HomeMy WebLinkAboutSD3-1-ROOF FRAMING DETAILS7'-0" MAX.SHEATHING EACH SIDE
RE: SPECS.
STAGGER VERTICAL JOINTS
ON EXTERIOR AND
INTERIOR FACES
EDGE NAILING
2X4 BLOCKING
@ 24" O.C.,
W/C520 CONT.
ACROSS TOP
GIRDER TRUSS SISTERED
NEXT TO PARAPET JACK TRUSSES AND
DESIGNED FOR 100 PLF D.L.
(OMIT WHERE LOAD BEARING WALL IS PRESENT)
3 PARAPET JACK TRUSS @ PARAPET RETURN
3/4" = 1'-0" (SEE TYPICAL DETAILS FOR INFORMATION NOT SHOWN)TOP OF PLATEJACK TRUSS
W/INTEGRAL PARAPETTOP OF PLATEGIRDER TRUSS
HANGER SIZED & PROVIDED BY TRUSS MFGR.
1 PARAPET TRUSS @ EXT. WALL
SCALE: 3/4" = 1'-0" (SEE TYPICAL DETAILS FOR INFORMATION NOT SHOWN)2 PARAPET JACK TRUSS @ EXT. WALL
SCALE: 3/4" = 1'-0" (SEE TYPICAL DETAILS FOR INFORMATION NOT SHOWN)
OVERSIZED 2X BLOCKING
GIRDER TRUSS
HANGER SIZED & PROVIDED BY TRUSS MFGR.,TYP.
LOAD BEARING WALL
WHERE SHOWN ON PLAN
ROOF TRUSS, INSTALL PER BCSI
ROOF TRUSS, INSTALL PER BCSI
ROOF TRUSS, INSTALL PER BCSI
SCALE: 3/4" = 1'-0"
TRUSS @ INTERIOR WALL 7
DRAFTSTOP
WHEN SHOWN
ON ARCHITECTURAL
PLANS
2X PARTY WALL
AIR SPACE
RE. ARCH
GIRDER TRUSS
HANGER SIZED & PROVIDED BY
TRUSS MANUFACTURER.
4 TRUSS TO GIRDER TRUSS
SCALE: 3/4" = 1'-0" (SEE TYPICAL DETAILS FOR INFORMATION NOT SHOWN)
FLUSH BEAM,
RE:PLAN FLUSH BEAM,
RE:PLAN 2X4 BLOCKING
@ 6'-0" O.C. EA. SIDE2X PARTY WALL
DRAFTSTOP
WHEN SHOWN
ON ARCHITECTURAL
PLANS
2X BLOCKING
@ 6'-0" O.C. EA. SIDE
(SEE TYPICAL DETAILS FOR INFORMATION NOT SHOWN)
SCALE: 3/4" = 1'-0"
TRUSS@PARTY WALL6 (SEE TYPICAL DETAILS FOR INFORMATION NOT SHOWN)
SCALE: 3/4" = 1'-0"
TRUSS@FLUSH BEAM5 (SEE TYPICAL DETAILS FOR INFORMATION NOT SHOWN)
PARALLEL CONDITION PERPENDICULAR CONDITION PERPENDICULAR-PARALLEL CONDITION
PERPENDICULAR-PERPENDICULAR CONDITION PERPENDICULAR-PARALLEL CONDITION
PARALLEL CONDITION PERPENDICULAR-PARALLEL CONDITION
ROOF DECKING
CONTINUOUS ACROSS
WITH NO PARALLEL JOINTS W/IN24"
DECK EDGE NAILING
ROOF TRUSS (ORIENTATION
MAY VERY, RE: ARCH)
0.131"X3" @ 4" O.C. - EACH SIDE
2X4 BLOCKING
(2) 2X6 STRONG BACK
DIAGONAL BRACES@48" O.C.
FIRE WALL
RE: ARCH
A34 W/ SCREWS
(TYP.)
ROOF TRUSS (ORIENTATION
MAY VERY, RE: ARCH)
8 TRUSS @ FIREWALL
SCALE: 3/4" = 1'-0"
(4)0.131"X3" END NAILS, TYP.TOP OF PLATE TOP OF PLATE (SEE TYPICAL DETAILS FOR INFORMATION NOT SHOWN)
STAGGERED TRUSS BEYOND
STAGGERED TRUSS BEYOND
DRAG TRUSS W/ CLIPPING
@ SHEARWALL CONDITIONS,
RE: STD. DTL.
AIR SPACE
RE: ARCH
DRAG TRUSS W/ CLIPPING
@ SHEARWALL CONDITIONS,
RE: STD. DTL.
HORIZONTAL H2.5A (TYP.)
(4)0.131"X3", TYP.
CONT. 2X6 W/0.131"X3"
@ 4" O.C. - EACH SIDE
(4)0.131"X3" END NAILS, TYP.
