Loading...
HomeMy WebLinkAboutWaverley A TRS16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). March 11,2022 Garcia, Juan Pages or sheets covered by this seal: I50726092 thru I50726161 My license renewal date for the state of Indiana is July 31, 2022. Waverley_A Waverley A IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss GE01 Truss Type GABLE Qty 1 Ply 1 Waverley A Job Reference (optional) I50726092 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:39:35 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-1Zg9jgD3wS50WZhKhVs9GqHRc47GiwP4tDnATezcB7s Scale = 1:50.5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 28 27 26 25 24 23 22 21 20 19 18 17 16 29 30 3x4 3x4 4x6 3x4 3x4 5x6 8-0-08-0-0 16-0-08-0-0 -0-11-4 0-11-4 8-0-0 8-0-0 16-0-0 8-0-0 16-11-4 0-11-4 1-7-58-3-51-7-56-5-110.00 12 10.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.18 0.09 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 15 15 16 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 68 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 16-0-0. (lb) - Max Horz 28=-161(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 16, 23, 24, 25, 26, 27, 21, 20, 19, 18, 17 except 28=-153(LC 10), 22=-102(LC 11) Max Grav All reactions 250 lb or less at joint(s) 16, 23, 24, 25, 26, 27, 21, 20, 19, 18, 17 except 28=261(LC 18), 22=309(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 6-7=-110/260, 7-8=-132/301, 8-9=-132/301, 9-10=-110/260 WEBS 8-22=-341/118 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -0-11-4 to 2-0-12, Exterior(2N) 2-0-12 to 8-0-0, Corner(3R) 8-0-0 to 11-0-0, Exterior(2N) 11-0-0 to 16-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 23, 24, 25, 26, 27, 21, 20, 19, 18, 17 except (jt=lb) 28=153, 22=102. 11) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 22, 23, 24, 25, 26, 27, 21, 20, 19, 18, 17. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss GE02 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 Waverley A Job Reference (optional) I50726093 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:39:39 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-vLvfZ1Ga_hbR?B?5wLx5QgS3rhTQekcfnqlOcPzcB7o Scale = 1:77.7 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 67 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 272829 30 31 32 33 34 35 3637 7271 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 73 74 3x4 4x6 3x6 3x6 3x4 3x4 3x6 5x6 5x6 5x6 43-6-843-6-8 -0-11-4 0-11-4 18-2-0 18-2-0 38-2-0 20-0-0 43-6-8 5-4-8 1-4-511-11-88-9-1411-11-87.00 12 Plate Offsets (X,Y)-- [2:0-3-0,Edge], [17:0-3-0,0-1-12], [33:0-3-0,0-1-12], [50:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.42 0.20 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.01 (loc) 1 1 38 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 439 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 37-38: 2x4 SPF No.2 OTHERS 2x4 SPF No.2 *Except* 12-63,11-64,10-65,9-66,8-67,7-68,5-69,4-70,3-71: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 17-33. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 37-38, 33-42, 32-43, 31-44, 30-45, 29-46, 27-47, 26-48, 25-49, 24-50, 23-51, 22-52, 21-53, 20-54, 19-55, 18-56, 17-57, 16-58, 15-60, 14-61, 13-62, 34-41, 35-40, 36-39 REACTIONS.All bearings 43-6-8. (lb) - Max Horz 72=288(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 38, 42, 44, 55, 57, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 41, 39 except 72=-285(LC 10), 71=-391(LC 9) Max Grav All reactions 250 lb or less at joint(s) 38, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 41, 40, 39 except 72=491(LC 11), 71=317(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-72=-355/200, 2-3=-403/277, 3-4=-269/196 WEBS 3-71=-188/257 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=44ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -0-11-4 to 3-6-0, Exterior(2N) 3-6-0 to 18-2-0, Corner(3R) 18-2-0 to 22-6-4, Exterior(2N) 22-6-4 to 38-2-0, Corner(3R) 38-2-0 to 42-6-4, Exterior(2N) 42-6-4 to 43-4-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 38, 42, 44, 55, 57, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 41, 39 except (jt=lb) 72=285, 71=391. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss GE03 Truss Type GABLE COMMON Qty 1 Ply 1 Waverley A Job Reference (optional) I50726094 8.430 s Aug 16 2021 MiTek Industries, Inc. Fri Mar 11 15:12:53 2022 Page 1 ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-fjS1pilQUSVBMblwwRl4m5fBcOezc1DNPUgrFFzbyae Scale = 1:72.5 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 64 65 66 67 68 69 70 71 72 73 74 75 5x6 5x6 3x6 3x4 3x8 3x8 3x6 4x6 3x4 3x8 3x4 5x6 3x6 5x6 5x6 9-3-139-3-13 18-2-08-10-4 27-10-09-8-0 37-8-89-10-8 -0-11-4 0-11-4 6-4-6 6-4-6 12-3-3 5-10-13 18-2-0 5-10-13 24-7-6 6-5-5 31-0-11 6-5-5 37-8-8 6-7-13 0-4-510-11-87.00 12 Plate Offsets (X,Y)-- [2:0-8-0,0-0-6], [4:0-2-12,0-3-4], [6:0-4-0,0-2-4], [10:Edge,0-1-8], [12:0-1-8,0-1-8], [13:0-3-0,0-3-0], [15:0-2-8,0-1-8], [43:0-1-14,0-1-0], [46:0-1-14,0-1-0], [55:0-1-14,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.67 0.95 0.91 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.35 -0.55 0.08 (loc) 11-12 11-12 11 l/defl >999 >810 n/a L/d 240 180 n/a PLATES MT20 Weight: 330 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 13-15: 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-16,5-16,5-14: 2x3 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 24-25,12-29,34-35,38-40,41-42: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 2-7-12 oc purlins, except end verticals, and 2-0-0 oc purlins (4-3-1 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 14-16. WEBS 1 Row at midpt 10-11, 5-14, 7-12 2 Rows at 1/3 pts 9-11 REACTIONS. (size)11=Mechanical, 2=0-3-8 Max Horz 2=297(LC 9) Max Grav 11=1795(LC 17), 2=1806(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-64=-2906/0, 3-64=-2853/0, 3-4=-2719/0, 4-5=-2583/8, 5-65=-1916/31, 6-65=-1902/67, 6-66=-1603/78, 66-67=-1602/78, 7-67=-1602/78, 7-68=-1248/72, 8-68=-1248/72, 8-9=-1248/72 BOT CHORD 2-16=-79/2545, 16-70=-86/2105, 70-71=-86/2105, 15-71=-86/2105, 14-15=-86/2105, 14-72=-57/1470, 13-72=-57/1470, 13-73=-57/1470, 12-73=-57/1470, 12-74=-68/940, 74-75=-68/940, 11-75=-68/940 WEBS 3-16=-305/96, 5-16=0/667, 5-14=-725/74, 6-14=0/621, 7-14=-50/350, 7-12=-659/60, 9-12=0/1173, 9-11=-1736/17 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=38ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-11-4 to 2-10-0, Interior(1) 2-10-0 to 18-2-0, Exterior(2R) 18-2-0 to 23-6-0, Interior(1) 23-6-0 to 37-7-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Provide adequate drainage to prevent water ponding. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Refer to girder(s) for truss to truss connections. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. Continued on page 2 March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss GE03 Truss Type GABLE COMMON Qty 1 Ply 1 Waverley A Job Reference (optional) I50726094 8.430 s Aug 16 2021 MiTek Industries, Inc. Fri Mar 11 15:12:53 2022 Page 2 ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-fjS1pilQUSVBMblwwRl4m5fBcOezc1DNPUgrFFzbyae NOTES- 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss GE04 Truss Type Common Supported Gable Qty 1 Ply 1 Waverley A Job Reference (optional) I50726095 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:39:43 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-o69APPJ51v5tUoJs9A?1aWdpEItZaTdFiSjblAzcB7k Scale = 1:51.4 Sheet FrontFull Sheathing1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 22 21 20 19 18 17 16 15 14 3x6 4x6 3x6 11-7-811-7-8 -1-3-4 1-3-4 5-9-12 5-9-12 11-7-8 5-9-12 12-10-12 1-3-4 1-4-118-2-11-4-1114.00 12 Plate Offsets (X,Y)-- [7:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.14 0.06 0.43 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 77 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 11-7-8. (lb) - Max Horz 22=190(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 22, 14, 19, 20, 17, 16, 15 except 21=-103(LC 9) Max Grav All reactions 250 lb or less at joint(s) 22, 14, 18, 19, 20, 21, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 7-18=-297/180 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-3-4 to 1-9-12, Exterior(2N) 1-9-12 to 5-9-12, Corner(3R) 5-9-12 to 8-9-12, Exterior(2N) 8-9-12 to 12-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 22, 14, 19, 20, 17, 16, 15 except (jt=lb) 21=103. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss GE05 Truss Type Common Supported Gable Qty 1 Ply 1 Waverley A Job Reference (optional) I50726096 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:39:44 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-GIjYclKjoDDk5yt3juXG7j9zXiC7I_hOx6S9HczcB7j Scale = 1:66.0 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 28 27 26 25 24 23 22 21 20 19 18 17 16 3x4 3x4 4x6 3x4 3x4 15-8-015-8-0 -1-3-4 1-3-4 7-10-0 7-10-0 15-8-0 7-10-0 16-11-4 1-3-4 1-4-1110-6-51-4-1114.00 12 Plate Offsets (X,Y)-- [8:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.23 0.10 0.19 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 15 15 16 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 118 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 8-22,7-23,9-21: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 8-22, 7-23, 9-21 REACTIONS.All bearings 15-8-0. (lb) - Max Horz 28=235(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 23, 24, 25, 26, 21, 20, 19, 18 except 28=-170(LC 10), 16=-146(LC 11), 27=-137(LC 9), 17=-129(LC 8) Max Grav All reactions 250 lb or less at joint(s) 23, 24, 25, 26, 27, 21, 20, 19, 18, 17 except 28=286(LC 18), 16=268(LC 17), 22=361(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 6-7=-200/272, 7-8=-229/305, 8-9=-229/305, 9-10=-200/272 WEBS 8-22=-404/259 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-3-4 to 1-8-12, Exterior(2N) 1-8-12 to 7-10-0, Corner(3R) 7-10-0 to 10-10-0, Exterior(2N) 10-10-0 to 16-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 24, 25, 26, 21, 20, 19, 18 except (jt=lb) 28=170, 16=146, 27=137, 17=129. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss GE06 Truss Type Roof Special Supported Gable Qty 1 Ply 1 Waverley A Job Reference (optional) I50726097 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:39:46 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-ChqJ1QLzKqTSLF1RqJZkC8EDTWromvIhOQxGLVzcB7h Scale = 1:69.1 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 30 29 28 27 26 25 24 23 22 21 20 19 18 17 31 32 4x6 4x6 3x6 5x6 3x4 19-11-819-11-8 19-11-8 19-11-8 12-0-110-5-07.00 12 Plate Offsets (X,Y)-- [1:0-3-12,Edge], [27:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.59 0.28 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 16 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 146 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 2-29,3-28,4-27,5-26: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 1-30, 2-29, 3-28, 4-27, 5-26 REACTIONS.All bearings 19-11-8. (lb) - Max Horz 30=-319(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16 Max Grav All reactions 250 lb or less at joint(s) 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 6-7=-256/209, 7-8=-284/223, 8-9=-311/237, 9-10=-338/251, 10-11=-365/265, 11-13=-392/279, 13-14=-421/295, 14-15=-442/300, 15-16=-503/346 BOT CHORD 29-30=-292/444, 28-29=-292/444, 27-28=-292/444, 26-27=-291/444, 25-26=-291/444, 24-25=-291/444, 23-24=-291/444, 22-23=-291/444, 21-22=-291/444, 20-21=-291/444, 19-20=-291/444, 18-19=-291/444, 17-18=-291/444, 16-17=-291/444 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) 0-1-12 to 3-1-12, Exterior(2N) 3-1-12 to 19-11-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss GE07 Truss Type Common Supported Gable Qty 1 Ply 1 Waverley A Job Reference (optional) I50726098 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:39:48 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-83y3S6NDsSjAaZBqyjbCHZKcbJYvEpg_skQMQNzcB7f Scale = 1:78.5 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 2122 23 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 3x4 3x4 4x6 3x6 3x6 3x4 6-11-1 3 25- 2 - 1 4 27-10-0 27-10-0 6-0-6 6-0-6 27-10-0 21-9-10 9-7-613-1-100-5-07.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.35 0.18 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 23 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 244 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 *Except* 12-33,13-32,14-31,15-30,16-29,18-28,19-27,20-26,21-25,22-24: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 1-45, 6-40, 5-41, 4-42, 3-43, 2-44, 7-39, 8-38, 9-37, 10-36, 11-34, 12-33 REACTIONS.All bearings 27-10-0. (lb) - Max Horz 45=-310(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 45, 40, 42, 43, 38, 37, 36, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23 except 44=-130(LC 12) Max Grav All reactions 250 lb or less at joint(s) 45, 40, 41, 42, 43, 44, 39, 38, 37, 36, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 19-20=-268/210, 20-21=-292/225, 21-22=-316/238, 22-23=-358/268 BOT CHORD 44-45=-228/312, 43-44=-228/312, 42-43=-228/312, 41-42=-228/312, 40-41=-228/312, 39-40=-228/312, 38-39=-228/312, 37-38=-228/312, 36-37=-228/312, 34-36=-228/312, 33-34=-228/312, 32-33=-228/312, 31-32=-228/312, 30-31=-228/312, 29-30=-228/312, 28-29=-228/312, 27-28=-228/312, 26-27=-228/312, 25-26=-228/312, 24-25=-228/312, 23-24=-228/312 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=28ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) 0-1-12 to 3-4-6, Exterior(2N) 3-4-6 to 6-0-6, Corner(3R) 6-0-6 to 9-0-6 , Exterior(2N) 9-0-6 to 27-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 45, 40, 42, 43, 38, 37, 36, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23 except (jt=lb) 44=130. 10) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 23. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss GE08 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 Waverley A Job Reference (optional) I50726099 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:39:49 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-dGWRfSOsdlr0Cjm0VR6RqnspQjvJzG075OAwyqzcB7e Scale = 1:53.4 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 38 39 3x4 3x4 3x4 3x4 4x6 6x6 6x6 21-0-021-0-0 -1-3-4 1-3-4 6-6-0 6-6-0 14-6-0 8-0-0 21-0-0 6-6-0 22-3-4 1-3-4 1-6-119-1-111-6-119-1-1114.00 12 Plate Offsets (X,Y)-- [7:0-2-11,Edge], [13:0-2-11,Edge], [33:0-3-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.22 0.10 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 19 19 20 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 168 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 13-25,12-26,11-27,10-28,9-29,8-30,7-31: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 7-13. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 13-25, 12-26, 11-27, 10-28, 9-29, 8-30, 7-31 REACTIONS.All bearings 21-0-0. (lb) - Max Horz 37=-210(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 27, 28, 29, 32, 34, 35, 24, 23, 22 except 37=-150(LC 10), 20=-129(LC 9), 36=-137(LC 11), 21=-120(LC 10) Max Grav All reactions 250 lb or less at joint(s) 25, 26, 27, 28, 29, 30, 31, 32, 34, 35, 36, 24, 23, 22, 21 except 37=275(LC 18), 20=255(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 6-7=-211/282, 13-14=-211/282 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-3-4 to 1-8-12, Exterior(2N) 1-8-12 to 6-6-0, Corner(3R) 6-6-0 to 9-6-0, Exterior(2N) 9-6-0 to 14-6-0, Corner(3R) 14-6-0 to 17-6-0, Exterior(2N) 17-6-0 to 22-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 27, 28, 29, 32, 34, 35, 24, 23, 22 except (jt=lb) 37=150, 20=129, 36=137, 21=120. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss GE09 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 Waverley A Job Reference (optional) I50726100 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:39:51 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-ZeeC48P69N6kR1wPds9vvCy8tXadRBQQYif11izcB7c Scale = 1:70.6 Sheet Front Full Sheathing1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 23 22 21 20 19 18 17 16 15 14 13 24 25 3x4 3x4 3x6 3x4 3x4 13-6-813-6-8 1-10-8 1-10-8 13-6-8 11-8-0 10-10-511-11-87.00 12 Plate Offsets (X,Y)-- [3:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.29 0.18 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 13 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 173 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-12. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 1-23, 12-13, 11-14, 10-15, 9-16, 8-17, 7-18 , 6-19, 5-20, 4-21, 2-22 REACTIONS.All bearings 13-6-8. (lb) - Max Horz 23=23(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 23, 15, 16, 17, 18, 19, 20 except 13=-115(LC 12), 22=-139(LC 12) Max Grav All reactions 250 lb or less at joint(s) 23, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) 0-1-12 to 1-10-8, Corner(3R) 1-10-8 to 4-10-8, Exterior(2N) 4-10-8 to 13-4-12 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 15, 16, 17, 18, 19, 20 except (jt=lb) 13=115, 22=139. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss GE10 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726101 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:39:52 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-1rBaIUQkwgEb3AVbBZg8SPUIxww2AaZanMOaZ8zcB7b Scale = 1:51.9 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 25 3x6 3x4 3x4 3x4 15-7-215-7-2 15-7-2 15-7-2 9-1-27.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.33 0.17 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 14 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 89 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-3: 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 13-14 REACTIONS.All bearings 15-7-2. (lb) - Max Horz 1=238(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 14, 1, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24 Max Grav All reactions 250 lb or less at joint(s) 14, 1, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-417/270, 2-4=-379/247, 4-5=-350/235, 5-6=-319/219, 6-7=-288/205, 7-8=-257/190 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) 0-6-8 to 3-7-2, Exterior(2N) 3-7-2 to 15-5-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 1, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss M01 Truss Type Monopitch Qty 1 Ply 1 Waverley A Job Reference (optional) I50726102 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:39:53 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-V1lyVpRMh_MSgK3nkHBN_d1UMKE9v?5j?0875bzcB7a Scale: 3/16"=1' 1 2 4 35 2x4 3x4 2x4 3x4 4-5-84-5-8 4-5-8 4-5-8 9-5-812-0-117.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.29 0.24 0.37 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.05 -0.00 (loc) 3-4 3-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-3: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-3, 1-4 REACTIONS. (size)3=0-3-8, 4=0-3-8 Max Horz 4=55(LC 12) Max Uplift 3=-134(LC 12) Max Grav 3=238(LC 17), 4=227(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 1-3=-146/268 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-4 to 3-1-4, Interior(1) 3-1-4 to 4-3-12 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 3=134. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss M02 Truss Type Piggyback Base Qty 8 Ply 1 Waverley A Job Reference (optional) I50726103 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:39:53 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-V1lyVpRMh_MSgK3nkHBN_d1NaK9Nvz3j?0875bzcB7a Scale = 1:69.0 1 2 3 4 7 6 5 8 9 10 11 12 13 3x6 5x6 3x4 3x8 2x4 3x8 3x8 7-7-47-7-4 13-6-85-11-4 1-10-8 1-10-8 7-7-4 5-8-12 13-6-8 5-11-4 10-10-511-11-87.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [5:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.72 0.54 0.50 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.16 -0.25 -0.00 (loc) 6-7 6-7 5 l/defl >988 >635 n/a L/d 240 180 n/a PLATES MT20 Weight: 111 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5, 3-6, 4-6, 1-7, 2-7 REACTIONS. (size)5=Mechanical, 7=0-3-8 Max Horz 7=298(LC 9) Max Uplift 5=-167(LC 9), 7=-116(LC 8) Max Grav 5=722(LC 17), 7=716(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-618/229 BOT CHORD 6-7=-302/343 WEBS 2-6=-166/410, 3-6=-407/138, 4-6=-240/563, 2-7=-586/332 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-12 to 1-10-8, Exterior(2R) 1-10-8 to 6-1-7, Interior(1) 6-1-7 to 13-4-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 5=167, 7=116. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss M03 Truss Type Monopitch Qty 2 Ply 1 Waverley A Job Reference (optional) I50726104 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:39:54 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-zDJKi9S_SIUJIUe_I_icXqacnkYleX6tEgthe1zcB7Z Scale = 1:15.4 1 2 3 4 2x4 2x4 2x4 5-11-85-11-8 -0-11-4 0-11-4 5-11-8 5-11-8 0-4-02-3-134.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.50 0.34 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.06 -0.12 0.00 (loc) 2-4 2-4 4 l/defl >999 >550 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=0-3-8, 2=0-3-8 Max Horz 2=57(LC 9) Max Uplift 2=-21(LC 12) Max Grav 4=220(LC 1), 2=298(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-11-4 to 2-0-12, Interior(1) 2-0-12 to 5-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss M04 Truss Type Monopitch Qty 6 Ply 1 Waverley A Job Reference (optional) I50726105 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:39:55 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-RQtiwVScCbcAweDAsiDr326sd8xFN_M0TKdEATzcB7Y Scale = 1:11.0 1 2 3 4 2x4 2x4 2x4 3-11-83-11-8 -0-11-4 0-11-4 3-11-8 3-11-8 0-4-01-7-134.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.17 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 0.00 (loc) 2-4 2-4 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=0-3-8, 2=0-3-8 Max Horz 2=39(LC 9) Max Uplift 2=-24(LC 12) Max Grav 4=137(LC 1), 2=221(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-11-4 to 2-0-12, Interior(1) 2-0-12 to 3-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss PB01 Truss Type Piggyback Qty 1 Ply 1 Waverley A Job Reference (optional) I50726106 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:39:55 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-RQtiwVScCbcAweDAsiDr326k98sqNwE0TKdEATzcB7Y Scale = 1:61.1 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 2 3 4 5 6 7 8 13 12 11 10 9 1 14 15 16 3x6 3x6 3x4 3x4 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 19-6-819-6-8 17-8-6 17-8-6 19-6-8 1-10-2 0-4-510-2-60-1-89-1-80-1-87.00 12 Plate Offsets (X,Y)-- [7:0-3-0,Edge], [9:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.65 0.48 0.26 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.06 -0.08 -0.00 (loc) 10-12 10-12 9 l/defl >999 >893 n/a L/d 240 180 n/a PLATES MT20 Weight: 63 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 1-5: 2x4 SPF No.2 BOT CHORD 2x4 SPF-S Stud *Except* 2-11: 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-9, 6-10 REACTIONS.All bearings 19-6-8. (lb) - Max Horz 1=260(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 12, 13, 10, 1 Max Grav All reactions 250 lb or less at joint(s) 9, 9, 2, 1 except 12=678(LC 17), 13=467(LC 17), 10=579(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-378/325, 2-3=-307/261 WEBS 4-12=-389/140, 3-13=-299/99, 6-10=-320/163 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-4-2 to 3-4-2, Interior(1) 3-4-2 to 17-8-6, Exterior(2E) 17-8-6 to 19-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 13, 10, 1. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss PB02 Truss Type GABLE Qty 9 Ply 1 Waverley A Job Reference (optional) I50726107 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:39:57 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-Oo?TLBUtkDsu9yNZz6GJ9TCANxaort0Jwe6LEMzcB7W Scale = 1:37.9 2 3 4 5 6 11 10 9 8 1 12 13 14 15 7 16 17 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 3x4 20-0-020-0-0 10-0-0 10-0-0 20-0-0 10-0-0 -0-0-45-9-125-10-00-1-00-1-87.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.29 0.32 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 55 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 6-9: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 20-0-0. (lb) - Max Horz 1=88(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 2, 11, 8, 6 except 1=-332(LC 17), 7=-305(LC 18) Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 2=588(LC 17), 10=329(LC 17), 11=481(LC 17), 8=480(LC 18), 6=576(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-300/97, 5-8=-300/97 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-4-2 to 3-4-2, Interior(1) 3-4-2 to 10-0-0, Exterior(2R) 10-0-0 to 13-0-0, Interior(1) 13-0-0 to 19-7-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 11, 8, 6 except (jt=lb) 1=332, 7=305. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss PB03 Truss Type Piggyback Qty 1 Ply 1 Waverley A Job Reference (optional) I50726108 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:39:58 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-s?ZrYXVVVW_ln5ylXqnYhgkKVLwiaILS9IrunozcB7V Scale = 1:38.3 2 3 4 5 6 7 12 11 10 9 1 13 14 15 16 8 17 18 5x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 3x4 19-6-819-6-8 10-0-0 10-0-0 19-6-8 9-6-8 0-4-55-8-80-1-80-2-150-1-120-1-87.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.33 0.34 0.24 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.07 0.00 (loc) 9-11 9-11 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 52 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 7-10: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 19-6-8. (lb) - Max Horz 1=-87(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 1, 8, 8, 2, 12, 9 Max Grav All reactions 250 lb or less at joint(s) 1, 8, 2, 7 except 11=638(LC 17), 12=498(LC 17), 9=505(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-11=-353/55, 3-12=-341/109, 6-9=-336/104 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-4-2 to 3-4-2, Interior(1) 3-4-2 to 10-0-0, Exterior(2R) 10-0-0 to 13-0-0, Interior(1) 13-0-0 to 19-4-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 8, 2, 12, 9. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss PB04 Truss Type Piggyback Qty 15 Ply 1 Waverley A Job Reference (optional) I50726109 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:39:59 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-KB7DmtV7Gq6cOFXx5XInEuHVUlGKJnncOxbSJEzcB7U Scale = 1:38.5 12 3 4 6 5 7 8 9 2x4 2x4 3x4 2x4 2x4 11-8-011-8-00-4-56-8-20-1-80-1-87.