HomeMy WebLinkAboutA021_INTERIOR WALL ASSEMBLIES434" 634"418" 2x4 WD. BOTTOM PLATE
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
1'-4" 1'-4"
2x6 WD. BOTTOM PLATE
2x6 WD. STUDS 16" 0.C.
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
1'-4" 1'-4"
1'-4" 1'-4"
2X4 WD. BOTTOM PLATE
2X4 WD. DBL. TOP PLATE
2X4 WD. STUDS 16" 0.C.
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' ONE SIDE
51116" UL DESIGNATION: U311 STC 52
1-HOUR FIRE PARTITION (IBC 708)
2x4 WD. BOTTOM PLATE
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
(1) LAYER 7/16" OSB ONE SIDE. SEE
STRUCTURAL SHEETS FOR LOCATION AND
NAILING PATTERN.
2x4 WD. DBL. TOP PLATE
SEE STRUCTURAL DWGS. SEE STRUCTURAL DWGS.
12" RESILIENT CHANNEL
2x6 WD. DBL. TOP PLATE 2x4 WD. DBL. TOP PLATE
UNIT SIDE
UNIT SIDE
CORRIDOR SIDE
3 1/2" SOUND ATTENUATION BATTS
*MIN STC 50
UNIT SIDE
914"SEE STRUCTURAL DWGS. SEE STRUCTURAL DWGS.
2X4 WD. BOTTOM PLATE
2X4 WD. STUDS AT 16" O.C.
3 1/2" SOUND ATTENUATION BLANKETS
FRICTION-FITTED TO COMPLETELY FILL THE
STUD CAVITIES
(1) LAYER 7/16" OSB. SEE STRUCTURAL
SHEETS FOR LOCATION AND NAILING
PATTERN
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
2X4 WD. DBL. TOP PLATE
UL DESIGNATION: U341 STC:56
1-HOUR FIRE PARTITION (IBC 708)
3" SOUND ATTENUATION BATTS
UNIT SIDE UNIT SIDE UNIT SIDE CORRIDOR SIDE
ACOUSTICAL SEALANT AT PERIMETER EACH SIDE
ACOUSTICAL SEALANT AT PERIMETER EACH SIDE ACOUSTICAL SEALANT AT
PERIMETER EACH SIDE
RATED SEALANT AT PERIMETER
EACH SIDE
FLOORING ASSEMBLY FLOORING ASSEMBLY
FLOORING ASSEMBLY FLOORING ASSEMBLYFLOORING ASSEMBLY
W6 W1W4 W2 W3 USE: TYPICAL CORRIDOR WALL
"p" INDICATES WALL HAS PLUMBING
CHANGE TO 2x6 FRAMING AND ALIGN INTERIOR SHEATHING
"a" INDICATES NON-SHEAR WALL
DELETE OSB AND ALIGN CORRIDOR SHEATHING
USE: UNIT DEMISING WALL
"p" INDICATES WALL HAS PLUMBING
CHANGE TO 2x6 FRAMING AND ALIGN INTERIOR SHEATHING
UNIT SIDE
UL DESIGNATION: U336, STC:60
2-HOUR AREA SEPARATION WALL (IBC 706)
W5 USE: 2-HR FIRE SEPARATION WALL
NOTES: "p" INDICATES WALL HAS PLUMBING
UNIT SIDE UNIT SIDE
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
2x4 WOOD DOUBLE TOP
PLATE
MIN. 3/4" AIR SPACE
(2) CONTINUOUS LAYERS 1"x24" TYPE 'X'
GYPSUM PANELS WITH STEEL H STUDS.
PROVIDE ALUMINUM CLIPS BETWEEN H STUDS
AND WALL FRAMING
2x4 WOOD STUDS- SEE STRUCTURAL FOR
DRAWINGS FOR SPACING
3 1/2" SOUND ATTENUATION BLANKETS
FRICTION-FITTED TO COMPLETELY FILL THE
STUD CAVITY
2x4 WOOD BOTTOM PLATE
FLOOR ASSEMBLY
1134"SEE STRUCTURAL DWGS.
UNIT SIDE
DRAFTSTOPPING
AS REQUIRED BY INDIANA BUILDING CODE,
EXCERPTS FROM SECT. 718
· DRAFTSTOPPING SHALL BE PROVIDED
IN FLOOR/CEILING SPACES IN... GROUP
R-2 BUILDINGS WITH (3) OR MORE
DWELLING UNITS... DRAFTSTOPPING
SHALL BE LOCATED ABOVE AND IN LINE
WITH DWELLING UNITS AND SLEEPING
UNITS
· IN OCCUPANCIES IN GROUP R-2 THAT DO
NOT EXCEED (4) STORIES ABOVE
GRADE PLANE, THE ATTIC SHALL BE
SUBDIVIDED BY DRAFTSTOPPING INTO
AREAS NOT EXCEEDING 3,000 SF OR
ABOVE EVERY (2) DWELLING UNITS,
WHICHEVER IS SMALLER.
