Loading...
HomeMy WebLinkAboutA10114'-0"8'-0"8'-0"11'-0"14'-0"16'-4"14'-0"10'-1116"7'-11 18"7'-1158" 16'-234"16'-1516"43'-212"66'-7"16'-2 34" 12'-71116"9'-058"6'-858"17'-5"6'-0"6'-0"6'-0"2'-0"2'-0"5 4 W1AW1AW1AW1AW1AW1AW1A W1AW1A W1A W1A W1A W1A W1A 116CHAMPAGNEBAR 117CORRIDOR 115DRESSING 120STORAGE 114FAMILY 113DRESSING 111FAMILY 112FAMILY 110DRESSING 109DRESSING 108FAMILY 107FAMILY 105DRESSING 106DRESSING 104FAMILYROOM 103RETAIL SPACE 101RECEPTION 119RESTROOM 118RESTROOM 8'-11"4'-11"2 A102 105 106109 110113 1151181191166'-0"6'-0"6'-4" 26 7 1 1 1 1 1 W1A 100 100VESTIBULE 7'-0"6'-9"8 9 1 FLOOR PLAN SCALE: 3/16" = 1'-0" A. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS AND JOB CONDITIONS. ANY DEVIATION FROM WHAT IS NOTED IN DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. B. ALL DIMENSIONS SHOWN ARE FACE OF BRICK, MASONRY OR METAL STUD FRAMING, UNLESS OTHERWISE NOTED. C. PROVIDE DEEP LEG DEFLECTION TRACK AT ALL METAL STUD CONNECTIONS WITH STRUCTURE ABOVE, TYPICAL. D. PROVIDE FIRE RATED WOOD BLOCKING IN METAL STUD WALLS FOR ANY WALL SUPPORTED ITEMS. E. PROVIDE APPROVED FIRE RATED STOPPING MATERIALS IN ANY OPENINGS IN FIRE RATED ASSEMBLIES. F. REFER TO DOOR AND WINDOW SCHEDULES FOR ALL MATERIALS, FINISHES, AND HARDWARE INFORMATION. G. REFER TO EXTERIOR ELEVATIONS FOR ALL BRICK, MASONRY, AND OTHER EXPANSION JOINT LOCATIONS. H. ALL MATERIALS LOCATED IN CEILING PLENUM SHALL BE RATED FOR SUCH INSTALLATION OR PROTECTED TO PROVIDE COMPLIANCE. THIS INCLUDES BUT IS NOT LIMITED TO INSULATION (FHC 25/50) POWER AND LOW VOLTAGE WIRING, TELECOMMUNICATIONS CABLING, PLUMBING SUPPLY AND DRAIN LINES AND SUPPORTING BRACKETS AND/OR BLOCKING FOR CEILING HUNG ITEMS. I. PRIOR TO ORDERING ANY PRODUCTS, CONTRACTOR SHALL SUBMIT SAMPLES TO THE ARCHITECT OF ALL FINISH MATERIALS TO BE USED ON THE PROJECT. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR ANY MATERIALS ORDERED INCORRECTLY WHEN THAT MATERIAL WAS NOT REVIEWED BY THE ARCHITECT. J. PROVIDE CONCRETE FILLED STEEL PIPE BOLLARDS AT ALL REQUIRED UTILITY EQUIPMENT LOCATIONS SUCH AS GAS METERS, ELECTRICAL TRANSFORMER PANELS, ETC., COORDINATE WITH UTILITY COMPANY AND CONTRACTORS, WHEN APPLICABLE, FOR NECESSARY LOCATIONS. REFER TO CIVIL DRAWINGS FOR BOLLARD SPECIFICATIONS AND ADDITIONAL INFORMATION. K. ALL DOORS, UNLESS OTHERWISE NOTED, TO HAVE HINGE SIDE SET 4" FROM CORNER SHOWN TO OUTSIDE OF FRAME. L. UNLESS SPECIFIED ELSEWHERE, ALL INTERIOR SLABS AND SLAB INFILLS TO BE FF-50/FL-35 OVERALL AND FF-35/FL-25 LOCAL. M. ALL EXIT DOORS TO HAVE TACTILE EXIT SIGNAGE PER 703.4 OF THE ANSI 117.1 2009 GENERAL NOTES 1. PROVIDE ARCHED DRYWALL WRAPPED OPENING. SPRINGLINE OF ARCH @ 7'-0" AND HIGH POINT @ 8'-0" AFF. PROVIDE BLOCKING ON FAMILY ROOM SIDE OF WALL FOR TENANT PROVIDED/INSTALLED PRIVACY CURTAIN. 2. INFILL W/ WALKOFF CARPET TILE. PROVIDE LEVELING COMPOUND FOR FLUSH INSTALLATION W/ ADJACENT FLOORING. 3. BOX OUT 1/2 NON-STRUCTURAL COLUMN TO MATCH ADJACENT EXISTING FURRED OUT STRUCTURAL COLUMN. REPEAT IN ALL NOTED LOCATIONS. 4. EXISTING STOREFRONT TO REMAIN . REPAIR AS REQUIRED 5. ALIGN AND MATCH WITH EXISTING WALL BUMP OUT IN WIDTH, HEIGHT, CONSTRUCTION, MATERIAL, AND FINISH. 6. TRANSACTION AREA FINAL DESIGN TO BE DETERMINED. DESIGN TO PROVIDE MINIMUM OF 36" WIDTH OF TRANSACTION COUNTER AT 2'-10" FOR ADA COMPLIANCE. COORDINATE WITH TENANT ON DESIGN AND FINISH MATERIALS. 7. INFILL TILE TO MATCH AS REQUIRED. TYP ALONG DEMISING WALL. 8. STOREFRONT FRAMING TO MATCH EXISTING. REFER TO STOREFRONT ELEVATIONS FOR MORE INFORMATION. 9. FIBERGLASS MOP SINK WITH WALL MOUNTED FAUCET. PROVIDE FRP ON WALLS FROM FLOOR TO 48" AFF BEHIND SINK AND TO MIN. 2' PAST SINK EACH WAY. KEYED NOTES KEY PLAN PERMIT SET 11.23.21 PROJECT NUMBER: 210279 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. © COPYRIGHT 2021, CURRAN ARCHITECTURE PROJECT INFORMATION CERTIFICATION ISSUE DATES F :: 317 . 288 . 0753 O :: 317 . 288 . 0681 INDIANAPOLIS, IN 46216 5719 LAWTON LOOP E. DR. #212 THE WEDDING STUDIO AT CLAY TERRACE 14550 CLAY TERRACE BLVDCARMEL, IN 46032 N CLAY TERRACE BLVDFLOOR PLAN A101 N7'-0"03/31/22