HomeMy WebLinkAboutA002_GENERALNOTESA002 1. THESE GENERAL NOTES APPLY TO THE ENTIRE SET OF DRAWINGS AND ARE NOT SPECIFIC TO ANY DISCIPLINE 2. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF ALL SUBCONTRACTORS, TRADES AND SUPPLIERS WITH THE REQUIREMENTS OF THE CONTRACT BEFORE COMMENCING CONSTRUCTION, AND ASSURE THAT ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THE REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS, WHICH MIGHT AFFECT THE WORK OF THAT PARTY. 3. 0'-0" CORRESPONDS TO 862.35' ON CIVIL DRAWINGS. 4. THE WORK DESCRIBED BY THE DRAWINGS OF ANY OF THE DISCIPLINES MAY BE AFFECTED BY THE WORK DESCRIBED ON DRAWINGS OF ANOTHER DISCIPLINE AND MAY REQUIRE REFERENCE TO THE DRAWINGS OF ANOTHER DISCIPLINE. PARTIAL SETS OF DRAWINGS ARE INCOMPLETE AND SHOULD NOT BE DISTRIBUTED OR UTILIZED BY THE GENERAL CONTRACTOR. 5. THE GENERAL CONTRACTOR SHALL ENDEAVOR TO IDENTIFY AND NOTIFY THE ARCHITECT/ENGINEER OF CONFLICTS BETWEEN THE WORK OF DIFFERENT PARTIES AT THE EARLIEST POSSIBLE DATE SO AS TO ALLOW REASONABLE AND ADEQUATE TIME FOR THE CONFLICT TO BE RESOLVED WITHOUT DELAYING WORK. ALL DEVIATIONS FROM THAT WHICH IS REQUIRED BY THE CONTRACT DOCUMENTS MUST BE APPROVED IN ADVANCE BY THE ARCHITECT/ENGINEER AND OWNER. 6. THE GENERAL NOTES, SYMBOLS AND DEFINITIONS APPLICABLE ONLY TO EACH DISCIPLINE CAN BE FOUND AT THE FRONT OF EACH DISCIPLINE'S PORTION OF THE SET OF DRAWINGS AND IT IS LISTED AS PART OF THE OVERALL PROJECT INDEX OF DRAWINGS. 7. BASIC FIRE PROTECTION AND EXITING CONCEPTS ARE ILLUSTRATED BY THE CODE PLANS. 8. THE DRAWINGS MAY REFERENCE TO AND/OR ILLUSTRATE ITEMS WHICH ARE NOT PART OF THE WORK OF THE CONTRACT. THESE 'NOT IN CONTRACT' ITEMS AS INDICATED ARE REFERENCED AND/OR ILLUSTRATED FOR THE CONTRACTOR'S REFERENCE, INFORMATION AND COORDINATION ONLY. 9. THE GENERAL CONTRACTOR IS RESPONSIBLE TO COMPLY WITH ALL APPLICABLE LAWS, CODES, REGULATIONS AND ORDINANCES OF THE PLACE (CITY, COUNTY, DISTRICT, AND STATE) WHERE THE PROJECT IS LOCATED. ALTHOUGH SUCH REQUIREMENTS MAY NOT BE REFLECTED BY THESE DRAWINGS AND SPECIFICATIONS. 10. THE GENERAL CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND SIMILAR RELEASES REQUIRED FOR THE CONSTRUCTION AND OCCUPANCY OF THE PROJECT. THE GENERAL CONTRACTOR SHALL FURNISH COPIES OF ALL SUCH ITEMS TO THE OWNER AND ARCHITECT WITHIN 10 DAYS OF RECEIPT OF SUCH ITEMS. IF PERMITS ARE ISSUED SUBJECT TO CERTAIN CONDITIONS OR REVISIONS TO THE WORK OR IF PERMITS ARE DELAYED FOR ANY REASON, THE GENERAL CONTRACTOR SHALL NOTIFY THE OWNER AND ARCHITECT PROMPTLY. 11. THE GENERAL CONTRACTOR SHALL TAKE PRECAUTIONS TO MAINTAIN AND PROTECT NEW WORK AS WELL AS EXISTING SYSTEMS AND ELEMENTS WHICH ARE TO REMAIN. ANY DAMAGE TO SUCH SYSTEMS AND ELEMENTS SHALL BE IMMEDIATELY REPAIRED IN A MANNER ACCEPTABLE TO THE ARCHITECT / ENGINEER. IF SATISFACTORY REPAIRS CANNOT BE MADE, THE GENERAL CONTRACTOR SHALL REPLACE SYSTEMS AND ELEMENTS WITH 'LIKE NEW' QUALITY ACCEPTABLE TO THE ARCHITECT / ENGINEER. ALL REPAIRS AND REPLACEMENT COST SHALL BE THE FINANCIAL RESPONSIBILITY OF THE GENERAL CONTRACTOR. 12. ALL WORK ON THE DRAWINGS AND IN THE SPECIFICATIONS SHALL BE BASE BID UNLESS SPECIFICALLY NOTED TO BE BY ALTERNATE BID. 13. DO NOT SCALE DRAWINGS. REFER DIMENSION QUESTIONS TO ARCHITECT FOR INTERPRETATION. PROJECT GENERAL NOTES 1. THESE GENERAL NOTES APPLY TO ALL ARCHITECTURAL DRAWINGS. 2. REFER TO THE 'PROJECT GENERAL NOTES' FOR ALL GENERAL NOTES APPLICABLE TO ALL DRAWINGS OF ALL DISCIPLINES. 3. FOR GENERAL NOTES AND SYMBOLS APPLICABLE ONLY TO THE DRAWINGS OTHER THAN ARCHITECTURE, REFER TO THE SPECIFIC DRAWINGS OF THAT DISCIPLINE. 4. PARTIAL SETS OF DRAWINGS ARE INCOMPLETE AND SHALL NOT BE DISTRIBUTED NOR UTILIZED BY THE CONTRACTOR. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF ALL SUBCONTRACTORS, TRADES, AND SUPPLIERS WITH THE REQUIREMENTS OF THE CONTRACT BEFORE COMMENCING CONSTRUCTION AND TO ASSURE THAT ALL PARTIES ARE AWARE OF ALL REQUIREMENTS REGARDLESS OF WHERE THE REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS, WHICH MIGHT AFFECT THE WORK OF THAT PARTY. 5. THESE NOTES ARE ONLY APPLICABLE TO THIS PERMIT SET AND MAY NOT BE APPLICABLE TO FUTURE PACKAGES. 6. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK OF ALL SUBCONTRACTORS, TRADES AND SUPPLIERS. THE GENERAL CONTRACTOR SHALL ENDEAVOR TO IDENTIFY AND NOTIFY TO THE CONTRACTING OFFICER OF ANY CONFLICTS BETWEEN THE WORK OF DIFFERENT PARTIES AT THE EARLIEST POSSIBLE DATE SO AS TO ALLOW REASONABLE AND ADEQUATE TIME FOR THE CONFLICT TO BE RESOLVED WITHOUT DELAYING THE WORK. ALL DEVIATIONS FROM THAT WHICH IS REQUIRED BY THE CONTRACT DOCUMENTS MUST BE APPROVED IN ADVANCE BY THE CONTRACTING OFFICER. 