Loading...
HomeMy WebLinkAboutWaverley A LAYOUTGE01 T01 T01 T01 T01 T01 T01 T01 T01 T01 GE02GE03GE04 TG01 GE05 T02 T02 T02TG02 GE06T03T04T04T04T04T04T06T06T04T04T04T04T04T04T04T04GE07GE08 T07 T08 T08 T08 T09 T10 T10 T10 T10 T10 T10 TG03T11T11T11T11T11T12T12T12T12T13M01GE09M02M02M02M02M02M02M02M02T14T15T15T15T15T15T15T16 M03M03M04M04M04M04M04M04V01 V02 V03 V04 V05 V06 V07 V08 V09 V10 V11 V12 V14V15V16V17 V18 V19 V20V21V22GE10V23V24V25V26V27V28V29V30PBE01PB01PB02PB02PB02PB02PB02PB02PB02PB02PB02PB03PB04PB04PB04PB04PB04PB04PB04PB05PBE02 PB06 PB06 PB06 PB06 PB06 PB06 PB06 PB06 PB06 PB06 PB06 PB06PBE03PB04PB04PB04PB04PB04PB04PB04PB04SFBO1SFBO2SFBO3 SFBO4SFBO5SFBO6SFBO7SFBO8SFBO9 SFBO10SFBO112-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-0010-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-00 2-00-00 2-00-00 1-00-00 1-09-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 1-09-00 2-00-00 2-00-00 2-00-00 2-00-001-02-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-00 2-00-00 2-00-00 2-01-08 2-02-08 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-04-0015-08-00 17-04-00 21-00-00 54-00-007-00-006-00-00 11-07-08 68-00-0038-00-0016-00-00 54-00-00 10-00-0012-00-0016-00-00 2-00-0066-08-003-04-0070-00-0070-00-002-00-00HANGER SCHEDULESYM QTY DESCRIPTION SYM QTY DESCRIPTIONA H2.5A A - LTHJRB - HGUS26-2 B - LUS24C - HGUS26-2-2 C - LUS26-2D - HGUS28-2 D - LUS410E HTU26 E - MUS26F - LTHUL F - THA422-2LENNARWAVERLEY A - WAVERLEY AAddress:Salesperson:Scale:Job Number: B21103283 Drawn by:Katherine SelvaDate: 03/10/2022 Lot Number: - Designed by:Katherine Selva TRUSS PLACEMENT GUIDE NOTES: DO NOT CUT OR MODIFY TRUSSES. TRUSSES ARE SPACED 24" ON CENTER UNLESS NOTED OTHERWISE. REFER TO THE INDIVIDUAL TRUSS DESIGN DRAWINGS FOR THE LOCATION OF LATERAL BRACING AND MULTY-PLY CONNECTION REQUIREMENTS. PER ANSI TPI 1-2002 THE TRUSS ENGINEER IS RESPONSIBLE FOR TRUSS TO TRUSSCONECTIONS AND TRUSS PLY TO PLY CONNECTIONS. THIS PLACEMENT PLANRECOMMENDS TRUSS TO BEARING CONNECTIONS AND TRUSS TO BEAM CONNECTIONSWHICH SHALL BE REVIEWED BY THE BUILDING DESIGNER TO RESOLVE ALL ROOF FORCESADEQUATELY TO THE FOUNDATION. ALL TRUSS TIES TO BE INSTALLED BEFORE O.S.B. IS APPLIED TO ROOFDO NOT CUT TRUSSES! TRUSSES CUT BY ANY TRADE / SUB-CONTRACTOR WITHOUT FIRST RECEIVING PERMISSION ANDDIRECTION FROMPROBuild, (317) 834 5380, SHALL BE CONTRACTOR / BUILDER RESPONSIBILITY! NO EXCEPTIONS 3D VIEW 1 3D VIEW 2 CUSTOMER:JOB NAME & MODEL: