Loading...
HomeMy WebLinkAboutA021_INTERIOR WALL ASSEMBLIES434" 634"418" 2x4 WD. BOTTOM PLATE (1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X' EACH SIDE 1'-4" 1'-4" 2x6 WD. BOTTOM PLATE 2x6 WD. STUDS 16" 0.C. (1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X' EACH SIDE 1'-4" 1'-4" 1'-4" 1'-4" 2X4 WD. BOTTOM PLATE 2X4 WD. DBL. TOP PLATE 2X4 WD. STUDS 16" 0.C. (1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X' ONE SIDE 51116" UL DESIGNATION: U311 STC 52 1-HOUR FIRE PARTITION (IBC 708) 2x4 WD. BOTTOM PLATE (1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X' EACH SIDE (1) LAYER 7/16" OSB ONE SIDE. SEE STRUCTURAL SHEETS FOR LOCATION AND NAILING PATTERN. 2x4 WD. DBL. TOP PLATE SEE STRUCTURAL DWGS. SEE STRUCTURAL DWGS. 12" RESILIENT CHANNEL 2x6 WD. DBL. TOP PLATE 2x4 WD. DBL. TOP PLATE UNIT SIDE UNIT SIDE CORRIDOR SIDE 3 1/2" SOUND ATTENUATION BATTS *MIN STC 50 UNIT SIDE 914"SEE STRUCTURAL DWGS. SEE STRUCTURAL DWGS. 2X4 WD. BOTTOM PLATE 2X4 WD. STUDS AT 16" O.C. 3 1/2" SOUND ATTENUATION BLANKETS FRICTION-FITTED TO COMPLETELY FILL THE STUD CAVITIES (1) LAYER 7/16" OSB. SEE STRUCTURAL SHEETS FOR LOCATION AND NAILING PATTERN (1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X' EACH SIDE 2X4 WD. DBL. TOP PLATE UL DESIGNATION: U341 STC:56 1-HOUR FIRE PARTITION (IBC 708) 3" SOUND ATTENUATION BATTS UNIT SIDE UNIT SIDE UNIT SIDE CORRIDOR SIDE ACOUSTICAL SEALANT AT PERIMETER EACH SIDE ACOUSTICAL SEALANT AT PERIMETER EACH SIDE ACOUSTICAL SEALANT AT PERIMETER EACH SIDE RATED SEALANT AT PERIMETER EACH SIDE FLOORING ASSEMBLY FLOORING ASSEMBLY FLOORING ASSEMBLY FLOORING ASSEMBLYFLOORING ASSEMBLY W6 W1W4 W2 W3 USE: TYPICAL CORRIDOR WALL "p" INDICATES WALL HAS PLUMBING CHANGE TO 2x6 FRAMING AND ALIGN INTERIOR SHEATHING "a" INDICATES NON-SHEAR WALL DELETE OSB AND ALIGN CORRIDOR SHEATHING USE: UNIT DEMISING WALL "p" INDICATES WALL HAS PLUMBING CHANGE TO 2x6 FRAMING AND ALIGN INTERIOR SHEATHING UNIT SIDE UL DESIGNATION: U336, STC:60 2-HOUR AREA SEPARATION WALL (IBC 706) W5 USE: 2-HR FIRE SEPARATION WALL NOTES: "p" INDICATES WALL HAS PLUMBING UNIT SIDE UNIT SIDE (1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X' EACH SIDE 2x4 WOOD DOUBLE TOP PLATE MIN. 3/4" AIR SPACE (2) CONTINUOUS LAYERS 1"x24" TYPE 'X' GYPSUM PANELS WITH STEEL H STUDS. PROVIDE ALUMINUM CLIPS BETWEEN H STUDS AND WALL FRAMING 2x4 WOOD STUDS- SEE STRUCTURAL FOR DRAWINGS FOR SPACING 3 1/2" SOUND ATTENUATION BLANKETS FRICTION-FITTED TO COMPLETELY FILL THE STUD CAVITY 2x4 WOOD BOTTOM PLATE FLOOR ASSEMBLY 1134"SEE STRUCTURAL DWGS. UNIT SIDE DRAFTSTOPPING AS REQUIRED BY INDIANA BUILDING CODE, EXCERPTS FROM SECT. 718 · DRAFTSTOPPING SHALL BE