Loading...
HomeMy WebLinkAboutSite Plan 03-29-221-STY BRICK AND FRAME COMMERCIAL BUILDING C C C C C C C C C C C C C C C CCC C 6" STORM -PREFERREDLOCATION4" FOODWASTE4" SANWASTEGAS SERVICECT CABSTORM DROP FROM ROOF -PREFERRED LOCATIONTHIS AREA IS FOR MENU BOARDS AND OCB ONLY.NO UNDERGROUND GREASE TRAPS OR ABOVEGROUND ELECTRICAL TRANSFORMERS; SEE SITEPLAN FROM CFS.VERIFY ALL UNDERGROUND WORK THIS AREA w/SIGN CONTRACTOR.FIRE PROTECTION 2" WATER SERVICEFDC DIRECT CONNECTIONSFOR VENDORSPICKUP WINDOW18.0'18.0'1.0'11.5'2.0'18.0'9.0 ' 18.0' 18.0'9.0'9.0 '8.0 ' 18.0'R3.0'R10.0'R3 . 0 ' R1 8 . 0 '18.0'9.0'R3.0'R5.0'R3.0'25.0'9.0'15.0'9.0' 16.5'3.0'7 4 14 8 10 3 9.0'9.0'18.0'R1 0 . 0 'R2 0 . 0 ' R3.0' 9.0'19.0'9.0'37.3'8.9' 9.0' 9.0' 9.3'14.2'8.0 '8.0 '9.0 ' 18.0'282.3'47.7' 40.4'3.0' 0.7' 3.0' 0.7'14.0'R10.0'73.2'14.4'151.3'64.0'R5.0'R3 . 0 '124.9'5.0' 5.0' 101.7'84.7'R5 . 0 ' 5.9'124.2'R5.0'1.0'5.0'FFE = 834.00 R2.0'R2. 0 '60°'11.0' 6.0'5.0'14.0'104.0'35.0'125.1'54.4' ST ST ST 5.2'6.0' 5.2'6.0'4.5'5.0'4.5'8.5'23.0'6 0 ° ' 60°' 6 0 ° '23.3'153.9'13.0' 1.0' 16.5' ST 30.0'R20.0'15.5'R10.0'3.0'28.8'19.3' SITE DATA SITE AREA = 1.16 AC SITE AREA = 50,466 SF BUILDING AREA = 5,558 SF HARDSCAPE AREA = 28,917 SF GREEN SPACE = 15,991 SF PERCENT IMPERVIOUS = 68.3% ZONING = B-8 FRONT BSL = 25 FT SIDE BSL = 10 FT MAX BUILDING HEIGHT = 50 FT PARKING PROVIDED: STANDARD SPACES:44 ADA SPACES:2 TOTAL SPACES:46 RIGHT OF WAY LINE FENCE GUARD RAIL BUILDING SETBACK LINE BOUNDARY LINE FLAG POLE SIGN ACCESSIBLE SPACE ROW RIGHT OF WAY BSL BUILDING SETBACK LINE ESMT EASEMENT D.&U.E.DRAINAGE AND UTILITY EASEMENT FFE FINISH FLOOR ELEVATION 12 PARKING COUNT ABBREVIATIONS OTHER LINE TYPES SECTION LINE SITE PLAN NOTES PAVEMENT - DETAILS SHEET C8.1 BITUMINOUS PAVING FOR PARKING LOT (STANDARD DUTY ASPHALT PAVEMENT SECTION) - 165#/SQ YD (1 1/2") BITUMINOUS SURFACE OVER 275#/SQ YD (2 1/2") BITUMINOUS BINDER OVER 8" COMPACTED AGGREGATE BASE #53 (100% STANDARD PROCTOR) BITUMINOUS PAVING FOR PARKING LOT (HEAVY DUTY ASPHALT PAVEMENT SECTION) - 220#/SQ YD (2") BITUMINOUS SURFACE OVER 330#/SQ YD (3") BITUMINOUS BINDER OVER 8" COMPACTED AGGREGATE BASE #53 (100% STANDARD PROCTOR) CONCRETE PAVING AT DRIVE THRU, 10' WIDE X 5" THICK, 4500 PSI WITH INTEGRAL LOOP DETECTOR AT CUSTOMER ORDER DISPLAY, SEE ELECTRICAL PLANS FOR DETECTOR SPECS CONCRETE PAVING AT DUMPSTER (HEAVY DUTY CONCRETE PAVEMENT SECTION) - 8" THICK 4500 PSI WITH 5% AIR ENTRAINMENT