THE PROVIDED DIAGRAM IS TO BE APPLIED
AT ALL ASSEMBLIES INDICATED.
58" TYPE 'X' GWB AS
DRAFTSTOPPING THROUGH
ATTIC SPACE
BLOCKING AS REQUIRED FOR
INSTALLATIONS
FIRE BLOCKING AT CEILING
LINES
ROOF TRUSSES, REFER TO
STRUCTURAL
REFER TO STRUCTURAL
DRAWINGS FOR SHEAR WALL
LOCATIONS AND
INFORMATION
PROVIDE FIRE BLOCKING AT
ALL FLOOR LINES
PROVIDE FIRE BLOCKING AT
ALL FLOOR LINES
FLOOR SHEATHING TO BE
CONTINUOUS ACROSS AIR
SPACE AT DEMISING WALLS
AND ACT AS DRAFTSTOPPING
EXTEND SHEATHING TO BOTTOM OF
FLOOR DECK- COORDINATE
DRAFTSTOPPING WITH STRUCTURAL
CONNECTION DETAIL
REFER TO STRUCTURAL
DRAWINGS FOR SHEAR WALL
LOCATIONS AND
INFORMATION
W4
W4
F1F2R1SHOWER/TUB
DETAILS
· STOP GREEN BOARD TUB/SHOWER SURROUND AT THE NEAREST
CHANGE OF DIRECTION OF WALLS ON THE SHORT SIDE OF
TUB/SHOWER
· CEMENTITIOUS UNDERLAYMENT, 34" MIN. UNDER TUB/SHOWER AND
IN DEAD AIR CAVITIES. THE SUBFLOORS MAY BE OVERLAID WITH
EITHER 34" MIN. CEMETITIOUS UNDERLAYMENT, 12" HOMASOTE
BOARD, 1532" MIN OSB OR PLYWOOD, OR 58" GP DENS GLASS
SHIELD FIRE GUARD TILE BACKER. CONSTRUCTION MUST MAINTAIN
UL L528 FLOOR ASSEMBLY.
· WHEN TUBS AND SHOWERS ARE LOCATED ALONG RATED WALL
ASSEMBLIES (UNIT DEMISING / CORRIDOR WALLS, ETC) THE
GREENBOARD CANNOT REPLACE THE 58" GYPSUM BOARD AS
PART OF THE RATED ASSEMBLY.
· INSTALL THE 58" GYPSUM AS PART OF THE RATED WALL
ASSEMBLY PRIOR TO THE INSTALLATION OF THE 58" GREENBOARD
AND TUB / SHOWER ASSEMBLY
58" GYPSUM GREEN BOARD TO EXTEND TO TOP
OF TUB / SHOWER PAN
SURROUND/SHOWER PAN TO BE MOUNTED TO
ALLOW REQUIRED RATED CEMENTITIOUS
UNDERLAYMENT. SEE NOTE ABOVE
BATHTUB / SHOWER PAN SURROUND
5'-17 8" CLR. FACE OF STUD
5'-0" CLR. FACE OF GREENBOARD
4'-114" CLR. FACE OF STUD
W1
W2
58" GYPSUM GREEN BOARD TO TOP OF TUB /
SHOWER PAN
SURROUND/SHOWER PAN TO BE MOUNTED TO
ALLOW REQUIRED RATED CEMENTITIOUS
UNDERLAYMENT. SEE NOTE ABOVE
BATHTUB / SHOWER PAN SURROUND
58" GYPSUM AS PART OF STANDARD INTERIOR
WALL TYPE- REFER TO UNIT PLANS
W4
58" GYPSUM GREEN BOARD TO EXTEND TO TOP
OF TUB / SHOWER PAN
SURROUND/SHOWER PAN TO BE MOUNTED TO
ALLOW REQUIRED RATED CEMENTITIOUS
UNDERLAYMENT. SEE NOTE ABOVE
BATHTUB / SHOWER PAN SURROUND
W3
1) STOP GREEN BOARD TUB/SHOWER SURROUND
AT THE NEAREST CHANGE OF DIRECTION OF
WALLS ON THE SHORT SIDE OF TUB/SHOWER.