PROVIDED IN FLOOR/CEILING SPACES IN... GROUP R-2 BUILDINGS WITH (3) OR MORE DWELLING UNITS... DRAFTSTOPPING SHALL BE LOCATED ABOVE AND IN LINE WITH DWELLING UNITS AND SLEEPING UNITS · IN OCCUPANCIES IN GROUP R-2 THAT DO NOT EXCEED (4) STORIES ABOVE GRADE PLANE, THE ATTIC SHALL BE SUBDIVIDED BY DRAFTSTOPPING INTO AREAS NOT EXCEEDING 3,000 SF OR ABOVE EVERY (2) DWELLING UNITS, WHICHEVER IS SMALLER. THE PROVIDED DIAGRAM IS TO BE APPLIED AT ALL ASSEMBLIES INDICATED. 58" TYPE 'X' GWB AS DRAFTSTOPPING THROUGH ATTIC SPACE BLOCKING AS REQUIRED FOR INSTALLATIONS FIRE BLOCKING AT CEILING LINES ROOF TRUSSES, REFER TO STRUCTURAL REFER TO STRUCTURAL DRAWINGS FOR SHEAR WALL LOCATIONS AND INFORMATION PROVIDE FIRE BLOCKING AT ALL FLOOR LINES PROVIDE FIRE BLOCKING AT ALL FLOOR LINES FLOOR SHEATHING TO BE CONTINUOUS ACROSS AIR SPACE AT DEMISING WALLS AND ACT AS DRAFTSTOPPING EXTEND SHEATHING TO BOTTOM OF FLOOR DECK- COORDINATE DRAFTSTOPPING WITH STRUCTURAL CONNECTION DETAIL REFER TO STRUCTURAL DRAWINGS FOR SHEAR WALL LOCATIONS AND INFORMATION W4 W4 F1F2R1SHOWER/TUB DETAILS · STOP GREEN BOARD TUB/SHOWER SURROUND AT THE NEAREST CHANGE OF DIRECTION OF WALLS ON THE SHORT SIDE OF TUB/SHOWER · CEMENTITIOUS UNDERLAYMENT, 34" MIN. UNDER TUB/SHOWER AND IN DEAD AIR CAVITIES. THE SUBFLOORS MAY BE OVERLAID WITH EITHER 34" MIN. CEMETITIOUS UNDERLAYMENT, 12" HOMASOTE BOARD, 1532" MIN OSB OR PLYWOOD, OR 58" GP DENS GLASS SHIELD FIRE GUARD TILE BACKER. CONSTRUCTION MUST MAINTAIN UL L528 FLOOR ASSEMBLY. · WHEN TUBS AND SHOWERS ARE LOCATED ALONG RATED WALL ASSEMBLIES (UNIT DEMISING / CORRIDOR WALLS, ETC) THE GREENBOARD CANNOT REPLACE THE 58" GYPSUM BOARD AS PART OF THE RATED ASSEMBLY. · INSTALL THE 58" GYPSUM AS PART OF THE RATED WALL ASSEMBLY PRIOR TO THE INSTALLATION OF THE 58" GREENBOARD AND TUB / SHOWER ASSEMBLY 58" GYPSUM GREEN BOARD TO EXTEND TO TOP OF TUB / SHOWER PAN SURROUND/SHOWER PAN TO BE MOUNTED TO ALLOW REQUIRED RATED CEMENTITIOUS UNDERLAYMENT. SEE NOTE ABOVE BATHTUB / SHOWER PAN SURROUND 5'-17 8" CLR. FACE OF STUD 5'-0" CLR. FACE OF GREENBOARD 4'-114" CLR. FACE OF STUD W1 W2 58" GYPSUM GREEN BOARD TO TOP OF TUB / SHOWER PAN SURROUND/SHOWER PAN TO BE MOUNTED TO ALLOW REQUIRED RATED CEMENTITIOUS UNDERLAYMENT. SEE NOTE ABOVE BATHTUB / SHOWER PAN SURROUND 58" GYPSUM AS PART OF STANDARD INTERIOR WALL TYPE- REFER TO UNIT PLANS W4 58" GYPSUM GREEN BOARD TO EXTEND TO TOP OF TUB / SHOWER PAN SURROUND/SHOWER PAN TO BE MOUNTED TO ALLOW REQUIRED RATED CEMENTITIOUS UNDERLAYMENT. SEE NOTE ABOVE BATHTUB / SHOWER PAN SURROUND W3 1) STOP GREEN BOARD TUB/SHOWER SURROUND AT THE NEAREST CHANGE OF DIRECTION OF WALLS ON THE SHORT SIDE OF TUB/SHOWER. TUB