HomeMy WebLinkAboutA102SD1 TT1 GB2 M1 TD1 2 3 GB1 GB1 SD1 TT1 GB2 M1 TD1 2 3GB1 GB1 1 W1AW2AW2A W2AW2A 116 CHAMPAGNE BAR 117CORRIDOR 119RESTROOM 118RESTROOM 1181191 A102 7'-10"7'-134" 6'-10 116"1163'-8 14" 7'-014" 2'-6"2'-0"2'-8"1'-1"SEE ELEVATIONS4"2'-1" 112"2" PROVIDE MATCHING FALSE DRAWER AT ALL SINK LOCATIONS. MATCH ALL FINISHES, HARDWARE, ETC COUNTER TOP WITH TURNED DOWN FRONT LIP PROVIDE 4" HIGH BACKSPLASH AND SIDESPLASHES WHERE COUNTER ABUTS SIDE WALLS. SEE ELEVATIONS TYPICAL BASE CABINET WITH NO SHELVING OR STANDARDSSEE ELEVATIONSSEE ELEVATIONS1'-0" PROVIDE WHITE MELAMINE FOR ALL INTERIOR CABINET FINISHES. TYPICAL UNLESS NOTED OTHERWISE 2 ENLARGED RESTROOM PLAN SCALE: 3/4" = 1'-0" A. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS AND JOB CONDITIONS. ANY DEVIATION FROM WHAT IS NOTED IN DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. B. ALL DIMENSIONS SHOWN ARE FACE OF BRICK, MASONRY OR METAL STUD FRAMING, UNLESS OTHERWISE NOTED. C. PROVIDE DEEP LEG DEFLECTION TRACK AT ALL METAL STUD CONNECTIONS WITH STRUCTURE ABOVE, TYPICAL. D. PROVIDE FIRE RATED WOOD BLOCKING IN METAL STUD WALLS FOR ANY WALL SUPPORTED ITEMS. E. PROVIDE APPROVED FIRE RATED STOPPING MATERIALS IN ANY OPENINGS IN FIRE RATED ASSEMBLIES. F. REFER TO DOOR AND WINDOW SCHEDULES FOR ALL MATERIALS, FINISHES, AND HARDWARE INFORMATION. G. REFER TO EXTERIOR ELEVATIONS FOR ALL BRICK, MASONRY, AND OTHER EXPANSION JOINT LOCATIONS. H. ALL MATERIALS LOCATED IN CEILING PLENUM SHALL BE RATED FOR SUCH INSTALLATION OR PROTECTED TO PROVIDE COMPLIANCE. THIS INCLUDES BUT IS NOT LIMITED TO INSULATION (FHC 25/50) POWER AND LOW VOLTAGE WIRING, TELECOMMUNICATIONS CABLING, PLUMBING SUPPLY AND DRAIN LINES AND SUPPORTING BRACKETS AND/OR BLOCKING FOR CEILING HUNG ITEMS. I. PRIOR TO ORDERING ANY PRODUCTS, CONTRACTOR SHALL SUBMIT SAMPLES TO THE ARCHITECT OF ALL FINISH MATERIALS TO BE USED ON THE PROJECT. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR ANY MATERIALS ORDERED INCORRECTLY WHEN THAT MATERIAL WAS NOT REVIEWED BY THE ARCHITECT. J. PROVIDE CONCRETE FILLED STEEL PIPE BOLLARDS AT ALL REQUIRED UTILITY EQUIPMENT LOCATIONS SUCH AS GAS METERS, ELECTRICAL TRANSFORMER PANELS, ETC., COORDINATE WITH UTILITY COMPANY AND CONTRACTORS, WHEN APPLICABLE, FOR NECESSARY LOCATIONS. REFER TO CIVIL DRAWINGS FOR BOLLARD SPECIFICATIONS AND ADDITIONAL INFORMATION. K. ALL DOORS, UNLESS OTHERWISE NOTED, TO HAVE HINGE SIDE SET 4" FROM CORNER SHOWN TO OUTSIDE OF FRAME. L. UNLESS SPECIFIED ELSEWHERE, ALL INTERIOR SLABS AND SLAB INFILLS TO BE FF-50/FL-35 OVERALL AND FF-35/FL-25 LOCAL. M. ALL EXIT DOORS TO HAVE TACTILE EXIT SIGNAGE PER 703.4 OF THE ANSI 117.1 2009 GENERAL NOTES 1. NEW ADA COMPLIANT STAINLESS STEEL UNDERMOUNT SINK W/ LEVER FAUCET. PROVIDE SCALD GUARDS ON ALL PIPES. SEE A002 FOR FIXTURE HEIGHT. 2. NEW ADA COMPLIANT WALL MOUNTED LAVATORY. PROVIDE SCALD GUARDS ON ALL PIPES. SEE A002 FOR FIXTURE HEIGHT. 3. NEW ADA COMPLIANT TANK TYPE TOILET. SEE A002 FOR FIXTURE HEIGHT. KEYED NOTES KEY PLAN PERMIT SET 11.23.21 PROJECT NUMBER: 210279 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. © COPYRIGHT 2021, CURRAN ARCHITECTURE PROJECT INFORMATION CERTIFICATION ISSUE DATES F :: 317 . 288 . 0753 O :: 317 . 288 . 0681 INDIANAPOLIS, IN 46216 5719 LAWTON LOOP E. DR. #212 THE WEDDING STUDIO AT CLAY TERRACE 14550 CLAY TERRACE BLVDCARMEL, IN 46032 N CLAY TERRACE BLVDENLARGED RESTROOM PLAN A102 TOILET ACCESSORY SCHEDULE MARK SYMBOL MFR #DESCRIPTION TT1 BOBRICK B-2888 MULTI-ROLL TOILET TISSUE DISPENSER GB1 BOBRICK B-5806 X 36 B-5806 X 42 36" AND 42" GRAB BARS GB2 BOBRICK B-5806 X 18 18" VERTICAL GRAB BAR GB3 BOBRICK B-6861 GRAB BAR FOR SHOWER STALL M1 BOBRICK B-165 MIRROR 2'-0" X 4'-0" TD1 BOBRICK B-3944 TOWEL DISPENSER / WASTE RECEPTACLE SD1 BOBRICK B-2112 SOAP DISPENSER ND1 BOBRICK B-353 B-270 B-353: SANITARY NAPKIN DISPOSAL UNIT AT GWB LOCATIONS. B-270: SURFACE, MOUNT SANITARY NAPKIN DISPOSAL UNIT AT PARTITIONS TP1 GENERAL PARTITION TOILET PARTITION AND/OR URINAL SCREEN POWDER COATED URINAL SCREEN BOTTOM 12" FROM FLOOR AND TOP 60" MAX FROM FLOOR N 1 CASEWORK ELEVATION SCALE: 1/2" = 1'-0" 3 CASEWORK DETAIL SCALE: 1/2" = 1'-0" 03/31/22