7. THE ARCHITECTURAL DRAWINGS ESTABLISH AND COORDINATE THE FINISH APPEARANCE AND EXACT LOCATION OF ALL EXPOSED ELEMENTS OF THE WORK, INCLUDING THAT WORK WHICH IS ILLUSTRATED PRIMARILY ON DWGS. OF OTHER DISCIPLINES. LOCATIONS SHOWN ON OTHER DWGS. ARE SCHEMATIC, U.N.O. ON THE ARCHITECTURAL DWGS. THE ARCHITECTURAL DWGS. TAKE PRECEDENCE FOR THE FINISHED APPEARANCE AND EXACT LOCATIONS OF ALL PARTS OF THE WORK. EXCEPTION: DIMENSIONED LOCATIONS SHOWN ON DRAWINGS OF OTHER DISCIPLINES SHALL GOVERN ONLY WHERE: A. SPECIFICALLY AND INDIVIDUALLY INDICATED BY SYMBOL, KEYED NOTE, OR NOTATION ON THE ARCHITECTURAL DWGS. B. OCCURRING WITHIN A ROOM OR OTHER IDENTIFIED SPACE FOR WHICH ARCH. SHEET OR SCHEDULE NOTES INDICATE THAT DIMENSIONS PROVIDED ELSEWHERE SHALL GOVERN. 8. REFER TO THE STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR THE DETAILED DESIGN OF THE STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS OF WHICH PORTIONS ALSO MAY BE SHOWN ON THE ARCHITECTURAL DRAWINGS. 9. THE TERM 'REFERENCE' ELEVATION OR DIMENSIONS REFERS TO A NOMINAL WORK POINT. THE ACTUAL ELEVATION MAY VARY FROM THE REFERENCE POINT. REFER TO THE APPLICABLE DETAIL TO DETERMINE THE RELATIONSHIP BETWEEN THE ACTUAL ELEVATION OR DIMENSION AND THE STATED REFERENCE POINT. 10. 'FINISH FLOOR' ELEVATIONS ARE MEASURED AT THE TOP OF THE CONCRETE FLOOR SLAB, UNLESS NOTED OTHERWISE. 11. WHERE THE CONCRETE FLOOR SLAB IS DEPRESSED TO ACCOMMODATE MORTAR BEDS, SETTING BEDS, RAISED ACCESS FLOORS, AND OTHER SIMILAR FLOOR ASSEMBLIES, FINISHED FLOOR ELEVATIONS ARE MEASURED AS IF CONCRETE DEPRESSION DID NOT OCCUR. 12. CEILING HEIGHT DIMENSIONS ARE MEASURED TO FINISHED SURFACES, UNLESS NOTED OTHERWISE. 13. THE TERM 'REFERENCE ROOF ELEVATION' REFERS, UNLESS NOTED OTHERWISE, TO THE ELEVATION OF THE TOP OF THE STRUCTURAL ROOF ASSEMBLY AT THE PERIMETER OF THE AREA INDICATED. 14. WHERE THE STRUCTURAL ROOF ASSEMBLY IS SLOPED TO DRAIN, THE ACTUAL TOP OF THE ASSEMBLY ELEVATION WILL VARY FROM THE STATED 'REFERENCE ROOF ELEVATION'. SEE THE ARCH. ROOF PLANS AND THE STRUCTURAL DWGS. TO DETERMINE WHERE THE STRUCTURE IS SLOPED TO DRAIN. 15. INSULATION AND ROOFING MATERIALS RAISE THE ACTUAL FINISHED SURFACE OF THE ROOF ABOVE THE STATED ' REFERENCE ROOF ELEVATION'. THICKNESS OF INSULATION AND ROOFING MATERIALS VARIES WITH THE TYPE OF ROOF SYSTEMS INDICATED. SEE THE ARCHITECTURAL ROOF PLANS FOR SPECIFIC INFORMATION. 16. DIMENSIONS TO NEW CONSTRUCTION ARE TO FACE OF FRAMING, FACE OF CMU OR FACE OF STRUCTURAL CONCRETE WALL, U.N.O. 17. PROVIDE FINISH END PANELS, FILLERS, SUPPORTS, ETC., REQUIRED FOR A COMPLETE CABINETRY INSTALLATION. 18. VERIFY MOUNTING HEIGHTS OF ACCESSORIES, EQUIPMENT, DOOR HARDWARE, CASEWORK, ETC., AND PROVIDE SOLID BLOCKING OR METAL STRAPS BETWEEN FRAMING MEMBERS TO SUPPORT WEIGHT AND USE OF ITEMS TO BE SUPPORTED. WHERE MOUNTING HEIGHTS ARE NOT INDICATED, MOUNT ITEMS AT RECOGNIZED INDUSTRY STANDARD MOUNTING HEIGHTS. COORDINATE LOCATIONS WITH MANUFACTURER OR SUPPLIER. REFER ANY MOUNTING HEIGHT QUESTIONS TO ARCHITECT FOR INTERPRETATION. 