SURROUND INSERT / SHOWER TILE 58" GYPSUM AS PART OF STANDARD INTERIOR WALL TYPE- REFER TO UNIT PLANS TUB SURROUND INSERT / SHOWER TILE TUB SURROUND INSERT / SHOWER TILE 4'-0" CLR. FACE OF GREENBOARD LAYER 5 8" GREENBOARD OVER 58" GYPSUM AS PART OF RATED WALL ASSEMBLY UL DESIGNATION: U305, STC 33 1-HOUR FIRE PARTITION (IBC 708) USE: TYPICAL UNIT INTERIOR WALL "a" INDICATES ACOUSTIC WALL ADD ACOUSTICAL INSULATION - STC 48 W/ INSULATION "x" INDICATES 1-HR RATING UL DESIGNATION: U379, STC N/A 1-HOUR FIRE PARTITION (IBC 708) USE: TYPICAL UNIT INTERIOR WALL W/ PLUMBING "a" INDICATES ACOUSTIC WALL ADD ACOUSTICAL INSULATION - STC 48 W/ INSULATION "x" INDICATES 1-HR RATING USE: TYPICAL UNIT INTERIOR WALL FURRING WALL "a" 2x4 WOD STUDS "b" 2x6 WOOD FRAMING 618"1'-4" 1'-4" W6a W6b 8"2x6 WD. BOTTOM PLATE 2x6 WD. STUDS 16" 0.C. (2) LAYERS 5/8" GYPSUM WALL BOARD TYPE 'X' EACH SIDE 1'-4" 1'-4" 2x6 WD. DBL. TOP PLATE FLOORING ASSEMBLY W7 UL DESIGNATION: U301, STC 54 2-HOUR RATED ASSEMBLY USE: LOAD BEARING WALLS AT AMENITY AREAS "a" INDICATES 2x4 WOOD STUDS SOUND ATTENUATION BATTS W8 UNIT SIDE AMENITY SIDE 1012"SEE STRUCTURAL DWGS. SEE STRUCTURAL DWGS. 2X4 WD. BOTTOM PLATE 2X4 WD. STUDS AT 16" O.C. 3 1/2" SOUND ATTENUATION BLANKETS FRICTION-FITTED TO COMPLETELY FILL THE STUD CAVITIES (1) LAYER 7/16" OSB. SEE STRUCTURAL SHEETS FOR LOCATION AND NAILING PATTERN (1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X' EACH SIDE 2X4 WD. DBL. TOP PLATE GA DESIGNATION: GA WP-3820 STC:56 2-HOUR FIRE RATED ACOUSTICAL SEALANT AT PERIMETER EACH SIDE ACOUSTICAL SEALANT AT PERIMETER EACH SIDE FLOORING ASSEMBLY USE: UNIT DEMISING WALL "p" INDICATES WALL HAS PLUMBING CHANGE TO 2x6 FRAMING AND ALIGN INTERIOR SHEATHING STAIR LANDING SIDE UL DESIGNATION: U336, STC:60 2-HOUR AREA SEPARATION WALL (IBC 706) W9USE: 2-HR FIRE SEPARATION WALL @ STAIR TOWERS "a" INDICATES 2X6 FRAMING ON BOTH SIDES CORRIDOR SIDE STAIR LANDING SIDE (1) LAYER 5/8" GYPSUM WALL BOARD TYPE 'X' EACH SIDE 2x6 WOOD DOUBLE TOP PLATE MIN. 3/4" AIR SPACE (2) CONTINUOUS LAYERS 1"x24" TYPE 'X' GYPSUM PANELS WITH STEEL H STUDS. PROVIDE ALUMINUM CLIPS BETWEEN H STUDS AND WALL FRAMING 2x4 WOOD STUDS- SEE STRUCTURAL FOR DRAWINGS FOR SPACING 3 1/2" SOUND ATTENUATION BLANKETS FRICTION-FITTED TO COMPLETELY FILL THE STUD CAVITY 2x6 WOOD BOTTOM PLATE FLOOR ASSEMBLY 1'-134"SEE STRUCTURAL DWGS. UNIT CORRIDOR SIDE A021 ARCHITECTCLIENT CONSTRUCTION MANAGER PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20011 APRIL 28, 2021AVANT PHASE IICARMEL, INEDWARD ROSEDEVELOPMENTCARMEL LLC.PERMIT SET No. AR12000062 STATE OF MDXELA ARS H T E C TCHI AR STGI R E E DER IANDI N AINTERIOR WALLASSEMBLIES10/11/21