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.37 0.32 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.01 -0.00 (loc) 1 1 5 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 35 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=10-10-0, 2=10-10-0, 6=10-10-0 Max Horz 2=175(LC 9) Max Uplift 5=-15(LC 9), 6=-41(LC 12) Max Grav 5=257(LC 17), 2=208(LC 18), 6=645(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-388/162 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-4-2 to 3-4-2, Interior(1) 3-4-2 to 11-6-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss PB05 Truss Type Piggyback Qty 1 Ply 1 Waverley A Job Reference (optional) I50726110 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:00 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-oNgbzDWl18ET0P68fFp0m5qbu9Z?2BTldbK?rhzcB7T Scale = 1:61.1 2 3 4 5 6 7 8 13 12 11 10 9 1 14 15 16 3x6 3x6 3x4 3x4 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 19-6-819-6-8 17-8-6 17-8-6 19-6-8 1-10-2 0-4-510-2-60-1-89-1-80-1-87.00 12 Plate Offsets (X,Y)-- [7:0-3-0,Edge], [9:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.65 0.48 0.26 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.06 -0.08 -0.00 (loc) 10-12 10-12 9 l/defl >999 >893 n/a L/d 240 180 n/a PLATES MT20 Weight: 63 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 1-5: 2x4 SPF No.2 BOT CHORD 2x4 SPF-S Stud *Except* 2-11: 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-9, 6-10 REACTIONS.All bearings 19-6-8. (lb) - Max Horz 1=260(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 12, 13, 10, 1 Max Grav All reactions 250 lb or less at joint(s) 9, 9, 2, 1 except 12=678(LC 17), 13=467(LC 17), 10=579(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-378/325, 2-3=-307/261 WEBS 4-12=-389/140, 3-13=-299/99, 6-10=-320/163 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-4-2 to 3-4-2, Interior(1) 3-4-2 to 17-8-6, Exterior(2E) 17-8-6 to 19-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 13, 10, 1. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss PB06 Truss Type Piggyback Qty 12 Ply 1 Waverley A Job Reference (optional) I50726111 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:01 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-GZE_AZXNoRMJeZhKCyKFJJMqaZzVni1vrF4YN7zcB7S Scale = 1:30.4 1 2 3 4 5 6 4x6 2x4 2x4 2x4 8-0-08-0-0 4-0-0 4-0-0 8-0-0 4-0-0 0-5-104-6-80-1-80-5-100-1-814.00 12 Plate Offsets (X,Y)-- [2:0-2-10,0-1-0], [3:Edge,0-1-14], [4:0-2-10,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.40 0.21 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.01 0.01 0.00 (loc) 5 5 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=6-11-12, 4=6-11-12, 6=6-11-12 Max Horz 2=-85(LC 10) Max Uplift 2=-20(LC 12), 4=-20(LC 12) Max Grav 2=180(LC 1), 4=180(LC 1), 6=215(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-2-10 to 3-2-10, Interior(1) 3-2-10 to 4-0-0, Exterior(2R) 4-0-0 to 7-0-0, Interior(1) 7-0-0 to 7-9-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss PBE01 Truss Type GABLE Qty 1 Ply 1 Waverley A Job Reference (optional) I50726112 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:03 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-CyMkbEYeK3c1ttqiKNMjOkSEHMhAFccBJZZfS0zcB7Q Scale = 1:37.6 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 2 3 4 5 6 7 8 9 10 11 12 13 14 27 26 25 24 23 22 21 20 19 18 17 16 1 28 29 15 4x6 3x4 4x6 3x4 20-0-020-0-0 10-0-0 10-0-0 20-0-0 10-0-0 -0-0-45-9-125-10-00-1-00-1-87.00 12 Plate Offsets (X,Y)-- [21:0-3-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.07 0.07 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 14 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 78 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 14-21: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 20-0-0. (lb) - Max Horz 1=88(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 15, 24, 25, 26, 27, 19, 18, 17, 16 Max Grav All reactions 250 lb or less at joint(s) 1, 15, 2, 22, 23, 24, 25, 26, 27, 20, 19, 18, 17, 16, 14 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-4-2 to 3-4-0, Interior(1) 3-4-0 to 10-0-0, Exterior(2R) 10-0-0 to 13-0-0, Interior(1) 13-0-0 to 19-7-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 15, 24, 25, 26, 27, 19, 18, 17, 16. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss PBE02 Truss Type GABLE Qty 1 Ply 1 Waverley A Job Reference (optional) I50726113 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:04 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-g8w6paZG5MkuV0Pvu5uyxx_QJm2z_35LXDID_SzcB7P Scale = 1:30.1 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 2 3 4 5 6 7 8 14 13 12 11 10 1 9 4x6 8-0-08-0-0 4-0-0 4-0-0 8-0-0 4-0-0 -0-0-44-7-124-8-00-1-00-1-814.00 12 Plate Offsets (X,Y)-- [5:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.03 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 8 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-0-0. (lb) - Max Horz 1=-85(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 1, 9, 2, 8, 13, 14, 11, 10 Max Grav All reactions 250 lb or less at joint(s) 1, 9, 2, 8, 12, 13, 14, 11, 10 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-2-10 to 3-2-10, Interior(1) 3-2-10 to 4-0-0, Exterior(2R) 4-0-0 to 7-0-0, Interior(1) 7-0-0 to 7-9-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 1, 9, 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9, 2, 8, 13, 14, 11, 10. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss PBE03 Truss Type GABLE Qty 1 Ply 1 Waverley A Job Reference (optional) I50726114 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:06 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-dX2tEGbWd_?ckKZH?VwQ0M3iraibSy1e?XnJ3LzcB7N Scale = 1:33.3Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 1 17 18 3x4 11-8-011-8-0-0-0-46-9-106-9-66-8-20-1-87.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.30 0.08 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 10 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 54 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-8-0. (lb) - Max Horz 1=175(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 1, 10, 2, 11, 12, 13, 14, 15, 16 Max Grav All reactions 250 lb or less at joint(s) 1, 10, 2, 11, 12, 13, 14, 15, 16 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-318/265 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-4-2 to 3-4-2, Interior(1) 3-4-2 to 11-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 1, 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 10, 2, 11, 12, 13, 14, 15, 16. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss T01 Truss Type Roof Special Qty 9 Ply 1 Waverley A Job Reference (optional) I50726115 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:07 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-5jbFRcc8OH7TMU8UZDRfZactazySBCJnEBXtbnzcB7M Scale = 1:50.7 1 2 3 4 5 10 9 8 7 6 11 12 2x4 5x6 4x8 5x6 2x4 6x8 3x4 3x6 3x4 3x6 4-1-44-1-4 8-0-03-10-12 11-10-123-10-12 16-0-04-1-4 4-1-4 4-1-4 8-0-0 3-10-12 11-10-12 3-10-12 16-0-0 4-1-4 1-7-58-3-51-7-56-5-110.00 12 10.00 12 Plate Offsets (X,Y)-- [5:0-2-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.30 0.49 0.90 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.16 -0.33 0.58 (loc) 8 8 6 l/defl >999 >580 n/a L/d 240 180 n/a PLATES MT20 Weight: 68 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-8-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=0-3-8, 6=0-3-8 Max Horz 10=-146(LC 10) Max Grav 10=632(LC 1), 6=632(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-10=-627/68, 1-2=-1790/93, 2-3=-2290/0, 3-4=-2290/0, 4-5=-1790/62, 5-6=-621/46 BOT CHORD 8-9=-94/1843, 7-8=-47/1733 WEBS 3-8=0/2651, 4-8=-124/570, 4-7=-393/61, 5-7=-6/1406, 2-8=-37/448, 2-9=-393/59, 1-9=-1/1406 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-4 to 3-1-4, Interior(1) 3-1-4 to 8-0-0, Exterior(2R) 8-0-0 to 11-0-0, Interior(1) 11-0-0 to 15-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 10, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss T02 Truss Type Common Qty 3 Ply 1 Waverley A Job Reference (optional) I50726116 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:07 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-5jbFRcc8OH7TMU8UZDRfZacn5zwvBOwnEBXtbnzcB7M Scale: 3/16"=1' 1 2 3 4 5 8 7 6910 4x6 5x16 MT18HS 5x16 MT18HS2x4 7-10-07-10-0 15-8-07-10-0 -1-3-4 1-3-4 7-10-0 7-10-0 15-8-0 7-10-0 16-11-4 1-3-4 1-4-1110-6-51-4-1114.00 12 Plate Offsets (X,Y)-- [6:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.65 0.59 0.15 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.13 -0.20 0.01 (loc) 6-7 6-7 6 l/defl >999 >902 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 61 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-7: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 6=0-3-8 Max Horz 8=-235(LC 10) Max Uplift 8=-20(LC 12), 6=-20(LC 12) Max Grav 8=825(LC 18), 6=825(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-717/88, 3-4=-717/88, 2-8=-673/105, 4-6=-673/105 BOT CHORD 7-8=0/406, 6-7=0/406 WEBS 3-7=0/488 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-3-4 to 1-8-12, Interior(1) 1-8-12 to 7-10-0, Exterior(2R) 7-10-0 to 