Loading...
HomeMy WebLinkAboutState CDRELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 1/3 CONSTRUCTION DESIGN RELEASE State Form 41191 (R9/5-98) Report Printed on:August 30, 2021 Project number Release date 419972 02/04/21 Construction type Occupancy classification Scope of release SPK, V-A R-2, A-3, U, S-2 Type of release Project name Street address City County ARCH ELEC FA MECH PLUM STR Standard Avant Apartment Phase 2 12950 Old Meridian St CARMEL HAMILTON To: Owner / Architect / Engineer Studio M Architecture & Planning Alex Marsh AR12000062 6311 Westfield Blvd Suite 100 Indianapolis IN 46220 Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000. The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and void, if the work authorized is not commenced within one (1) year from the above date. CONDITIONS: ACDS 4G05 4G05A 4G0603AE This project consists of the second phase of the Avant Apartments development. Project will be a 4- story apartment complex with 94 units, an exercise facility, a clubhouse, coworking space, 20 private garages. This project has been reviewed under the 2014 Indiana Building Code, 2014 Indiana Fire Code, 2009 Indiana Electrical Code, 2012 Indiana Plumbing Code, 2014 Indiana Mechanical Code, 2014 Indiana Fuel Gas Code, 2010 Indiana Accessibility Chapter 11 (ICC A117.1 2009), and the 2010 Indiana Energy Conservation Code (ASHRAE 90.1 2007) All conditions set forth by the Indiana Fire Prevention and Building Safety Commission on variance submissions shall be considered part of the release documents and do not apply to future additions or alterations of this structure in accordance with 675 IAC l2-5. The Fire Prevention and Building Safety Commission has granted one or more variances which apply to this project. 20-12-69: Allows a posted occupant load of 49 for the clubhouse Allows the total area of U occupancy to be greater than 3,000sf Allows the non-rated door & sidelight between the corridor and the fitness room and clubhouse Allows the use of a double top plate of non-rated ceilings at 1-hr ceiling Allows the elimination of hoistway venting Allows the elimination of 2-way communication at elevator landings Allows the return air intake to be 5 ft from oven/rance instead of 10 ft Detailed plans and specifications of the fire suppression system shall be filed with the required application and appropriate fees in accordance with 675 IAC 12-6-3(a), 675 IAC 12-6-7(g)(17), and 675 IAC 13-1-8. (N.F.P.A. 13) Indiana Department of Homeland Security DIVISION OF FIRE & BUILDING SAFETY PLAN REVIEW DIVISION 402 W. Washington St., Room E245 Indianapolis, IN 46204 Fax & e-mail: SUPPORT HOOSIER SAFETY Available At Your Local Licence Branch In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a copy of the design release. 0000000000, amarsh@studiomarchitecture.net ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 2/3 14B4205 14B1008110 14B0907 14W09077 14M05041 14M05044 14M03045 14M0920 14B29021DF A2 AREL Group I-1, R-1 and R-2 occupancies shall be provided with fire alarm systems and smoke alarms in accordance with Section 420.5, IBC (675 IAC 13-2.6). Doors serving a Group H occupancy, or an occupant load of 50 or more in a Group A or E occupancy, shall not be provided with a latch or lock unless it is panic hardware or fire exit hardware in accordance with Section 1008.1.10, IBC (675 IAC 13-2.6). The fire alarm system shall be designed as specified in Section 907, IFC, and N.F.P.A. 72, in accordance with Section 907, IBC (675 IAC 13-2.6). Upon completion of the installation of the fire alarm system, a satisfactory test of the entire system shall be made. All functions of the system or alteration shall be tested in accordance with Section 907.7, IFC (675 IAC 22-2.5). Dryer exhaust systems shall be independent of all other systems and shall convey the moisture and any products of combustion to the outside of the building, in accordance with Section 504.1, IMC (675 IAC 18-1.6). Clothes dryer exhaust ducts shall terminate on the outside of the building, and shall be equipped with a backdraft damper; ducts shall not be connected or installed with sheet metal screws or other fasteners that will obstruct exhaust flow; in accordance with Section 504.4, IMC (675 IAC 18-1.6). Appliance height above finished floor shall be in accordance with Section 304.6 and 920 IMC (675 IAC 18-1.6) (Suspended Furnaces/Heaters) Suspended-type unit heaters shall be installed and supported in accordance with Section 920, IMC (675 IAC 18-1.6). The minimum number of required drinking fountains shall comply with Section 2902, Table 2902.1 and Chapter 11, IBC (675 IAC 13-2.6). NOTE: Club room or Coworking room. NOTE: Where bottled water or bottled water coolers are provided in other occupancies free of charge, drinking fountains shall not be required. Footnote H Table 2902.1, IBC. An elevator installation permit shall be obtained from the Elevator Safety Division in accordance with IESC (675 IAC 21-1-1). Please visit: http://www.in.gov/dhs/2374.htm Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from required compliance with all applicable rules of the commission, even if noncompliant conditions appear in the plans and specifications that have been filed with the division. The owner is responsible for correcting any and all areas of noncompliance even if they are discovered subsequent to the issuing of this design release. This order is effective upon service. If you would like to request informal review of this order, please complete the informal review form located at https://www.in.gov/dhs/4149.htm. Following receipt of this form, the Department may modify or reverse the order, however, a request for an informal review does not extend the deadline for filing a petition for review with the Fire Prevention and Building Safety Commission (Commission). Additionally, if you have any questions regarding this order, you may contact that Department at (317) 232-2222. If you desire a formal administrative review of this order by the Commission, you must comply with the requirements of Indiana Code § 4-21.5-3-7 and file a written petition for review within 15 days of the date this order was served, however, this period is extended to 18 days if service is made by mail. Your petition for review must state facts demonstrating that you are: (1) a person to whom the order is specifically directed; (2) aggrieved or adversely affected by the order; or (3) entitled to review under any law. You may submit your petition by the following methods: U.S. MAIL OR PERSONAL SERVICE ONLINE Fire Prevention and Building Safety Commission By completing the form at c/o Legal Counsel https://www.in.gov/dhs/4148.htm 302 W. Washington Street, Rm. E208 Indianapolis, IN 46204 For additional information about the administrative review process and applicable templates that may be used for filings, visit the following link https://www.in.gov/dhs/appeals.htm. ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 3/3 Code review official Address (name,title of local official,street,city,state and ZIP code DESHAWN JORMAN JIM BLANCHARD ONE CIVIC SQUARE CARMEL,IN 46032 DEPT OF COMMUNITY SERVICE Fax & e-mail: 3175712499, jblanchard@carmel.in.gov Indiana State Building Commissioner DJorman@dhs.IN.gov