DRAFTSTOP
WHEN SHOWN
ON ARCHITECTURAL
PLANS
DRAG TRUSS W/ CLIPPING
@ SHEARWALL CONDITIONS,
RE: STD. DTL.
AIR SPACE
RE. ARCH
PROVIDE SEAT
IN TRUSS
A TYPICAL FLAT ROOF FRAMING DETAIL WITH PARAPET
NOT TO SCALETOP OF PLATEVARIESPARAPET HEIGHT - RE: ARCH. 5'-2" MAX U.N.O.DESIGNED BY TRUSS MANUF.RE: TRUSS MANUF. - 2'-0" MIN. ROOF TRUSS
INSTALL PER BCSI(2) 2X BEARING TOP PLATES
HANGER SIZED & PROVIDED
BY TRUSS MFGR.
JACK TRUSS
WALL PERPENDICULAR TO TRUSSES WALL PARALLEL TO TRUSSES
PARAPET AND OVERHANG BUILT
INTEGRAL WITH TRUSS PER MANUF.
(WIND LOADS BY TRUSS MANUF.)
2X BLOCKING WITH
0.131" x 3" @ 4"O.C.
CONTINUE
SHEATHING OVER
END OF TRUSS TO TOP
OF PARAPET.
EDGE NAILING
2X STUD WALL
HEADER OR DROP BEAM INSTEAD
WHERE SHOWN ON PLAN
SLOPE PER ARCH
(2) 2X BEARING
TOP PLATES
2X STUD WALL
ROOF TRUSS
INSTALL PER BCSI
HEADER OR DROP BEAM INSTEAD
WHERE SHOWN ON PLAN
2X4 BLOCKING
@ 6'-0" O.C. EA. SIDETOP OF PLATE2X RIM JOIST 2X12 JOISTS@16" O.C. RIPPED AS
REQ'D TO CREATE SLOPE. SEE ARCH.
2X8 NAILER, ATTACHED PER SILL
PLATE SCHEDULE FOR A W1 WALL.
HOIST BEAM
RE:PLANS+STD DTLS
8" CMU WALL
RE: SPECS.VERIFY OVERUN & HOIST BEAM HEIGHT W/ MANUFELEVATOR
OPENING
EDGE NAILING
CONT. 2X6 IN RIBBON SPACE
W/1/2" X6" TITEN HD@12"O.C.
W/3"X3"X0.25"WASHERS
IN BOTTOM 2" VERT. LONG
SLOTTED HOLES IN LEDGER,
DO NOT OVER TIGHTEN
CMU WALL
RE: SPECS.
TWO COURSE
HIGH BOND BEAM
FOR LEDGER
RE: SPECS.
EDGE NAILING 9 ROOF FRAMING @ELEVATOR
3/4" = 1'-0" (SEE TYPICAL DETAILS FOR INFORMATION NOT SHOWN)TOP OF PLATETOP OF PLATE10 PARALLEL TRUSSES@CMU
3/4" = 1'-0" (SEE TYPICAL DETAILS FOR INFORMATION NOT SHOWN)
CONT. 2X6 W/1/2" X6"TITEN HD
@12"O.C. W/3"X3"X0.25"WASHERS
IN BOTTOM 2"VERT. LONG
SLOTTED HOLES IN LEDGER,
DO NOT OVER TIGHTEN 912 " MIN.A34@48"O.C.
RE: ARCH
ROOF TRUSS, INSTALL PER BCSI
ROOF TRUSS, INSTALL PER BCSI
BOND BEAM
RE: SPECS.
BOND BEAM
RE: SPECS.
ROOF JOIST CLIPPING
PER STANDARD NOTES
TOP OF PLATE11 PSL BEAM AT HIGH ROOF
3/4" = 1'-0" (SEE TYPICAL DETAILS FOR INFORMATION NOT SHOWN)
ROOF GIRDER TRUSS
RE: PLAN
BALLOON FRAME EXT. WALL TO
UNDERSIDE OF BEAM
FLATWISE 616 PSL BEAM
FASTEN TOP PLATES TO
PSL BEAM W/ SD SCREWS
@ 4" O.C.
CONT. HORIZ.
SHEAR BLOCK
BY TRUSS MANUF.
DESIGNED
FOR: 200PLF WL
CRICKET - RE: ARCH
BOUNDARY NAILING
BLOCKING
SIMPSON FRAMING
ANCHOR @ ALL
BEARING LOCATIONS
RE: STD. NOTES
CONT 2X
RIBBON, TYP
ROOF DECKING
GIRDER
TRUSS
OVERHANG 2'-0" MAX
RE: ARCH VARIESPARAPET HEIGHT - RE: ARCH. 5'-2" MAX U.N.O.DESIGNED BY TRUSS MANUF.RE: TRUSS MANUF. - 2'-0" MIN. PARAPET AND OVERHANG BUILT
INTEGRAL WITH TRUSS PER MANUF.