10-10-0, Interior(1) 10-10-0 to 16-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) The Fabrication Tolerance at joint 2 = 16%, joint 4 = 16% 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss T03 Truss Type Roof Special Qty 1 Ply 1 Waverley A Job Reference (optional) I50726117 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:08 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-Zw9dfycm9bFKzejg7wyu5n9zINFfwh1wSrGQ7DzcB7L Scale = 1:67.1 1 2 3 4 5 8 7 6910 3x8 3x4 3x6 3x16 MT18HS 3x6 4x6 2x4 3x4 9-10-139-10-13 19-11-810-0-11 6-8-1 6-8-1 13-1-9 6-5-9 19-11-8 6-9-15 12-0-110-5-07.00 12 Plate Offsets (X,Y)-- [1:0-0-13,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.63 0.69 0.80 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.37 -0.55 0.02 (loc) 6-8 6-8 5 l/defl >643 >433 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 81 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 1-8: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 1-8, 2-8 REACTIONS. (size)8=0-3-8, 5=Mechanical Max Horz 8=-319(LC 8) Max Uplift 8=-14(LC 8) Max Grav 8=986(LC 18), 5=885(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1075/74, 4-5=-1270/52 BOT CHORD 6-8=-13/608, 5-6=0/1053 WEBS 2-8=-852/86, 2-6=0/803, 4-6=-363/114 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 19-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) All plates are MT20 plates unless otherwise indicated. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss T04 Truss Type Common Qty 13 Ply 1 Waverley A Job Reference (optional) I50726118 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:09 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-16j?sIdOvuNBboIsgeT7e?h3inZrfCj4hV0zgfzcB7K Scale = 1:76.9 1 2 3 4 5 6 10 9 8 7 11 12 13 14 15 4x6 3x6 3x4 3x8 MT18HS4x8 3x6 4x6 2x4 4x6 3x6 6-0-66-0-6 16-9-010-8-10 27-10-011-1-0 6-0-6 6-0-6 13-2-2 7-1-12 20-3-14 7-1-12 27-10-0 7-6-2 9-7-613-1-100-5-07.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.90 0.82 0.52 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.41 -0.63 0.04 (loc) 7-9 6-7 6 l/defl >802 >525 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 130 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 6-8: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 3-7,5-7: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-9, 1-10 REACTIONS. (size)10=0-3-8, 6=Mechanical Max Horz 10=-310(LC 10) Max Grav 10=1326(LC 18), 6=1259(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-659/141, 2-3=-707/141, 3-5=-1663/65, 5-6=-1894/40, 1-10=-1233/62 BOT CHORD 9-10=-225/279, 7-9=0/1062, 6-7=0/1564 WEBS 2-9=-56/302, 3-9=-907/90, 3-7=0/861, 5-7=-400/122, 1-9=-49/979 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 6-0-6, Exterior(2R) 6-0-6 to 9-0-6, Interior(1) 9-0-6 to 27-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss T06 Truss Type Common Qty 2 Ply 1 Waverley A Job Reference (optional) I50726119 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:10 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-VIHN3ee1gCV2Dxt3EL_MACEIcBv?Oe2Dw9lXC6zcB7J Scale = 1:76.9 1 2 3 4 5 6 7 11 10 9 8 12 13 14 15 16 4x6 3x6 3x4 3x16 MT18HS4x8 3x6 4x6 2x4 4x6 3x6 6-0-66-0-6 16-9-010-8-10 27-10-011-1-0 6-0-6 6-0-6 13-2-2 7-1-12 20-3-14 7-1-12 27-10-0 7-6-2 28-9-4 0-11-4 9-7-613-1-100-5-07.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.70 0.82 0.51 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.42 -0.62 0.04 (loc) 8-10 8-10 6 l/defl >791 >534 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 131 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 6-9: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 3-8,5-8: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-9 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-10, 1-11 REACTIONS. (size)11=0-3-8, 6=0-3-8 Max Horz 11=-315(LC 10) Max Grav 11=1321(LC 18), 6=1314(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-657/141, 2-3=-705/141, 3-5=-1646/63, 5-6=-1873/37, 1-11=-1228/62 BOT CHORD 10-11=-233/287, 8-10=0/1058, 6-8=0/1538 WEBS 2-10=-56/300, 3-10=-898/91, 3-8=0/844, 5-8=-384/118, 1-10=-49/975 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 6-0-6, Exterior(2R) 6-0-6 to 9-0-6, Interior(1) 9-0-6 to 28-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss T07 Truss Type Piggyback Base Qty 1 Ply 1 Waverley A Job Reference (optional) I50726120 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:11 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-zVrmHzffRWdvr5SFo3WbjQnQlbG27CON8pV4kYzcB7I Scale = 1:52.1 1 2 3 4 5 6 11 10 9 8 7 12 13 14 15 16 6x6 4x6 3x6 3x6 2x4 3x4 5x8 3x6 5x8 6-6-06-6-0 14-6-08-0-0 21-0-06-6-0 -1-3-4 1-3-4 6-6-0 6-6-0 14-6-0 8-0-0 21-0-0 6-6-0 22-3-4 1-3-4 1-6-119-1-111-6-119-1-1114.00 12 Plate Offsets (X,Y)-- [2:0-2-4,0-1-12], [3:0-2-11,Edge], [4:0-3-2,0-2-0], [5:0-2-4,0-1-12], [7:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.87 0.71 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.27 -0.48 0.02 (loc) 8-9 8-9 7 l/defl >913 >515 n/a L/d 240 180 n/a PLATES MT20 Weight: 93 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-4: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-8: 2x4 SPF No.2, 2-11,5-7: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-8 REACTIONS. (size)11=0-3-8, 7=0-3-8 Max Horz 11=-212(LC 10) Max Uplift 11=-18(LC 12), 7=-18(LC 12) Max Grav 11=1075(LC 17), 7=1064(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-965/67, 3-4=-540/120, 4-5=-951/67, 2-11=-929/80, 5-7=-918/80 BOT CHORD 9-11=0/608, 8-9=0/612, 7-8=0/549 WEBS 3-9=0/390, 4-8=0/362 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-3-4 to 1-8-12, Interior(1) 1-8-12 to 6-6-0, Exterior(2R) 6-6-0 to 10-8-15, Interior(1) 10-8-15 to 14-6-0, Exterior(2R) 14-6-0 to 18-8-15, Interior(1) 18-8-15 to 22-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 7. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss T08 Truss Type Piggyback Base Qty 3 Ply 1 Waverley A Job Reference (optional) I50726121 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:11 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-zVrmHzffRWdvr5SFo3WbjQnQsbEY7CUN8pV4kYzcB7I Scale = 1:52.1 1 2 3 4 5 10 9 8 7 6 11 12 13 14 15 3x8 5x6 4x6 5x10 MT18HS 3x6 2x4 3x4 3x6 5x8 6-6-06-6-0 14-6-08-0-0 21-0-06-6-0 6-6-0 6-6-0 14-6-0 8-0-0 21-0-0 6-6-0 22-3-4 1-3-4 1-6-119-1-111-6-119-1-1114.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [3:0-3-2,0-2-0], [4:0-2-4,0-1-12], [6:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.86 0.87 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.31 -0.54 0.02 (loc) 7-8 7-8 6 l/defl >802 >455 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 91 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 2-3: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF No.2, 1-10,4-6: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-3. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-7 REACTIONS. (size)10=0-3-8, 6=0-3-8 Max Horz 10=-199(LC 10) Max Uplift 6=-18(LC 12) Max Grav 10=989(LC 17), 6=1067(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-950/64, 2-3=-543/120, 3-4=-956/66, 1-10=-822/62, 4-6=-922/80 BOT CHORD 8-10=0/611, 7-8=0/615, 6-7=0/552 WEBS 2-8=0/371, 3-7=0/366 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-2-12 to 3-2-12, Interior(1) 3-2-12 to 6-6-0, Exterior(2R) 6-6-0 to 10-8-15, Interior(1) 10-8-15 to 14-6-0, Exterior(2R) 14-6-0 to 18-8-15, Interior(1) 18-8-15 to 22-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss T09 Truss Type Piggyback Base Qty 1 Ply 1 Waverley A Job Reference (optional) I50726122 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:12 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-RhP8UJfHCplmSF0RMm1qGdJbY_XmseZWNTEeG_zcB7H Scale = 1:52.1 1 2 3 4 5 10 9 8 7 6 11 12 13 14 15 6x6 4x6 4x8 3x6 3x6 2x4 3x4 5x8 5x10 MT18HS 6-6-06-6-0 14-6-08-0-0 20-8-06-2-0 21-0-00-4-0 -1-3-4 1-3-4 6-6-0 6-6-0 14-6-0 8-0-0 20-8-0 6-2-0 21-0-0 0-4-0 1-6-119-1-110-3-89-1-1114.00 12 Plate Offsets (X,Y)-- [2:0-2-4,0-1-12], [3:0-2-11,Edge], [4:0-3-2,0-2-0], [6:0-4-8,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.86 1.00 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.36 -0.64 0.02 (loc) 7-8 7-8 6 l/defl >673 >381 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 91 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-4: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-7: 2x4 SPF No.2, 2-10,5-6: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 3-7 REACTIONS. (size)10=0-3-8, 6=0-3-8 Max Horz 10=202(LC 11) Max Uplift 10=-18(LC 12) Max Grav 10=1062(LC 17), 6=962(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-955/65, 3-4=-509/119, 4-5=-888/68, 2-10=-921/80, 5-6=-777/63 BOT CHORD 8-10=-36/586, 7-8=-35/590, 6-7=0/502 WEBS 3-8=0/406, 4-7=0/333 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-3-4 to 1-8-12, Interior(1) 1-8-12 to 6-6-0, Exterior(2R) 6-6-0 to 10-8-15, Interior(1) 10-8-15 to 14-6-0, Exterior(2R) 14-6-0 to 18-8-15, Interior(1) 18-8-15 to 20-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss T10 Truss Type Piggyback Base Qty 6 Ply 1 Waverley A Job Reference (optional) I50726123 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:13 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-wtzWifgvz7tc4PbdvUY3orsqyOvGb6wgc7_BpRzcB7G Scale = 1:52.1 1 2 3 4 9 8 7 6 5 10 11 12 13 14 3x8 5x6 4x6 3x8 5x10 MT18HS 3x6 2x4 3x4 5x10 MT18HS 6-6-06-6-0 14-6-08-0-0 20-8-06-2-0 21-0-00-4-0 6-6-0 6-6-0 14-6-0 8-0-0 20-8-0 6-2-0 21-0-0 0-4-0 1-6-119-1-110-3-89-1-1114.