19. PROVIDE CONTINUOUS SEALANT BETWEEN DISSIMILAR MATERIALS SUCH AS MASONRY AND CONCRETE, GYPSUM BOARD AND MASONRY, COUNTERTOPS AND WALLS, ETC. - COLOR TO BE APPROVED BY ARCHITECT / OWNER PRIOR TO INSTALLATION 20. LOCATE INSIDE (DOOR SIDE) FACE OF DOOR FRAME JAMBS 6 INCHES FROM THE FINISH FACE OF ADJACENT WALLS IN STEEL STUD ASSEMBLIES, U.N.O. - LOCATE R.O. OF DOOR FRAMES 4" FROM ADJACENT WALLS IN WOOD STUD ASSEMBLIES EXCEPT AT PRIMARY UNIT ENTRY DOORS WHICH SHOULD BE 6", U.N.O. 21. COORDINATE EQUIPMENT WORK WITH MANUFACTURERS AND SUPPLIERS PROPER ROUGH-IN CLEARANCES FOR INSTALLATION, USE, AND MAINTENANCE. 22. PROVIDE CONTROL JOINTS (C.J.) IN GYPSUM BOARD WALL CONSTRUCTION AS INDICATED. WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 30'-0". VERIFY FINAL CONTROL JOINT LOCATIONS WHETHER OR NOT INDICATED ON THE DRAWINGS WITH ARCHITECT PRIOR TO STARTING WORK. 23. STUD SPACING SHALL BE 16 INCHES, U.N.O. - REFER TO STRUCTURAL DRAWINGS. 24. DO NOT BEGIN ANY WORK THAT MAY REQUIRE COORDINATION SUCH AS CEILING INSTALLATION PRIOR TO FINAL SUBMITTAL OF MECHANICAL AND ELECTRICAL COORDINATION DRAWINGS TO ARCHITECT NOR PRIOR TO RESOLUTION AND APPROVAL OF ALL COORDINATION ISSUES. 25. WHEN WALL TAGS ARE INDICATED AT ONE FACE OF FURRED COLUMN, IT SHOULD BE CONSIDERED TO OCCUR ON ALL FACES OF THE COLUMN, U.N.O. 26. WALL TYPES ARE ASSUMED TO BE CONTINUOUS WITHIN THE SAME PLANE OR SURFACE UNTIL ANOTHER WALL TAG IS SHOWN. 27. PROVIDE CONTROL JOINTS (C.J.) IN MASONRY WALL CONSTRUCTION AS INDICATED. WHERE NOT SHOWN, PROVIDE MAXIMUM SPACING BETWEEN JOINTS OF 40'-0" AND MAXIMUM DISTANCE BETWEEN OUTSIDE CORNERS AND JOINTS OF 10'-0". PROVIDE JOINTS BETWEEN ALL INTERIOR LOAD BEARING AND NON-LOAD BEARING WALLS, AT ALL ABRUPT CHANGES IN HEIGHTS, AT ALL CHANGES IN WALL THICKNESS, AND AT ALL PILASTER LOCATIONS. VERIFY FINAL CONTROL JOINT LOCATIONS, WETHER OR NOT INDICATED ON THE DWGS, WITH ARCHITECT PRIOR TO STARTING WORK. 28. MECHANICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE ACCEPTABLE AND UNIFORM ENVIRONMENTAL CONDITIONS DURING CONSTRUCTION. 29. MECHANICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A COMPLETE MECHANICAL SYSTEM IN FULL COMPLIANCE WITH ALL APPLICABLE CODES. 30. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A COMPLETE ELECTRICAL SYSTEM IN FULL COMPLIANCE WITH ALL APPLICABLE CODES. GENERAL NOTES ARCHITECTURAL 1. PROVIDE WATER RESISTANT GWB IN ALL ROOMS CONTAINING OPERABLE PLUMBING FIXTURES AND WITHIN FOUR FEET OF DRINKING FOUNTAINS. 