Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
R1_rpr_drwg-043385.pdf
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by KA Components. January 24,2022 Fox, Steve Pages or sheets covered by this seal: I49787967 thru I49787967 My license renewal date for the state of Indiana is July 31, 2022. 043385 ROOF TRUSSES IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 8 12 3x4 = = 1.5x4 3x4 = = 4x5 3x5 = 3x4 = = 1.5x4 3x4 = 1 7 12 19 11 10 9 20 8 2 6 3 5 21 22 4 1-0-0 -1-0-0 1-0-0 24-6-0 5-8-1 11-9-0 5-8-1 17-5-1 6-0-15 6-0-15 6-0-15 23-6-0 7-6-12 15-6-6 7-11-10 23-6-0 7-11-10 7-11-10 8-10-3 0-4-7 8-2-7 Scale = 1:56.7 Plate Offsets (X, Y): [2:0-0-7,Edge] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.41 Vert(LL) 0.04 9-18 >999 240 MT20 244/190 Snow (Ps/Pg) 9.3/20.0 Lumber DOL 1.15 BC 0.69 Vert(CT) -0.13 9-18 >999 180 TCDL 10.0 Rep Stress Incr NO WB 0.23 Horz(CT) 0.04 6 n/a n/a BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS BCDL 10.0 Weight: 189 lb FT = 16% LUMBER TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.2 or 2x4 SPF No.2 *Except* 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. 6) Dead + 0.6 C-C Wind (Pos. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=40, 2-4=20, 4-22=27, 6-22=20, 6-7=14, 13-16=-52 (F=-40) Horz: 1-2=-52, 2-4=-32, 4-22=39, 6-22=32, 6-7=26 7) Dead + 0.6 C-C Wind (Pos. Internal) Case 2: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=14, 2-21=20, 4-21=27, 4-6=20, 6-7=40, 13-16=-52 (F=-40) Horz: 1-2=-26, 2-21=-32, 4-21=-39, 4-6=32, 6-7=52 8) Dead + 0.6 C-C Wind (Neg. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=-4, 2-4=-42, 4-6=-42, 6-7=-36, 13-16=-60 (F=-40) Horz: 1-2=-16, 2-4=22, 4-6=-22, 6-7=-16 9) Dead + 0.6 C-C Wind (Neg. Internal) Case 2: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=-36, 2-4=-42, 4-6=-42, 6-7=-4, 13-16=-60 (F=-40) Horz: 1-2=16, 2-4=22, 4-6=-22, 6-7=16 10) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=16, 2-4=0, 4-6=11, 6-7=5, 13-16=-52 (F=-40) Horz: 1-2=-28, 2-4=-12, 4-6=23, 6-7=17 11) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=5, 2-4=11, 4-6=0, 6-7=16, 13-16=-52 (F=-40) Horz: 1-2=-17, 2-4=-23, 4-6=12, 6-7=28 12) Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=-26, 2-4=-31, 4-6=-9, 6-7=-3, 13-16=-60 (F=-40) Horz: 1-2=6, 2-4=11, 4-6=11, 6-7=17 13) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=-3, 2-4=-9, 4-6=-31, 6-7=-26, 13-16=-60 (F=-40) Horz: 1-2=-17, 2-4=-11, 4-6=-11, 6-7=-6 14) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) PRODUCT CODE APPROVALS LATERAL BRACING LOCATION Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. The first dimension is the plate width measured perpendicular to slots. Second dimension is the length parallel to slots. Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. 21.The design does not take into account any dynamic or other loads other than those expressly stated. Failure to Follow Could Cause Property Damage or Personal Injury (Drawings not to scale) © 2012 MiTek® All Rights Reserved MiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020 edge of truss. / 16 " from outside 1 0 - ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. W4-6 W3-6 W3-7 W2-7 W1-7 C1-8 C7-8 C6-7 C5-6 C4-5 C3-4 C1-2 C2-3 TOP CHORD TOP CHORD 8 7 6 5 4 1 2 3 BOTTOM CHORDS TOP CHORDS BEARING 4 x 4 PLATE SIZE This symbol indicates the required direction of slots in connector plates. / 16 " 1 For 4 x 2 orientation, locate plates 0- 1 " / 4 3 PLATE LOCATION AND ORIENTATION Symbols Numbering System General Safety Notes * Plate location details available in MiTek 20/20 software or upon request. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 6-4-8 WEBS Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. dimensions shown in ft-in-sixteenths Vert: 1-2=46, 2-4=30, 4-6=30, 6-7=46, 13-16=-52 (F=-40) Horz: 1-2=-58, 2-4=-42, 4-6=42, 6-7=58 15) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=30, 2-4=13, 4-6=13, 6-7=30, 13-16=-52 (F=-40) Horz: 1-2=-42, 2-4=-25, 4-6=25, 6-7=42 16) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=-15, 2-4=-21, 4-6=-21, 6-7=-15, 13-16=-60 (F=-40) Horz: 1-2=-5, 2-4=1, 4-6=-1, 6-7=5 17) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=-15, 2-4=-21, 4-6=-21, 6-7=-15, 13-16=-60 (F=-40) Horz: 1-2=-5, 2-4=1, 4-6=-1, 6-7=5 18) Dead + Snow on Overhangs: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-2=-39, 2-4=-20, 4-6=-20, 6-7=-39, 13-16=-60 (F=-40) 19) Dead: Lumber Increase=0.90, Plate Increase=0.90 Plt. metal=0.90 Uniform Loads (lb/ft) Vert: 1-4=-20, 4-7=-20, 13-16=-60 (F=-40) 20) Dead + 0.75 Snow (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=-38, 2-4=-43, 4-6=-26, 6-7=-21, 13-16=-60 (F=-40) Horz: 1-2=4, 2-4=9, 4-6=8, 6-7=12 21) Dead + 0.75 Snow (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=-21, 2-4=-26, 4-6=-43, 6-7=-38, 13-16=-60 (F=-40) Horz: 1-2=-12, 2-4=-8, 4-6=-9, 6-7=-4 22) Dead + 0.75 Snow (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=-30, 2-4=-35, 4-6=-35, 6-7=-30, 13-16=-60 (F=-40) Horz: 1-2=-4, 2-4=1, 4-6=-1, 6-7=4 23) Dead + 0.75 Snow (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=-30, 2-4=-35, 4-6=-35, 6-7=-30, 13-16=-60 (F=-40) Horz: 1-2=-4, 2-4=1, 4-6=-1, 6-7=4 24) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=-54, 2-4=-59, 4-6=-42, 6-7=-38, 13-16=-60 (F=-40) Horz: 1-2=4, 2-4=9, 4-6=8, 6-7=12 25) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=-38, 2-4=-42, 4-6=-59, 6-7=-54, 13-16=-60 (F=-40) Horz: 1-2=-12, 2-4=-8, 4-6=-9, 6-7=-4 26) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=-46, 2-4=-51, 4-6=-51, 6-7=-46, 13-16=-60 (F=-40) Horz: 1-2=-4, 2-4=1, 4-6=-1, 6-7=4 27) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=-46, 2-4=-51, 4-6=-51, 6-7=-46, 13-16=-60 (F=-40) Horz: 1-2=-4, 2-4=1, 4-6=-1, 6-7=4 28) Dead + 0.6 C-C Wind Min. Down: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-2=4, 2-4=-28, 4-7=-28, 13-16=-52 (F=-40) Horz: 1-2=-16, 2-4=16, 4-7=-16 29) Dead + 0.6 C-C Wind Min. Upward: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (lb/ft) Vert: 1-4=4, 4-7=4, 13-16=-52 (F=-40) Horz: 1-4=-16, 4-7=16 30) 1st Dead + Roof Live (unbalanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-4=-60, 4-7=-20, 13-16=-60 (F=-40) 31) 2nd Dead + Roof Live (unbalanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-4=-20, 4-7=-60, 13-16=-60 (F=-40) 32) 3rd Dead + 0.75 Roof Live (unbalanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-4=-50, 4-7=-20, 