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [3:0-3-2,0-2-0], [5:0-4-8,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.63 0.85 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.35 -0.62 0.01 (loc) 6-7 6-7 5 l/defl >691 >394 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 89 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 2-3: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 5-8: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 2-6: 2x4 SPF No.2, 1-9,4-5: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-13 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-3. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-6 REACTIONS. (size)9=0-3-8, 5=0-3-8 Max Horz 9=182(LC 11) Max Grav 9=976(LC 17), 5=965(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-936/64, 2-3=-511/119, 3-4=-885/70, 1-9=-812/62, 4-5=-774/65 BOT CHORD 7-9=-35/588, 6-7=-34/592, 5-6=0/504 WEBS 2-7=0/386, 3-6=0/329 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-2-12 to 3-2-12, Interior(1) 3-2-12 to 6-6-0, Exterior(2R) 6-6-0 to 10-8-15, Interior(1) 10-8-15 to 14-6-0, Exterior(2R) 14-6-0 to 18-8-15, Interior(1) 18-8-15 to 20-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss T11 Truss Type Piggyback Base Qty 5 Ply 1 Waverley A Job Reference (optional) I50726124 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:14 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-O4Xuv?hXkR?TiZAqTB3IL2P0EoEBKNvprnjkLtzcB7F Scale = 1:83.0 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 20 21 22 23 24 25 26 27 28 29 30 31 3x6 5x6 3x6 5x6 3x6 3x4 4x8 3x4 3x8 3x4 5x6 5x6 4x6 3x6 3x6 5x10 MT18HS 4x8 6x6 9-2-49-2-4 18-2-08-11-12 28-2-010-0-0 38-0-09-10-0 38-2-00-2-0 43-6-85-4-8 -0-11-4 0-11-4 6-2-5 6-2-5 12-2-3 5-11-13 18-2-0 5-11-13 24-10-0 6-8-0 31-6-0 6-8-0 38-2-0 6-8-0 43-6-8 5-4-8 1-4-511-11-88-9-1411-11-87.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-4], [4:0-2-8,0-2-0], [6:0-4-0,0-2-4], [10:0-3-8,0-2-0], [11:0-2-8,Edge], [12:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.53 0.93 0.84 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.22 -0.37 0.07 (loc) 16-18 15-16 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 234 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 12-14: 2x4 SP 2400F 2.0E, 14-17: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 6-16,7-15,9-15,10-13: 2x4 SPF No.2, 7-16,9-13: 2x4 SPF 2100F 1.8E 4-19: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-9 oc purlins, except end verticals, and 2-0-0 oc purlins (4-7-7 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 18-19. WEBS 1 Row at midpt 5-16, 7-16, 7-15, 9-13, 10-13, 4-19, 11-13 REACTIONS. (size)12=Mechanical, 19=0-3-8, 13=0-3-8 Max Horz 19=288(LC 11) Max Uplift 12=-555(LC 25) Max Grav 19=1719(LC 17), 13=2952(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-375/76, 4-5=-2179/40, 5-6=-1619/89, 6-7=-1342/98, 7-9=-907/95, 9-10=-1/360, 10-11=-36/475, 2-19=-377/80, 11-12=0/625 BOT CHORD 18-19=-88/1931, 16-18=-73/1754, 15-16=-51/1159, 13-15=-65/585 WEBS 5-18=0/437, 5-16=-606/83, 6-16=0/470, 7-16=-17/486, 7-15=-801/54, 9-15=0/1287, 9-13=-1825/2, 10-13=-518/89, 4-19=-1974/0, 11-13=-606/58 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=44ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-11-4 to 3-5-0, Interior(1) 3-5-0 to 18-2-0, Exterior(2R) 18-2-0 to 24-3-15, Interior(1) 24-3-15 to 38-2-0, Exterior(2E) 38-2-0 to 43-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 12=555. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss T12 Truss Type Piggyback Base Qty 4 Ply 1 Waverley A Job Reference (optional) I50726125 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:15 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-sG4G7Li9Vk7KJjl01uaXtGxAQCaT3o1y3RTItJzcB7E Scale = 1:79.3 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 20 21 22 23 24 25 26 27 28 29 30 31 3x6 5x6 3x6 3x8 3x6 5x8 3x6 3x4 4x6 2x4 3x4 3x8 3x4 5x6 5x6 5x8 5x6 3x8 MT18HS 9-3-139-3-13 18-2-08-10-4 27-11-49-9-4 37-8-89-9-4 37-10-40-1-12 43-6-85-8-4 -0-11-4 0-11-4 6-4-6 6-4-6 12-3-3 5-10-13 18-2-0 5-10-13 24-8-3 6-6-3 31-2-5 6-6-3 37-8-8 6-6-3 38-2-0 0-5-8 43-6-8 5-4-8 0-4-510-11-811-11-88-9-141-0-011-11-87.00 12 Plate Offsets (X,Y)-- [2:0-8-0,0-0-6], [6:0-4-0,0-2-4], [10:0-5-0,0-1-12], [12:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.63 0.93 0.98 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.43 -0.68 -0.03 (loc) 14-15 14-15 12 l/defl >999 >663 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 215 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 16-18: 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 10-13: 2x4 SPF 2100F 1.8E, 6-17,7-17,7-15,8-15,8-14: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-8 oc purlins, except end verticals, and 2-0-0 oc purlins (4-3-11 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 17-19. WEBS 1 Row at midpt 10-13, 5-17, 7-15, 11-13 2 Rows at 1/3 pts 8-14 REACTIONS. (size)2=0-3-8, 13=0-3-8, 12=Mechanical Max Horz 2=281(LC 11) Max Uplift 2=-18(LC 12), 13=-30(LC 9), 12=-169(LC 13) Max Grav 2=1764(LC 17), 13=2476(LC 19), 12=192(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2826/39, 3-5=-2639/61, 5-6=-1833/122, 6-7=-1531/126, 7-8=-1192/142, 10-11=-149/301, 11-12=-147/270 BOT CHORD 2-19=-17/2486, 17-19=-25/2044, 15-17=0/1380, 14-15=-9/810 WEBS 13-14=-2123/49, 10-14=-445/122, 3-19=-306/95, 5-19=0/669, 5-17=-726/73, 6-17=0/598, 7-17=-38/398, 7-15=-706/55, 8-15=0/1248, 8-14=-1834/0, 11-13=-307/78 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=44ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-11-4 to 3-5-0, Interior(1) 3-5-0 to 18-2-0, Exterior(2R) 18-2-0 to 24-3-15, Interior(1) 24-3-15 to 38-2-0, Exterior(2E) 38-2-0 to 43-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 13 except (jt=lb) 12=169. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss T13 Truss Type Piggyback Base Qty 1 Ply 1 Waverley A Job Reference (optional) I50726126 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:16 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-KSefKhjnG2FBxsKCbc5mQTUKycwRoGH6I5CrPlzcB7D Scale = 1:71.4 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 23 24 25 26 27 28 3x6 5x6 3x6 3x4 3x8 3x8 3x6 4x6 2x4 3x4 3x8 3x4 5x6 5x6 3x8 MT18HS 9-3-139-3-13 18-2-08-10-4 27-10-09-8-0 37-8-89-10-8 -0-11-4 0-11-4 6-4-6 6-4-6 12-3-3 5-10-13 18-2-0 5-10-13 24-7-6 6-5-5 31-0-11 6-5-5 37-8-8 6-7-13 0-4-510-11-87.00 12 Plate Offsets (X,Y)-- [2:0-8-0,0-0-6], [6:0-4-0,0-2-4], [10:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.65 0.95 0.91 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.35 -0.55 0.08 (loc) 11-12 11-12 11 l/defl >999 >814 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 184 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 13-15: 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-16,5-16,5-14: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-7-13 oc purlins, except end verticals, and 2-0-0 oc purlins (4-3-2 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 14-16. WEBS 1 Row at midpt 10-11, 5-14, 7-12 2 Rows at 1/3 pts 9-11 REACTIONS. (size)11=Mechanical, 2=0-3-8 Max Horz 2=297(LC 9) Max Grav 11=1792(LC 17), 2=1805(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2904/0, 3-5=-2717/8, 5-6=-1914/67, 6-7=-1601/78, 7-9=-1246/72 BOT CHORD 2-16=-79/2544, 14-16=-86/2104, 12-14=-57/1468, 11-12=-68/938 WEBS 3-16=-305/96, 5-16=0/667, 5-14=-725/74, 6-14=0/620, 7-14=-50/350, 7-12=-659/60, 9-12=0/1171, 9-11=-1733/17 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=38ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-11-4 to 2-10-0, Interior(1) 2-10-0 to 18-2-0, Exterior(2R) 18-2-0 to 23-6-0, Interior(1) 23-6-0 to 37-6-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss T14 Truss Type Piggyback Base Qty 1 Ply 1 Waverley A Job Reference (optional) I50726127 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:17 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-oeC1X1jQ1MN2Z0vP8Jd?zh1W6?J0XqCFXlyPyCzcB7C Scale: 3/16"=1' 1 2 3 4 5 6 7 8 13 12 11 10 9 14 15 16 17 18 19 20 21 3x6 4x6 3x4 3x4 3x6 3x4 2x4 3x4 3x8 3x4 3x4 3x6 10-1-1210-1-12 18-2-08-0-4 24-0-05-10-0 29-10-05-10-0 -0-11-4 0-11-4 6-4-6 6-4-6 12-3-3 5-10-13 18-2-0 5-10-13 24-0-0 5-10-0 29-10-0 5-10-0 0-4-510-11-87.00 12 Plate Offsets (X,Y)-- [2:0-2-4,0-1-8], [6:0-3-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.62 0.73 0.49 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.25 -0.51 0.01 (loc) 2-13 2-13 9 l/defl >489 >238 n/a L/d 240 180 n/a PLATES MT20 Weight: 152 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-13,5-13,5-11: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-8. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-9, 5-13, 6-11, 7-10 REACTIONS. (size)9=Mechanical, 2=0-3-8, 13=0-3-8 Max Horz 2=297(LC 9) Max Uplift 9=-51(LC 9) Max Grav 9=899(LC 17), 2=413(LC 18), 13=1558(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-283/97, 5-6=-563/93, 6-7=-408/92, 7-8=-407/101, 8-9=-776/68 BOT CHORD 10-11=-86/392 WEBS 3-13=-363/96, 5-13=-939/53, 5-11=0/352, 7-10=-431/133, 8-10=-51/751 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-11-4 to 2-0-12, Interior(1) 2-0-12 to 18-2-0, Exterior(2R) 18-2-0 to 22-4-15, Interior(1) 22-4-15 to 29-8-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss T15 Truss Type Piggyback Base Qty 6 Ply 1 Waverley A Job Reference (optional) I50726128 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:18 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-GrmPlNk2ofVvAAUbi18EVuZiZPffGCePlPhyUezcB7B Scale = 1:72.7 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 18 19 20 21 22 23 24 25 3x6 4x6 3x8 3x8 3x6 2x4 3x4 2x4 2x4 3x8 2x4 4x6 6x8 3x8 3x4 5x8 10-1-1210-1-12 12-2-02-0-4 18-2-06-0-0 27-11-89-9-8 29-10-01-10-8 -0-11-4 0-11-4 5-3-11 5-3-11 10-1-12 4-10-1 12-2-0 2-0-4 18-2-0 6-0-0 23-0-12 4-10-12 27-11-8 4-10-12 29-10-0 1-10-8 0-4-510-11-80-8-07.00 12 Plate Offsets (X,Y)-- [2:0-3-3,0-1-8], [7:0-3-8,0-2-0], [13:0-2-4,0-2-8], [15:0-4-8,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.57 0.71 0.79 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.44 -0.68 0.03 (loc) 13-14 13-14 11 l/defl >531 >343 n/a L/d 240 180 n/a PLATES MT20 Weight: 166 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 13-15: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 10-11,9-12,8-14,8-13: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 7-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 10-11, 6-16, 9-12, 7-14, 8-13 REACTIONS. (size)11=Mechanical, 2=0-3-8, 17=0-3-8 Max Horz 2=297(LC 9) Max Uplift 11=-51(LC 9), 2=-1(LC 12) Max Grav 11=868(LC 17), 2=418(LC 18), 17=1548(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-326/67, 6-7=-617/78, 7-8=-453/79, 10-11=-812/45 BOT CHORD 13-14=-104/394 WEBS 6-15=-749/10, 3-17=-354/87, 5-17=-925/113, 5-15=-97/701, 6-14=0/407, 8-13=-497/64, 10-13=-92/827 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-11-4 to 2-0-12, Interior(1) 2-0-12 to 18-2-0, Exterior(2R) 18-2-0 to 22-4-15, Interior(1) 22-4-15 to 29-8-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 2. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss T16 Truss Type Piggyback Base Qty 1 Ply 1 Waverley A Job Reference (optional) I50726129 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:19 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-k1KnyilgZzdmoK3nGkfT266t_p?Y?fhY_3RV04zcB7A Scale = 1:71.4 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 19 20 21 22 23 24 25 26 27 28 3x6 5x6 3x6 3x4 3x8 3x6 3x6 4x6 2x4 3x4 3x8 3x4 3x4 3x4 3x8 MT18HS 10-1-1210-1-12 18-2-08-0-4 27-10-09-8-0 37-8-89-10-8 -0-11-4 0-11-4 6-4-6 6-4-6 12-3-3 5-10-13 18-2-0 5-10-13 24-7-6 6-5-5 31-0-11 6-5-5 37-8-8 6-7-13 0-4-510-11-87.00 12 Plate Offsets (X,Y)-- [2:0-3-3,0-1-8], [6:0-4-0,0-2-4], [10:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.47 0.67 0.81 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.33 -0.51 0.02 (loc) 11-12 11-12 11 l/defl >999 >644 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 184 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 13-15: 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-16,5-16,5-14: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 10-11, 5-16, 6-14, 7-14, 7-12, 9-11 REACTIONS. (size)11=Mechanical, 2=0-3-8, 16=0-3-8 Max Horz 2=297(LC 9) Max Uplift 11=-15(LC 9) Max Grav 11=1283(LC 17), 2=426(LC 18), 16=1897(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-305/58, 5-6=-892/75, 6-7=-695/85, 7-9=-831/75 BOT CHORD 14-16=-149/335, 12-14=-82/856, 11-12=-81/640 WEBS 3-16=-361/96, 5-16=-1306/40, 5-14=0/609, 7-14=-311/15, 9-12=0/642, 9-11=-1139/40 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=38ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-11-4 to 2-10-0, Interior(1) 2-10-0 to 18-2-0, Exterior(2R) 18-2-0 to 23-6-0, Interior(1) 23-6-0 to 37-6-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss TG01 Truss Type Common Girder Qty 1 Ply 2 Waverley A Job Reference (optional) I50726130 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:21 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-hQSYNOmw5auU1eCAN9hx7XBAdddNTdBrSNwc5zzcB78 Scale = 1:50.7 1 2 3 4 7 6 58910111213 3x8 4x6 5x10 MT18HS 5x10 MT18HS3x12 3x8 5-9-125-9-12 11-7-85-9-12 5-9-12 5-9-12 11-7-8 5-9-12 12-10-12 1-3-4 1-4-118-2-11-4-1114.00 12 Plate Offsets (X,Y)-- [5:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.65 0.90 0.55 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.07 -0.13 0.01 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 115 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x8 SP 2400F 2.0E *Except* 2-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-3-8, 5=0-3-8 Max Horz 7=-178(LC 25) Max Grav 7=3491(LC 2), 5=3124(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2350/0, 2-3=-2375/0, 1-7=-1859/0, 3-5=-1971/0 BOT CHORD 6-7=0/1441, 5-6=0/1441 WEBS 2-6=0/3209 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-6-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1180 lb down at 1-6-12, 1166 lb down at 3-6-12, 1169 lb down at 5-6-12, and 1165 lb down at 7-6-12, and 822 lb down at 9-6-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Continued on page 2 March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss TG01 Truss Type Common Girder Qty 1 Ply 2 Waverley A Job Reference (optional) I50726130 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:21 2022 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-hQSYNOmw5auU1eCAN9hx7XBAdddNTdBrSNwc5zzcB78 LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 6=-1085(B) 8=-1085(B) 10=-1085(B) 11=-1085(B) 13=-770(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss TG02 Truss Type Common Girder Qty 1 Ply 2 Waverley A Job Reference (optional) I50726131 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:22 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-9c?wbknYsu0LfnnMxsCAfkkOG06kC0A_g0fAdPzcB77 Scale: 3/16"=1' 1 2 3 4 7 6 589101112131415 4x8 3x8 5x10 MT18HS 5x10 MT18HS3x12 3x8 7-10-07-10-0 15-8-07-10-0 -1-3-4 1-3-4 7-10-0 7-10-0 15-8-0 7-10-0 1-4-1110-6-51-4-1114.00 12 Plate Offsets (X,Y)-- [3:Edge,0-2-0], [5:Edge,0-2-8], [6:0-6-4,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.47 0.38 0.82 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.08 -0.15 0.01 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 186 lb FT = 20% GRIP 197/144 244/190 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x8 SP 2400F 2.0E WEBS 2x8 SP 2400F 2.0E *Except* 3-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-3-8, 5=0-3-8 Max Horz 7=222(LC 7) Max Grav 7=5228(LC 2), 5=5671(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3534/0, 3-4=-3520/0, 2-7=-2857/0, 4-5=-2760/0 BOT CHORD 6-7=0/2190, 5-6=0/2190 WEBS 3-6=0/4791 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1180 lb down at 1-2-12, 1168 lb down at 3-2-12, 1165 lb down at 5-2-12, 1169 lb down at 7-2-12, 1165 lb down at 9-2-12, 1165 lb down at 11-2-12, and 1174 lb down at 13-2-12, and 1192 lb down at 15-4-6 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Continued on page 2 March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss TG02 Truss Type Common Girder Qty 1 Ply 2 Waverley A Job Reference (optional) I50726131 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:22 2022 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-9c?wbknYsu0LfnnMxsCAfkkOG06kC0A_g0fAdPzcB77 LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 5=-1092(B) 8=-1085(B) 10=-1085(B) 11=-1085(B) 12=-1085(B) 13=-1085(B) 14=-1085(B) 15=-1085(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss TG03 Truss Type Piggyback Base Girder Qty 1 Ply 1 Waverley A Job Reference (optional) I50726132 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:23 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-doZIo4oAcC8CHxMYVajPCyHUmQQkxUo8vgPj9rzcB76 Scale = 1:55.4 1 2 3 4 9 8 7 6 5 10 11 12 13 14 15 16 17 18 19 20 6x8 5x10 MT18HS 5x10 MT18HS 6x8 5x10 MT18HS 4x6 6x8 5x10 MT18HS8x8 6-6-06-6-0 14-6-08-0-0 20-8-06-2-0 21-0-00-4-0 6-6-0 6-6-0 14-6-0 8-0-0 20-8-0 6-2-0 21-0-0 0-4-0 1-6-119-1-110-5-89-1-1114.