2. REFER TO SPECIFIC UNIT SHEETS FOR ANY "PREROCK" REQUIREMENTS AROUND BATH TUBS AND SHOWERS. INSTALL 1/2" CEMENT BOARD OR EQUAL BEHIND ALL TILE IN BATH TUBS AND SHOWERS 3. PROVIDE LATERAL BRACING FOR PARTITIONS WHICH EXTEND PAST CEILING HEIGHT. 4. WALL TYPE CONSTRUCTION TYPICALLY STARTS AT CONCRETE FLOOR ELEVATION OR WOOD FRAMED TOP OF SUBFLOOR. 5. REFER TO CODE DRAWINGS FOR ADDITIONAL INFORMATION. GENERAL NOTES WALL TYPES 1. THESE GENERAL NOTES APPLY TO REFLECTED CEILING PLAN DRAWINGS. 2. REFER TO THE 'PROJECT GENERAL NOTES' FOR ALL GENERAL NOTES APPLICABLE TO ALL DRAWINGS OF ALL DISCIPLINES. 3. CEILING HEIGHT DIMENSIONS ARE MEASURED TO FINISHED SURFACES, U.N.O. 4. ALL CEILINGS TO HAVE 58" TYPE 'C' GYPSUM BOARD WHERE REQUIRED FOR RATING AT INDICATED CEILING HEIGHT. 5. CENTER CEILING GRIDS WITHIN ROOM EACH DIRECTION, U.N.O. 6. LOCATE ACT CEILING GRIDS WITHIN ROOMS SUCH THAT THE BORDERS CONTAIN NOT LESS THAN 12 TILE WIDTH, U.N.O. 7. CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL CEILING PANELS, SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC., U.N.O. 8. PAINT ALL EXPOSED GYPSUM BOARD U.N.O. REF. FINISH PLANS FOR ADDITIONAL INFO. 9. PROVIDE CONTROL JOINTS (CJ) IN GYPSUM BOARD CEILING, MAX. CJ SPACING SHALL BE 30'-0", VERIFY FINAL CJ LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK. 10. CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT THE NUMBER OF PANELS REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE ALL REQUIRED ACCESS WHETHER OR NOT INDICATED ON THE DRAWINGS. VERIFY FINAL LOCATIONS WITH ARCHITECT PRIOR TO STARTING WORK. 11. REFER TO FINISH PLANS FOR ADDITIONAL CEILING INFORMATION. 12. REFER TO ELECTRICAL DRAWINGS FOR CEILING MOUNTED LIGHT FIXTURES TYPES AND QUANTITIES. USE ARCHITECTURAL REFLECTED CEILING PLANS FOR THE PLACEMENT OF LIGHT FIXTURES 13. REFER TO FIRE PROTECTION DRAWINGS FOR SPRINKLER HEAD TYPES AND QUANTITIES. HEADS HAVE BEEN INTENTIONALLY OMITTED FROM REFLECTED CEILING PLANS FOR CLARITY. 14. PROVIDE SOUND ATTENUATION INSULATION ABOVE CEILING AS INDICATED ON THE PLANS, SECTIONS, AND FLOOR/ROOF ASSEMBLIES. 15. COORDINATE LOCATION OF ALL ELEMENTS WITHIN HARD CEILING WITH ARCHITECT PRIOR TO INSTALLATION. 16. EXPOSED PERIMETER EDGES OF ACT CEILING TO BE FINISHED WITH SPECIFIED PERIMETER TRIM GENERAL NOTES REFLECTED CEILING PLAN 1. THESE GENERAL NOTES APPLY TO THE DOOR SCHEDULES. 