TUB SURROUND INSERT / SHOWER TILE
58" GYPSUM AS PART OF STANDARD INTERIOR
WALL TYPE- REFER TO UNIT PLANS
TUB SURROUND INSERT / SHOWER TILE
TUB SURROUND INSERT / SHOWER TILE
4'-0" CLR. FACE OF GREENBOARD
LAYER 5
8"
GREENBOARD
OVER 58" GYPSUM
AS PART OF
RATED WALL
ASSEMBLY
UL DESIGNATION: U305, STC 33
1-HOUR FIRE PARTITION (IBC 708)
USE: TYPICAL UNIT INTERIOR WALL
"a" INDICATES ACOUSTIC WALL
ADD ACOUSTICAL INSULATION - STC 48 W/ INSULATION
"x" INDICATES 1-HR RATING
UL DESIGNATION: U379, STC N/A
1-HOUR FIRE PARTITION (IBC 708)
USE: TYPICAL UNIT INTERIOR WALL W/ PLUMBING
"a" INDICATES ACOUSTIC WALL
ADD ACOUSTICAL INSULATION - STC 48 W/ INSULATION
"x" INDICATES 1-HR RATING
USE: TYPICAL UNIT INTERIOR WALL FURRING WALL
"a" 2x4 WOD STUDS
"b" 2x6 WOOD FRAMING 618"1'-4" 1'-4"
W6a
W6b 8"2x6 WD. BOTTOM PLATE
2x6 WD. STUDS 16" 0.C.
(2) LAYERS 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
1'-4" 1'-4"
2x6 WD. DBL. TOP PLATE
FLOORING ASSEMBLY
W7
UL DESIGNATION: U301, STC 54
2-HOUR RATED ASSEMBLY
USE: LOAD BEARING WALLS AT AMENITY AREAS
"a" INDICATES 2x4 WOOD STUDS
SOUND ATTENUATION BATTS
W8
UNIT SIDE
AMENITY SIDE
1012"SEE STRUCTURAL DWGS. SEE STRUCTURAL DWGS.
2X4 WD. BOTTOM PLATE
2X4 WD. STUDS AT 16" O.C.
3 1/2" SOUND ATTENUATION BLANKETS
FRICTION-FITTED TO COMPLETELY FILL THE
STUD CAVITIES
(1) LAYER 7/16" OSB. SEE STRUCTURAL
SHEETS FOR LOCATION AND NAILING
PATTERN
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
2X4 WD. DBL. TOP PLATE
GA DESIGNATION: GA WP-3820 STC:56
2-HOUR FIRE RATED
ACOUSTICAL SEALANT AT PERIMETER EACH SIDE
ACOUSTICAL SEALANT AT PERIMETER EACH SIDE
FLOORING ASSEMBLY
USE: UNIT DEMISING WALL
"p" INDICATES WALL HAS PLUMBING
CHANGE TO 2x6 FRAMING AND ALIGN INTERIOR SHEATHING
STAIR LANDING SIDE
UL DESIGNATION: U336, STC:60
2-HOUR AREA SEPARATION WALL (IBC 706)
W9USE: 2-HR FIRE SEPARATION WALL @ STAIR TOWERS
"a" INDICATES 2X6 FRAMING ON BOTH SIDES
CORRIDOR SIDE STAIR LANDING SIDE
(1) LAYER 5/8" GYPSUM WALL
BOARD TYPE 'X' EACH SIDE
2x6 WOOD DOUBLE TOP
PLATE
MIN. 3/4" AIR SPACE
(2) CONTINUOUS LAYERS 1"x24" TYPE 'X'
GYPSUM PANELS WITH STEEL H STUDS.
PROVIDE ALUMINUM CLIPS BETWEEN H STUDS
AND WALL FRAMING
2x4 WOOD STUDS- SEE STRUCTURAL FOR
DRAWINGS FOR SPACING
3 1/2" SOUND ATTENUATION BLANKETS
FRICTION-FITTED TO COMPLETELY FILL THE
STUD CAVITY
2x6 WOOD BOTTOM PLATE
FLOOR ASSEMBLY
1'-134"SEE STRUCTURAL DWGS.
UNIT CORRIDOR SIDE
A021 ARCHITECTCLIENT CONSTRUCTION MANAGER PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20011
APRIL 28, 2021AVANT PHASE IICARMEL, INEDWARD ROSEDEVELOPMENTCARMEL LLC.PERMIT SET
No. AR12000062
STATE OF
MDXELA
ARS
H
T E C TCHI
AR
STGI
R E E
DER
IANDI N AINTERIOR WALLASSEMBLIES10/11/21