OVER 6" CA BASE PAVER WALKWAY - PAVERS LAID OVER 4" 4000 PSI REINFORCED CONCRETE OVER 4" COMPACTED AGGREGATE BASE #53 (100% STANDARD PROCTOR) 2% MAXIMUM CROSS SLOPE (1.5% RECOMMENDED) 5% MAXIMUM RUNNING SLOPE (4.5% RECOMMENDED) 4" THICK CONCRETE CURB RAMP WITH NON-SLIP SURFACE PER ADA STANDARDS 8.33% MAXIMUM RUNNING SLOPE (7.75% RECOMMENDED) 2% MAXIMUM CROSS SLOPE (1.5% RECOMMENDED) 4" THICK x 5' WIDE CONCRETE WALKWAY 2% MAXIMUM CROSS SLOPE (1.5% RECOMMENDED) 5% MAXIMUM RUNNING SLOPE (4.5% RECOMMENDED) HARDSCAPE - DETAILS SHEET C8.1 6" X 18" STANDARD CONCRETE CURB TAPER CURB WITHIN 3 FEET MATCH EXISTING PAVEMENT CONCRETE COLLAR BUILDING ACCESSORIES - DETAILS SHEET 8.20 PROPOSED BUILDING DUMPSTER ENCLOSURE WITH STORAGE SHED DRIVE THROUGH CANOPY ACCESSORIES 6" CONCRETE BOLLARD LED LOT LIGHT AND BASE (DETAILS SHEET 8.21) LOOP DETECTOR IN CONCRETE PAVEMENT (SEE MEP PLANS FOR SPECIFICATIONS) BICYCLE RACK SIGNAGE & MARKINGS 9' WIDE PARKING SPACE (CTR TO CTR PAINT STRIPE) MARKED WITH 4" WIDE YELLOW PAINT STRIPE (PMS 123) 9'-0" WIDE ACCESSIBLE PARKING SPACE (CTR TO CTR PAINT STRIPE) MARKED WITH BLUE PAINT HANDICAP GRAPHIC & 4" WIDE BLUE PAINT STRIPE 8' WIDE (MIN) ACCESSIBLE AISLE (CTR TO CTR PAINT STRIPE) MARKED WITH 4" BLUE PAINT STRIPE PEDESTRIAN PATH PAVEMENT MARKINGS - YELLOW (PMS 123) DIRECTIONAL PAVEMENT MARKINGS - YELLOW (PMS 123) BOLLARD MOUNTED VAN ACCESSIBLE PARKING SIGN (MIN HEIGHT TO BOTTOM OF SIGN 66" ABOVE PAVEMENT) BOLLARD MOUNTED ACCESSIBLE PARKING SIGN (OVERALL HEIGHT TO MATCH VAN ACCESSIBLE PARKING SIGN) 6" CONCRETE BOLLARD BOLLARD MOUNTED CURBSIDE PICKUP SIGN (OVERALL HEIGHT TO MATCH VAN ACCESSIBLE PARKING SIGN) H1 H2 B1 A1 A2 A4 P1 P2 P3 P4 P5 P6 S1 S2 S3 S4 S5 S6 S7 S8 H3 A3 H4 C3.0SITE PLANREVISIONS AND ISSUESPREPARED FOR:PROJECT NO. SHEET NO.CHECKED BY:DRAWN BY:DEGDESIGNED BY:DWG NAME:PROJECT NO.:W220058DATEBY01.31.2022BTDATE:DEGENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMA PART OF THE SOUTHWEST QUARTER, SECTION 31, TOWNSHIP 18 NORTH, RANGE 4 EAST, HAMILTON COUNTY, INDIANAW22.0058431 E CARMEL DRIVE, CARMEL, IN 46032Know what's below. before you dig.Call R CULVER'SCARMEL, INW S N E S9 B2 P1 P6 P1 P1 P1 P1 P1 P1 P1 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P3 P3 P4 P7 P7 P7 H1 H1 H1 H1 H1 H1 H1 H1 H1 H1 H1 H2 H2 H2 H3 H3 B2 B1 S1 S1 S1 S1 S1 S1 S2 S2 S3 S4S6 S7 S9 S8 S8 B3 B3 A4 H4 H4 H4 H4 H4 H5 P2 S1 P2 P4 P5 P5 P5 P5 P5 H1 H1 H4 S5 S5 S5 S5 S5 S5 S5 H4