Loading...
HomeMy WebLinkAboutMP101100 CFM 100 CFM 100 CFM 100 CFM 100 CFM 100 CFM 100 CFM 100 CFM 150 CFM 150 CFM 150 CFM 150 CFM 250 CFM 100 CFM 250 CFM 400 CFM 400 CFM 400 CFM 400 CFM 280 CFM 280 CFM 300 CFM 300 CFM 300 CFM 300 CFM 300 CFM 300 CFM 300 CFM 300 CFM 300 CFM 300 CFM 300 CFM NOTE: REWORK/REPAIR CONDENSATE DRAIN PIPING ON AHU-1 & AHU-2. DISCHARGE TO OPEN SITE DRAIN ABOVE RESTROOMS. "OSD" BY OTHERS. NEW 6"Ø BRANCH LINE NEW 6" DIFFUSER & BRANCH LINE (EX) EF-1 AHU-1 EF-2 14" Ø 12"Ø 8"Ø 6"Ø . 10" Ø "ETR" 14" Ø 28"X16"(ETR)24"X14" (ETR) 10"Ø 8"Ø 6"Ø S 30"X16" (ETR) 10"Ø 10"Ø 24"X12"(ETR) 20" DIA. SPIRAL (ETR) 24"X12"(ETR) 12" DIA. SPIRAL (ETR) 10"Ø 10"Ø 10"Ø 16"X14"(ETR) 16" DIA. (ETR) 16" DIA. SPIRAL 14" DIA. SPIRAL ETR) OUTSIDE AIR DUCT FROM ROOF (ETR) 6" Ø 33.3 KW ELEC. HEAT PACKAGE 480VOLT. 3Ø(EX) AHU-2 OUTSIDE AIR DUCT FROM ROOF (ETR) ADJUST TO 400CFM OF OUTSIDE AIR TYP. OF BOTH AHU-1 & 2 NEW DIFFUSER 6" ROUND CONNECT TO EXIST. 14" Ø DUCT AT THIS POINT 10" Ø 10" Ø DISCONNECT AND REMOVE ALL DUCT AND AIR DEVISES IN THIS AREA. PROVIDE NEW DUCT AND AIR DEVISES AS INDICATED. 10" ROUND DIFFUSER PRICE "RCDE" 8" EXH VENT THROUGH ROOF WITH DISCHARGE CAP 32"X18" (ETR) ETR "ETR" 10" TO AHU-2 "ETR" 6" ROUND DIFFUSER (TYP.2) PRICE "RCDE" WHITE STEEL (ETR)(ETR) ROUND SURF. MOUNT DIFFUSER (TYP.) (ETR) (ETR) (ETR) 24 VOLT PLENUM RATED CONTROL WIRING T AHU-2 NEW PROGRAMMABLE THERMOSTAT. VISIONPRO "8000" SERIES ETR CU-1 ROOF LENNOX 10 TON AC UNIT ON ROOF.480VOLT 24"X24" S/A DIFFUSER. (TYP.) EXISTING TO REMAIN IN DRYWALL CEILING 10" Ø 10" Ø RELOCATED DIFFUSER REVISE BRANCHLINE REVISED BRANCHLINE RELOCATED DIFFUSER RELOCATED DIFFUSER NEW BRANCHLINE CAP EXISTING DUCT ETR CU-2 (ROOF) LENNOX 10 TON AC UNIT ON ROOF. 480VOLT 3 PHASE REVISED BRANCHLINE TO 6" Ø NEW 6"Ø DIFFUSER REVISED BRANCHLINE TO 6" Ø NEW 6"Ø DIFFUSER RELOCATED DIFFUSER REVISED BRANCHLINE RELOCATED DIFFUSER 10" NEW BRANCHLINE CAP EXISTING DUCT 8"Ø (ETR) T AHU-1 NEW PROGRAMMABLE THERMOSTAT. 24 VOLT PLENUM RATED CONTROL WIRING TO AHU-1 CAP EXISTING DUCT NEW DIFFUSER AND BRANCHLINE CONNECTED TO EXISTING DUCT 8"Ø 8"Ø (ETR) RELOCATED DIFFUSER REVISED BRANCHLINE 10" "ETR" 8"Ø (ETR) 10" NEW 6"Ø SUPPLY MODIFY BRANCHLINE AND DIFFUSER AS REQUESTED (TYP.4) CONNECT TO EXISTING SPIRAL NEW DIFFUSER WITH PLASTIC FRAME EQUIPMENT SCHEDULE (EXISTING TO REMAIN) AHU-1/AHU-2 LENNOX TAA120 S4D-AG (EXISTING) 2 HP BLOWFIRE MOTOR-BELT DRIVE 12,000 BTUH COOLING COIL (EVAP) 4000CFM NOMINAL CAPACITY EQUIPPED WITH T3EH0035LMIG 33.3KW ELECTRIC HEAT PACKAGE 480 VOLT 3 PHASE CU-1/CU-2 LENNOX 120,000BTUH COOLING (EXISTING)OUTDOOR AC CONDENSING UNIT ROOF MOUNTED 480 VOLT 3 PHASE THERMOSTAT HONEYWELL VISONPRO "8000" SERIES TH8321R101 7DAYPROGRAMMABLE MULTI STAGE TOUCH SCREEN 34" 34"34" 34" 34"3 4 "34 " 34" WC WCMOP SINK LAV BRSINK 12 "12 " CONNECT TO BUILDING WATER BRADFORD WHITE 6GAL ELECT WATERHEATER LOCATEDABOVE CEILING 3 4"34 " CONNECT TO BUILDING SEWER FCD 4" 4" 4" 4" 4" 2" 2" 2" 2" 2" 2" LAV LAV BR SINK WC WC FCO 3" 3" 3" MOP SINK 1HVAC PLAN SCALE: 3/16" = 1'-0" KEY PLAN PERMIT SET 11.23.21 PROJECT NUMBER: 210279 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. © COPYRIGHT 2021, CURRAN ARCHITECTURE PROJECT INFORMATION CERTIFICATION ISSUE DATES F :: 317 . 288 . 0753 O :: 317 . 288 . 0681 INDIANAPOLIS, IN 46216 5719 LAWTON LOOP E. DR. #212 THE WEDDING STUDIO AT CLAY TERRACE 14550 CLAY TERRACE BLVDCARMEL, IN 46032 N CLAY TERRACE BLVDHVAC PLAN MP101 N 2SUPPLY ISOMETRIC NOT TO SCALE 2WASTE ISOMETRIC NOT TO SCALE 03/31/22