(WIND LOADS BY TRUSS MANUF.)
2X BLOCKING WITH
0.131" x 3" @ 4"O.C.
CONTINUE
SHEATHING OVER
END OF TRUSS TO TOP
OF PARAPET.
SLOPE PER ARCH
CONT. HORIZ.
SHEAR BLOCK
BY TRUSS MANUF.
DESIGNED
FOR: 200PLF WL
CRICKET - RE: ARCH
BOUNDARY NAILING
BLOCKING
SIMPSON FRAMING
ANCHOR @ ALL
BEARING LOCATIONS
RE: STD. NOTES
ROOF DECKING
OVERHANG 2'-0" MAX
RE: ARCH
ROOF DECKING
CONTINUOUS ACROSS
WITH NO PARALLEL
JOINTS WITHIN 24"
DECK EDGE
NAILING , TYP
ROOF TRUSS (ORIENTATION
MAY VERY, RE: ARCH)
0.131"X3" @ 4" O.C. - EACH SIDE
2X4 BLOCKING
RE: ARCH
A34 W/ SD SCREWS
HORIZONTAL H2.5A (TYP.)
CONT. 2X W/ 0.131"X3" @ 4" O.C. - EACH SIDE
(OMIT AT 2X6 WALLS)
(2)2X6 STRONG-BACK DIAGONAL BRACES @ 48" O.C.,
JOINED WITH 0.131"X3" @ 6" O.C. W/ SPLICES @ 6' MIN.
WHEN >12' LONG, CROSS-BRACE TO TRUSS CHORDS
OR WEB BRACING IN MIDDLE THIRD
(4) 0.131"X3"
END/TOE NAILS @ ENDS OF
BLOCKING, TYP
(6)0.131"X3", TYP
2X BLOCKING
AT BRACE
CONNECTIONS
12 ROOF FRAMING AT STAIRWELL FIRE-BARRIER
3/4" = 1'-0"(SEE TYPICAL DETAILS FOR INFORMATION NOT SHOWN)
FIRE-BARRIER PER ARCH.
RE: PLAN FOR ADDITIONAL TRUSS
LOADS FOR ROOF TRUSSES OVER
STAIRWELLS
2X RIM BOARD
CONT 2X
RIBBON, TYP2X RIM BOARD
WIDTH PER TRUSS MANUF.
2'-0" MIN.
WIDTH PER TRUSS MANUF.
2'-0" MIN.
ROOF
FRAMING
DETAILS
3/4" = 1'-0"
SD3-1
SHEET NUMBER
AVANT PHASE II
18290 OLD
MERIDIAN ST
CARMEL, INDIANA
ISSUE DATE
ISSUE TITLE
SHEET TITLE
DRAWING SCALE
PROJECT NUMBER
PROJECT NAME & LOCATION
609.002.020
CAD / ENG
The words around this title block reflect the values and definition of Integrity Structural Corp. and do not include any notes pertaining to the drawings for this project. For God so loved the world that he gave his one and only Son, that whoever believes in him shall not perish but have eternal life. For God did not send his Son into the world to condemn the world, but to save the world through him. Whoever believes in him is not condemned, but whoever does not believe stands condemned already becauscree en él no es condenado, pero el que no cree ya está condenado por no haber creído en el nombre del Hijo unigénito de Dios. Ésta es la causa de la condenación: que la luz vino al mundo, pero la humanidad prefirió las tinieblas a la luz, porque sus hechos eran perversos. Pues todo el que hace lo malo aborrece la luz, y no se acerca a ella por temor a que sus obras queden al descubierto. En cambio, el que practica la verdad se acerca a la luz, para que se vea claramente que ha hecho sus obras en obedienin the name of God's one and only Son. This is the verdict: Light has come into the world, but men loved darkness instead of light because their deeds were evil. Everyone who does evil hates the light, and will not come into the light for fear that his deeds will be exposed. But whoever lives by the truth comes into the light, so that it may be seen plainly that what he has done has been done through God. (John 3:16-21, NIV). Therefore Jesus said again, "I tell you the truth, I am the gate for the sheep. All who ever came before me were thieves and robbers, but the sheep did not listen to them. I am the gate; whoever enters through me will be saved. He will come in and go out, and find pasture. The thief comes only to steal and kill and destroy; I have come that they may have life, and have it to the full. (John 10: 7-10, NIV) Jesus answered, "I am the way and the truth and the life. No one comes to the Father except through me." (John 14:6, NIV) These bible verses reflect Integrity Structural Co
CONSTRUCTION@
INTEGRITYSTRUCTURAL.COM
12777 JONES RD., STE 388
HOUSTON, TX 77070
281 894 7099
09/08/2020
DD SET
AD / RA
10/16/2020
PROGRESS SET
AD / RA
04/28/2021
PERMIT SET
AD / RA
10/11/21