2. DOOR AND FRAME NUMBERS CORRESPOND TO RESPECTIVE ROOM NUMBERS. IN ROOMS WITH MULTIPLE OPENINGS, A SUFFIX HAS BEEN ADDED TO DOOR NUMBERS. 3. VERTICAL FRAMING MEMBERS AT ALL DOOR FRAMES SHALL EXTEND TO STRUCTURE ABOVE. 4. UNDERCUT DOORS AS REQUIRED BY FINAL FINISH OR AS REQUIRED BY MECHANICAL ENGINEER 5. PROVIDE CONTINUOUS SEALANT BETWEEN HOLLOW METAL FRAME PERIMETERS AND SURROUNDING WALL CONSTRUCTION. 6. PROVIDE CONTINUOUS SEALANT BETWEEN INTERIOR AND EXTERIOR WINDOW, CURTAINWALL, AND STOREFRONT FRAME PERIMETERS AND SURROUNDING CONSTRUCTION, U.N.O. 7. GROUT FULL HOLLOW METAL FRAMES IN MASONRY CONSTRUCTION. 8. SPOT GROUT HOLLOW METAL FRAMES IN GYPSUM WALL. 9. WHERE A FIRE RATING IS INDICATED ON THE DOOR SCHEDULE, HARDWARE AND DOOR ASSEMBLY COMPONENTS SHALL MEET THE REQUIREMENTS OF THAT LABEL. 10. INSTALL DOOR GLASS USING WET-GLAZING METHOD. 11. ALL STEEL LINTELS ABOVE EXTERIOR OPENINGS SHALL BE GALVANIZED. GENERAL NOTES - WINDOW & DOORS ARCHITECTCLIENT CONSTRUCTION MANAGER PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20011 APRIL 28, 2021AVANT PHASE IICARMEL, INEDWARD ROSEDEVELOPMENTCARMEL LLC.PERMIT SET No. AR12000062 STATE OF MDXELA ARS H T E C TCHI AR STGI R E E DER IANDI N AGENERAL NOTES1. CONTRACTOR TO PROVIDE REQUIRED BLOCKING FOR CABINETS AND BATH ACCESSORIES 2. ALL BEDROOM CLOSETS TO HAVE DOUBLE SHELF AND ROD CONFIGURATION. 3. ALL COAT CLOSETS TO HAVE SINGLE SHELF AND ROD CONFIGURATION. 4. SEE MECHANICAL DRAWINGS FOR DRYER VENT INSTALLATION LOCATION 5. SEE MECHANICAL DRAWINGS FOR IN-WALL WATER CONNECTIONS 6. CONTRACTOR TO VERIFY SIZE AND FRAMING DIMENSIONS OF HVAC UNIT, BATHTUB, DOORS AND WINDOWS. 7. PROVIDE 1x2 PTD WOOD TRIM @ INTERIOR OF ALL CLOSETS / UTILITY CLOSETS WHERE STANDARD DOOR CASING WILL NOT FIT. 8. UNDERCUT ALL INTERIOR DOORS FOR RETURN AIR 1", VERIFY WITH MECHANICAL DRAWINGS. 9. ALL DRYWALL WET AREAS TO BE "GREEN" BOARD. 10. BASE OF MIRROR INSTALLED 40" AFF MAXIMUM. 11. PROVIDE DOOR VIEWER AT UNIT ENTRY DOORS 12. ALL CEILINGS ARE AT BOTTOM OF STRUCTURE (B.O.S.) IN UNITS U.N.O. 13. ALL FLOORING TRANSITIONS ARE TO BE CENTERED UNDER THE DOOR 14. REFER TO OVERALL PLANS FOR DEMISING / CORRIDOR WALL REQUIREMENTS. ALL WALLS / WALL SECTIONS BEHIND PLUMBING FIXTURES TO BE 2X6 MINIMUM. - FINISH WALLS TO ALIGN. 15. INTERIOR ELEVATIONS ARE FOR SCHEMATIC CABINET LAYOUT ONLY. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROVIDE FILLERS AS REQUIRED. REFER TO CABINET SHOP DRAWINGS AND OWNER SPECIFICATIONS. 16. FIELD VERIFY ALL CLOSET ELEVATIONS PRIOR TO FABRICATION & INSTALL. UNIT PLAN NOTES 10/11/21