TO FLOOR DRAIN TYPE AND SIZE. REFER TO PLANS AND SPECIFICATIONS FOR BRASS CLEANOUT PLUG WITH COUNTERSUNK HEAD 1/8" BEND IF CLEANOUT OCCURS AT END OF LINE. 18"X18"X4" SQUARE CONCRETE PAD. TROWEL SMOOTH AND EDGE WASTE LINE 1/8" BEND 1 1/2" VENT 1/2"CW 1/2"HW SHUTOFF VALVE WITH THREADED HOSE CONNECTION. PROVIDE WITH WATER HAMMER ARRESTOR 2" WASTE P-TRAP WITH UNION CONNECTIONS FLOOR LINE CLOTHES WASHER RECESSED WALL BOX WITH FACE PLATE; EQUAL TO GUY GRAY SERIES RECESSED WALL BOXES. TRAP SHALL NOT BE INSTALLED BELOW FLOOR BUT SHALL BE ROUGHED IN NOT LESS THAN 6" AND NOT MORE THAN 18" ABOVE FLOOR. NO STANDPIPE RECEPTOR SHALL EXTEND MORE THAN 30" NOR LESS THEN 18" ABOVE ITS TRAP. TEES, PLUGS & HYDRANTS TEES, PLUGS & HYDRANTS ELBOWS 4. A BEARING CAPACITY OF 2000# PER FOOT WAS USED IN DETERMINING THE MINIMUM 1. THRUST BLOCK SHALL BE FC'=2500 PSI @ 28 DAYS (SEE SPECIFICATIONS SECTION 03300) BEARING AREA (SQUARE FEET) ELBOWS 5. THE CROSS SECTION OF THE THRUST BLOCKS SHALL BE SQUARE. "BEARING AREAS" IN THE ABOVE TABLES. 3. BOLTS, FITTING & JOINTS SHALL BE KEPT CLEAR OF CONCRETE. 2. ALL THRUST BLOCKS SHALL BE POURED AGAINST UNDISTURBED EARTH."A"3.518 21.0 20 4.0 26.0 2.0 6 8 16 12 10 2.5 2.5 3.0 3.0 4 INCHES PIPE DIA. 2.0 "A" FEET 2.9 4.8 17.1 10.0 7.1 1.5 SQUARE FEET BEARING AREA 18 3.0 30.0 20 3.0 36.8 4 INCHES 8 10 12 16 6 PIPE DIA. 2.0 3.0 3.0 2.5 2.0 6.8 4.1 10.1 14.1 24.2 FEET "A" 1.5 90° 2.1 8.316.3 4.2 19.9 10.1 5.1 3.7 13.0 7.6 5.5 2.2 1.9 2.8 3.9 6.7 1.1 45° 1.1 0.6 22-1/2° 0.9 1.4 0.6 3.3 2.0 11-1/4° 0.3 "A" SINK (SK-1) SHUT-OFF VALVE REDUCER GARBAGE DISPOSAL (WD-1) 5/8" DRAIN HOSE 1 1/2" VENT 2" SAN DISHWASHER 1/2" HW CW SUPPLY HW SUPPLY CODE APPROVED AIR ADMITTANCE VALVE (AAV) COUNTERTOP 4" MIN. INSTALL AS HIGH AS POSSIBLE UNDER THE COUNTERTOP SYSTEM RISER CAST IRON FLANGE AND SPIGOT PIECE. CAST IRON BELL AND SPIGOT PIPE. THRUST BLOCKING. RODS FIRE SERVICE MAIN RESTRAINT BUILDING SLAB PIPE DOUBLE SUPPORT NUT LOCKING NUT HANGER ROD HANGER ROD LOCKING NUT SUPPORT NUTCLEVIS HANGER 14 GAUGE ZINC COATED SHEET STEEL SADDLE AT LEAST 12" LONG PIPE INSULATION INSULATION PREFORMED PIPE SUPPORT INSERT, SAME THICKNESS AS INSULATION MANUFACTURED FOR THIS PURPOSE. RPBP-1A METER RPBP-1B METER REDUCED PRESSURE ZONE TYPE BACKFLOW PREVENTER 4"CW TO BUILDING SERVICE PROVIDE REMOTE WATER METER READ OUTS NEEDLE VALVE PRESSURE GAUGE FINISHED FLOOR SUPPORT PIPING AS REQUIRED TYPICAL DRAIN FUNNEL WITH AIR GAP, TERMINATE DRAIN LINE OVER NEAREST FLOOR DRAIN 4"CW INCOMING WATER SERVICE FLOOR SLEEVE COUPLING ADAPTOR (TYP) GATE VALVE (TYP)MAXIMUM MOUNTINGHEIGHT OF 5'-0"ABOVE FLOOR.1. ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH UTILITY COMPANY'S REQUIREMENTS. WATER METER FURNISHED BY LOCAL UTILITY, CONTRACTOR INSTALLED. NOTE: 4"CW 4"CW FINISH HEIGHT OF ROOF HYDRANT TO BE MIN OF 3'-0" A.F.R. ROOF MEMBRANE 3/4" COLD WATER PENETRATION BOOT & FLASHING TO MEMBRANE ROOFING BY ROOFING CONTRACTOR. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION PROVIDE STAINLESS STEEL CLAMPING BAND SURE SEAL WATER CUT-OFF MASTIC ROOF DECK - SEE ARCHITECTURAL DRAWINGS FOR CONSTRUCTION OPENING IN DECK BY PLUMBING CONTRACTOR HEAD CASTING DUAL CHECK VALVE 3/4" HOSE CONNECTION HANDLE WATER TIGHT SEAL UNDER DECK FLANGE MOUNTING BOLTS (4)MIN OF 10"OR CUSHION STRIP NEOPRENE ISOLATORTHREADED STEEL HANGER ROD SYSTEM PIPE (REFER TO DRAWINGS FOR TYPE OF STRUT PIPE CLAMP UNI-STRUT TRAPEZE SUPPORTINSULATION PIPE INSULATION MATERIAL (REFER TO SPECIFICATIONS) STEEL ROD COUPLING SYSTEM AND PIPE SIZE) BLOCKING ASME T&P RELIEF VALVE HEAT TRAPS BALL VALVE WITH RELIEF VALVE EQUAL TO WATTS #LFBRV HW HVAC FURNACE CW HW CWHWCWR WALL THERMOMETER WALL SEE FLOOR PLANS FOR SIZE OF COLD WATER PIPE MAINS CEILING 3"X2" OPEN SITE DRAIN (OSD) FINISH FLOOR DRAIN PAN FULL SIZE DRAIN VALVE FULL SIZE TO OSD DRAIN TUBE TO OSD NOTE: WHERE CONNECTING DISSIMILAR MATERIALS, FITTINGS ARE TO BE DIELECTRIC. DOMESTIC TANK TYPE ELEC. WATER HEATER (DWH-1) UNIT MECHANICAL CLOSET TO FIXTURES IN UNIT 3/4"CW 3/4"HW 3/4"CW 3/4"CW 3/4"HW 3/4"CW USB-1 TET-1 (DWH-2) TET-2 (SEE ENLARGED FLOOR PLANS) PENETRATION BOOT & FLASHING TO MEMBRANE ROOFING BY ROOFING CONTRACTOR BASED ON CARLISLE U-8-A. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION. PROVIDE STAINLESS STEEL CLAMPING BAND SURE SEAL WATER CUT-OFF MASTIC ROOK DECK - SEE ARCHITECTURAL DRAWINGS FOR CONSTRUCTION. OPENING IN DECK BY PLUMBING CONTRACTOR. SEE DRAWINGS FOR SIZE REDUCER AS REQUIRED PIPE SIZE PER DRAWINGS12"ARCHITECTCLIENT CONSULTANT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONSKBSO Consulting1344 S Rangeline Rd. Suite 202CARMEL, INDIANA 46032P: 317-344-8044PERMIT SET APRIL 28TH, 2021 20005THE AVANTPHASE IIP501PLUMBING DETAILS CARMEL,INNOT TO SCALE BACKFLOW PREVENTER DETAIL 1 NOT TO SCALE CLEANOUT DETAIL2 NOT TO SCALE CLOTHES WASHER BOX PIPING DETAIL3 NOT TO SCALE CONCRETE THRUST BLOCK DETAIL4 NOT TO SCALE DISHWASHER/DISPOSAL/SINK DEATIL5 NOT TO SCALE INCOMING FIRE SERVICE CONNECTION DETAIL6 NOT TO SCALE PIPE HANGER DETAIL7 NOT TO SCALE INCOMING DOMESTIC WATER SERVICE DETAIL9 NOT TO SCALE ROOF HYDRANT DETAIL10 NOT TO SCALE TRAPEZE DETAIL 11 NOT TO SCALE UNIT WATER HEATER DETAIL12 NOT TO SCALE VENT THRU ROOF DETAIL13 # DESCRIPTION DATE 10/11/21