13-16=-60 (F=-40) 33) 4th Dead + 0.75 Roof Live (unbalanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-4=-20, 4-7=-50, 13-16=-60 (F=-40) Job Truss Truss Type Qty Ply ROOF TRUSSES I49787967 043385 R1 Common 11 1 Job Reference (optional) KA Components, Otterbein, IN - 47970, Run: 8.43 E Apr 29 2021 Print: 8.430 E Apr 29 2021 MiTek Industries, Inc. Mon Jan 24 12:14:33 Page: 2 ID:Kq_k?EQdmluE_ZI6YZnb1UyB0XY-oYun8mD57MkU_E4qDyZM30bZ7HCVyANY7A39OJzs8nq 9-5,11-3:2x4 SPF Stud LBR SCAB 12-8 SPF No.2 one side BRACING TOP CHORD Structural wood sheathing directly applied or 4-0-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 2=1198/0-3-8, 6=1198/0-3-8 Max Horiz 2=-189 (LC 12) Max Grav 2=1470 (LC 2), 6=1470 (LC 2) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1971/0, 3-21=-1850/0, 4-21=-1742/0, 4-22=-1743/0, 5-22=-1850/0, 5-6=-1972/0 BOT CHORD 2-12=0/1601, 12-19=0/1601, 11-19=0/1601, 10-11=0/1058, 9-10=0/1058, 9-20=0/1596, 8-20=0/1596, 6-8=0/1596 WEBS 4-9=0/933, 5-9=-353/243, 4-11=0/932, 3-11=-354/243 NOTES 1) N/A 2) Unbalanced roof live loads have been considered for this design. 3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=24ft; L=24ft; eave=4ft; Cat. II; Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior (1) 2-0-0 to 11-9-0, Exterior(2R) 11-9-0 to 14-9-0, Interior (1) 14-9-0 to 24-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Ps=9.3 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=0.61; Ct=1.10; Unobstructed slippery surface 5) Roof design snow load has been reduced to account for slope. 6) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7) The Fabrication Tolerance at joint 9 = 3%, joint 11 = 3% 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Load case(s) 1 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-4=-39, 4-7=-39, 13-16=-60 (F=-40) 2) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-4=-60, 4-7=-60, 13-16=-60 (F=-40) 3) Dead + 0.75 Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-4=-50, 4-7=-50, 13-16=-60 (F=-40) 4) Dead + 0.75 Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-4=-34, 4-7=-34, 13-16=-60 (F=-40) 5) Dead + Uninhabitable Attic Without Storage: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (lb/ft) Vert: 1-4=-20, 4-7=-20, 13-16=-80 (F=-40) Job Truss Truss Type Qty Ply ROOF TRUSSES I49787967 043385 R1 Common 11 1 Job Reference (optional) KA Components, Otterbein, IN - 47970, Run: 8.43 E Apr 29 2021 Print: 8.430 E Apr 29 2021 MiTek Industries, Inc. Mon Jan 24 12:14:33 Page: 1 ID:Kq_k?EQdmluE_ZI6YZnb1UyB0XY-oYun8mD57MkU_E4qDyZM30bZ7HCVyANY7A39OJzs8nq Continued on page 2 1.0 UNITS DS 1 OF 1 REPAIR: ADD 40 PLF TO BOTTOM CHORD. APPLY 2 X 12 X 20' SPF/DF/SP NO.2 SCAB TO ONE FACE OF TRUSS CENTERED SPLICE. ATTACH WITH (0.131" X 3") NAILS PER THE FOLLOWING NAIL SCHEDULE: 2 ROWS: SPACED @ 6" O.C. USE 2" MEMBER END DISTANCE. 1-4-0 1-4-0 ATTACH 1/2" PLYWOOD OR OSB GUSSET (15/32" RATED SHEATHING 32/16 EXP 1) TO EACH FACE OF TRUSS WITH (0.131" X 2.5" MIN.) NAILS PER THE FOLLOWING NAIL SCHEDULE: 3 ROWS: SPACED @ 4" O.C. NAILS TO BE DRIVEN FROM BOTH FACES. STAGGER SPACING FROM FRONT TO BACK FACE FOR A NET 2" O.C. SPACING IN EACH COVERED TRUSS MEMBER. USE 2" MEMBER END DISTANCE. January 24,2022