Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A601
TYPE FSEE DOOR SCHEDULESEE DOOR SCHEDULE TYPE FGSEE DOOR SCHEDULESEE DOOR SCHEDULE 12"APPLIED TRIM, COORDINATE WITH TENANT DOOR HEIGHTDOOR WIDTH TYPE F1 ALIGN WITH EXISTING OPENING 12'-0" +/- MATCH EXIST7'-0" D CC D SF212'-0" +/- MATCH EXISTD C C D SF1 C 6'-9" DOOR AND FINISH SCHEDULE A601 PERMIT SET 11.23.21 PROJECT NUMBER: 210279 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. © COPYRIGHT 2021, CURRAN ARCHITECTURE PROJECT INFORMATION CERTIFICATION ISSUE DATES F :: 317 . 288 . 0753 O :: 317 . 288 . 0681 INDIANAPOLIS, IN 46216 5719 LAWTON LOOP E. DR. #212 THE WEDDING STUDIO AT CLAY TERRACE 14550 CLAY TERRACE BLVDCARMEL, IN 46032 HARDWARE SET #01 3 HINGES 1 PASSAGE SET 3 MUTES 1 WALL STOP HARDWARE SET #03 3 HINGES 1 PUSH PULL 1 CLOSER 1 PERIMETER SEAL 1 FLOOR STOP DOOR HARDWARE DOOR TYPES NOT TO SCALE DOOR FRAME TYPES NOT TO SCALE A. SECTION OF GLAZING REQUIRED TO BE 1" INSULATED GREY TINTED GLASS. B. SECTION OF GLAZING REQUIRED TO BE 1" INSULATED TEMPERED GLASS. C. SECTION OF GLAZING REQUIRED TO BE 1/4" GLASS. D. SECTION OF GLAZING REQUIRED TO BE 1/4" TEMPERED GLASS. E. SECTION OF GLAZING REQUIRED TO BE 1" INSULATED TEMPERED GREY TINTED SPANDREL GLASS. EXTERIOR GLAZING MUST MEET THE FOLLOWING SPECIFICATIONS FOR ENERGY CODE COMPLIANCE: LOW "E" COATING "U" VALUE - MINIMUM OF 0.28 "SHGC" VALUE - MAXIMUM OF 0.47 ROOM FINISH SCHEDULE ROOM # ROOM NAME FLOORING BASE NORTH WALL EAST WALL SOUTH WALL WEST WALL CABINETS / COUNTERTOPS CEILING MAT / HEIGHT REMARKS 100 VESTIBULE WALK OFF CARPET B-1 TBD GLASS GLASS GLASS --GYP BOARD / 12'-0" +/- 101 RECEPTION EXIST B-1 TBD TBD TBD TBD PL-1 EXISTING 102 OFFICE EXIST B-1 TBD TBD TBD TBD PL-1 EXISTING 103 RETAIL SPACE EXIST B-1 TBD TBD TBD TBD —EXISTING 104 FAMILY ROOM EXIST B-1 TBD TBD TBD TBD —EXISTING 105 DRESSING ROOM EXIST B-1 TBD TBD TBD TBD —EXISTING 106 DRESSING ROOM EXIST B-1 TBD TBD TBD TBD —EXISTING 107 FAMILY ROOM EXIST B-1 TBD TBD TBD TBD —EXISTING 108 FAMILY ROOM EXIST B-1 TBD TBD TBD TBD —EXISTING 109 DRESSING ROOM EXIST B-1 TBD TBD TBD TBD —EXISTING 110 DRESSING ROOM EXIST B-1 TBD TBD TBD TBD —EXISTING 111 FAMILY ROOM EXIST B-1 TBD TBD TBD TBD —EXISTING 112 FAMILY ROOM T-1 B-1 TBD TBD TBD TBD —EXISTING 113 DRESSING ROOM T-1 B-1 TBD TBD TBD TBD —EXISTING 114 FAMILY ROOM EXIST B-1 TBD TBD TBD TBD —EXISTING 115 DRESSING ROOM EXIST B-1 TBD TBD TBD TBD —EXISTING 116 CHAMPAGNE BAR EXIST B-1 TBD TBD TBD TBD PL-1 / SS-1 EXISTING 117 CORRIDOR EXIST B-1 TBD TBD TBD TBD — EXISTING 118 RESTROOM T-2 T-3 T-3 / PAINT T-3 / PAINT T-3 / PAINT T-3 / PAINT — ACT-1 / 8'-0" T-1 UP TO 5'-0" 119 RESTROOM T-2 T-3 T-3 / PAINT T-3 / PAINT T-3 / PAINT T-3 / PAINT — ACT-1 / 8'-0" T-1 UP TO 5'-0" 120 STORAGE EXIST B-1 TBD TBD TBD TBD — EXISTING MATERIALS SCHEDULE MARK MATERIAL MANUFACTURER COLOR PATTERN / TEXTURE NUMBER REMARKS T-1 TILE TBD TBD TBD TBD MATCH EXISTING TILE T-2 TILE TBD TBD TBD TBD HERRINGBONE SELECTED BY TENANT T-3 TILE TBD P-1 PAINT TBD P-2 PAINT TBD P-3 PAINT TBD B-1 WALL BASE TBD 6" TALL WOOD BASE PL-1 PLASTIC LAMINATE TBD ACT-1 ACOUSTICAL CEILING TILE TBD SS-1 SOLID SURFACE TBD DOOR SCHEDULE MARK DOOR SIZE MATERIAL GLAZING FINISH RATING FRAME MATERIAL FINISH RATING HARDWARE REMARKS 100 FG 3'-0" X 7'-0"ALUM D MATCH EXIST -- SF1 ALUM MATCH EXIST --03 105 F 3'-0" X 7'-0"SCWD —PAINT —F1 KNOCKDOWN PAINT —02 106 F 3'-0" X 7'-0"SCWD —PAINT —F1 KNOCKDOWN PAINT —02 109 F 3'-0" X 7'-0"SCWD —PAINT —F1 KNOCKDOWN PAINT —02 110 F 3'-0" X 7'-0"SCWD —PAINT —F1 KNOCKDOWN PAINT —02 113 F 3'-0" X 7'-0"SCWD —PAINT —F1 KNOCKDOWN PAINT —02 115 F 3'-0" X 7'-0"SCWD —PAINT —F1 KNOCKDOWN PAINT —02 116 F 3'-0" X 7'-0"SCWD —PAINT —F1 KNOCKDOWN PAINT —01 118 F 3'-0" X 7'-0"SCWD —PAINT —F1 KNOCKDOWN PAINT —02 119 F 3'-0" X 7'-0"SCWD —PAINT —F1 KNOCKDOWN PAINT —02 A. ALL PRE-FINISHED WOOD DOORS SHALL BE SOLID CORE WITH WOOD VENEER, MARSHFIELD OR EQUIVALENT. PROVIDE FINISH SAMPLE AND DOOR CONSTRUCTION DIAGRAM FOR APPROVAL AND HARDWARE BLOCKING COORDINATION. VENEER TO BE WHITE BIRCH OR MAPLE, FREE OF DARK GRAINS UNLESS OTHERWISE NOTED. B. WOOD DOORS SHALL ONLY BE INSTALLED IN CONDITIONED SPACE. C. ALL HARDWARE TO BE MINIMUM 6 PIN BEST COMPATIBLE SYSTEM. COORDINATE KEYING WITH OWNER. D. TEMPERED AND ANNEALED GLASS TO BE CLEANED PER MANUFACTURER REQUIREMENTS. NYLON CLOTH METHODS PREFERRED. DO NOT USE RAZOR BLADES ON GLASS. E. GLASS AROUND DOORS AND IN DOORS SHALL BE TEMPERED UNLESS OTHERWISE NOTED IN ELEVATIONS. F. ANY RATED DOORS TO HAVE LABEL INSTALLED IN JAMB. G. ALL EXITS DOORS TO HAVE TACTILE EXIT SIGNAGE PER 703.4 OF THE ANSI 117.1 2009. H. INSTALL OWNER PROVIDED ADA COMPLIANT RESTROOM SIGNAGE, VERIFY WITH ARCHITECT. GENERAL DOOR AND GLAZING NOTES A. PROCEEDING WITH THE INSTALLATION OF FINISHES WILL BE CONSTRUED THAT THE INSTALLER AND/OR FINISHER HAS INSPECTED AND ACCEPTED THE SUBSTRATE FOR RECEIVING THE WORK. NO CHANGE ORDER WILL BE ISSUED TO RECTIFY CONCEALED, UNKNOWN CONDITIONS OR UNSATISFACTORY SUBSTRATE ONCE THE FINISH WORK HAS PROCEEDED. B. USE MANUFACTURER'S RECOMMENDED INSTALLATION METHODS AND MATERIALS FOR ALL FINISHES. C. CONTRACTOR TO NOTIFY ARCHITECT IMMEDIATELY IF A SPECIFIED FINISH ITEM BECOMES UNAVAILABLE. D. CONTRACTOR TO SUBMIT SHOP DRAWINGS, FLOORING TRANSITION/GRAPHIC LOCATIONS AND SUBMITTALS OF ALL INTERIOR ITEMS AND FINISH MATERIALS TO ARCHITECT REVIEW PRIOR TO PLACING ANY MATERIAL ORDERS. CONTRACTOR MUST ACCOUNT FOR SUBMITTAL REVIEW, ORDERING AND DELIVERY WHEN SCHEDULING PRODUCT INSTALLATION. E. USE SUBFLOOR REDUCER STRIPS (UNDER FLOORING) TO LEVEL MATERIALS OF UNEQUAL HEIGHTS. F. PROVIDE JOHNSONITE SLIM-LINE TRANSITION STRIPS WHERE FLOORING MATERIALS OF UNEQUAL THICKNESS MEET. TRANSITION STRIPS AT DOORS TO BE LOCATED UNDER THE CENTERLINE OF THE DOOR IN CLOSED POSITION. COLOR OF TRANSITION STRIPS TO BE SELECTED BY ARCHITECT. G. ALL WALL TILE TO BE INSTALLED TO FLOOR WITH NO BASE UNLESS NOTED OTHERWISE. H. ANY GRILLES, FIRE EXTINGUISHER CABINETS, ETC., TO BE PAINTED TO MATCH WALL COLOR ON WHICH THEY OCCUR. I. PROVIDE OWNER WITH A MINIMUM OF ONE FULL BOX OR 2% OF EACH FINISH PRODUCT/MATERIAL SPECIFIED ON THE PROJECT. J. ALL WOODWORK/MILLWORK SHALL CONFORM TO THE QUALITY STANDARDS OF ARCHITECTURAL WOODWORK INSTITUTE (AWI) PREMIUM GRADE. FABRICATOR SHALL BE FAMILIAR WITH AWI STANDARDS. K. FABRICATE WOODWORK/MILLWORK ITEMS TO ACTUAL FIELD DIMENSIONS. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, SAMPLES, AND/OR MATERIAL LITERATURE FOR ALL ITEMS. SHOP DRAWINGS SHALL SHOW SUFFICIENT DETAIL TO DETERMINE COMPLIANCE WITH THE QUALITY STANDARDS AND DESIGN INTENT. L. PROVIDE ALL NECESSARY FURRING AND GROUNDS FOR WOODWORK AND FINISH ITEMS. COORDINATE LOCATION OF BLOCKING WITHIN WALLS FOR ITEMS TO BE SECURED TO SURFACE. ALL FASTENERS SHALL BE CONCEALED. M. FINISH ALL SIDES AND BACK OF MILLWORK/CASEWORK. N. ALL COUNTERTOPS TO BE 1 12" THICK WITH A SQUARE EDGE, UNLESS OTHERWISE NOTED. PROVIDE COUNTER SUPPORTS AS REQUIRED. O. PROVIDE GROMMETS IN COUNTERTOPS ABOVE RECEPTACLES. COLOR TO MATCH COUNTER SURFACE. COORDINATE WITH OWNER AND ARCHITECT ON FINAL LOCATION AND SIZE OF GROMMETS BEFORE INSTALLATION. P. REFER TO FINISH SCHEDULE, INTERIOR ELEVATIONS AND SPECIFICATIONS FOR ALL MATERIAL INFORMATION AND LOCATIONS. GENERAL FINISH NOTES GLAZING TYPES HARDWARE SET #02 3 HINGES 1 PRIVACY LOCK SET 1 DOOR STOP 1 CLOSER 3 MUTES STOREFRONT ELEVATIONS NOT TO SCALE 03/31/22