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-5], [2:0-6-8,0-1-4], [3:0-6-8,0-1-4], [4:Edge,0-1-5], [5:0-5-0,0-1-8], [6:0-4-0,0-4-8], [7:0-3-4,0-4-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.80 0.46 0.74 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.11 -0.17 0.01 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 120 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x3 SPF No.2 *Except* 2-6: 2x4 SPF No.2, 1-9,4-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-1-8 oc purlins, except end verticals, and 2-0-0 oc purlins (5-4-0 max.): 2-3. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 2-7, 3-6 REACTIONS. (size)9=0-3-8, 5=0-3-8 Max Horz 9=179(LC 7) Max Uplift 9=-1276(LC 5), 5=-1058(LC 5) Max Grav 9=2825(LC 38), 5=3138(LC 38) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2524/1221, 2-3=-1668/738, 3-4=-2679/1075, 1-9=-2261/1022, 4-5=-2502/955 BOT CHORD 7-9=-246/385, 6-7=-827/1658 WEBS 2-7=-969/1368, 2-6=0/622, 3-6=-759/1618, 1-7=-699/1342, 4-6=-683/1608 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) The Fabrication Tolerance at joint 2 = 16% 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 9=1276, 5=1058. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 575 lb up at 2-0-12, 575 lb up at 4-0-12, 575 lb up at 6-0-12, 575 lb up at 8-0-12, 575 lb up at 10-0-12, 197 lb down and 206 lb up at 12-0-12, 197 lb down and 206 lb up at 14-0-12, and 197 lb down and 206 lb up at 16-0-12, and 197 lb down and 206 lb up at 18-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-9=-220(F=-200) Continued on page 2 March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss TG03 Truss Type Piggyback Base Girder Qty 1 Ply 1 Waverley A Job Reference (optional) I50726132 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:23 2022 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-doZIo4oAcC8CHxMYVajPCyHUmQQkxUo8vgPj9rzcB76 LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 12=238(F) 13=238(F) 14=238(F) 15=238(F) 16=238(F) 17=46(F) 18=46(F) 19=46(F) 20=46(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V01 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726133 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:24 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-5?7g?QppNVG3u5xl3HFel9ppUqrpg5jH8K8GhIzcB75 Scale = 1:56.2 1 2 3 4 5 8 7 63x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 15-4-515-4-5 15-4-80-0-3 7-8-4 7-8-4 15-4-8 7-8-4 0-0-48-11-100-0-414.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.16 0.15 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 56 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-7 REACTIONS.All bearings 15-4-1. (lb) - Max Horz 1=-166(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 1 except 8=-129(LC 12), 6=-129(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=309(LC 17), 8=484(LC 17), 6=484(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-319/204, 4-6=-319/204 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 7-8-4, Exterior(2R) 7-8-4 to 10-8-4, Interior(1) 10-8-4 to 15-0-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=129, 6=129. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V02 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726134 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:25 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-ZBh2DmqR8pOwWFWxc?mtHNM_OEA_PXRRM_uqEkzcB74 Scale = 1:49.1 1 2 3 4 5 8 7 69103x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-30-0-3 13-4-813-4-5 6-8-4 6-8-4 13-4-8 6-8-4 0-0-47-9-100-0-414.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.15 0.15 0.15 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 13-4-1. (lb) - Max Horz 1=-143(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-115(LC 12), 6=-115(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=317(LC 17), 8=418(LC 17), 6=417(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-290/188, 4-6=-290/188 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 6-8-4, Exterior(2R) 6-8-4 to 9-8-4, Interior(1) 9-8-4 to 13-0-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=115, 6=115. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V03 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726135 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:26 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-1NFQQ6q3v7Wm8P57AiH6qau98eXz8?OabedNmAzcB73 Scale = 1:42.1 1 2 3 4 5 8 7 63x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 11-4-511-4-5 11-4-80-0-3 5-8-4 5-8-4 11-4-8 5-8-4 0-0-46-7-100-0-414.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.15 0.10 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-4-1. (lb) - Max Horz 1=-121(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-112(LC 12), 6=-112(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=335(LC 17), 6=335(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-293/194, 4-6=-293/194 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 5-8-4, Exterior(2R) 5-8-4 to 8-8-4, Interior(1) 8-8-4 to 11-0-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=112, 6=112. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V04 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726136 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:26 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-1NFQQ6q3v7Wm8P57AiH6qau5aeWz8?WabedNmAzcB73 Scale = 1:36.0 1 2 3 42x4 4x6 2x4 2x4 0-0-30-0-3 9-4-89-4-5 4-8-4 4-8-4 9-4-8 4-8-4 0-0-45-5-100-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.44 0.17 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 28 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=9-4-1, 3=9-4-1, 4=9-4-1 Max Horz 1=98(LC 11) Max Uplift 1=-7(LC 12), 3=-7(LC 12) Max Grav 1=204(LC 1), 3=204(LC 1), 4=292(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 4-8-4, Exterior(2R) 4-8-4 to 7-8-4, Interior(1) 7-8-4 to 9-0-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V05 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726137 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:27 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-VappeSrhgQedlZgKkQoLMoRHU1rntTZjqINwIdzcB72 Scale = 1:28.9 1 2 3 42x4 4x6 2x4 2x4 0-0-30-0-3 7-4-87-4-5 3-8-4 3-8-4 7-4-8 3-8-4 0-0-44-3-100-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.37 0.19 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-4-1, 3=7-4-1, 4=7-4-1 Max Horz 1=-76(LC 10) Max Uplift 1=-17(LC 12), 3=-17(LC 12) Max Grav 1=168(LC 1), 3=168(LC 1), 4=209(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 3-8-4, Exterior(2R) 3-8-4 to 6-8-4, Interior(1) 6-8-4 to 7-0-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V06 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726138 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:28 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-_mNBrnsJRkmUNjFWI7Jav?_VJRDXcvEt3y6Uq3zcB71 Scale = 1:21.8 1 2 3 42x4 4x6 2x4 2x4 0-0-30-0-3 5-4-85-4-5 2-8-4 2-8-4 5-4-8 2-8-4 0-0-43-1-100-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.17 0.10 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-4-1, 3=5-4-1, 4=5-4-1 Max Horz 1=-53(LC 10) Max Uplift 1=-12(LC 12), 3=-12(LC 12) Max Grav 1=118(LC 1), 3=118(LC 1), 4=147(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V07 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726139 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:29 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-SyxZ37txC2uL?sqirrqpSDWiwramLMd0Hcs1NVzcB70 Scale = 1:12.7 1 2 3 4 2x4 4x6 2x4 2x4 3-4-53-4-5 3-4-80-0-3 1-8-4 1-8-4 3-4-8 1-8-4 0-0-41-11-100-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.03 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-4-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-4-1, 3=3-4-1, 4=3-4-1 Max Horz 1=-31(LC 10) Max Uplift 1=-7(LC 12), 3=-7(LC 12) Max Grav 1=68(LC 1), 3=68(LC 1), 4=85(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V08 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726140 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:29 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-SyxZ37txC2uL?sqirrqpSDWgMrZgLL80Hcs1NVzcB70 Scale = 1:41.9 1 2 3 4 5 8 7 63x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-30-0-3 11-4-011-3-13 5-8-0 5-8-0 11-4-0 5-8-0 0-0-46-7-50-0-414.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.15 0.10 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-3-9. (lb) - Max Horz 1=120(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-112(LC 12), 6=-112(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=335(LC 17), 6=335(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-294/194, 4-6=-294/194 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 5-8-0, Exterior(2R) 5-8-0 to 8-8-0, Interior(1) 8-8-0 to 11-0-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=112, 6=112. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V09 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726141 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:30 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-w9UxGTtZzL0Cc0OvPYL2_Q3ndFuw4oWAWGbbvxzcB7? Scale = 1:35.8 1 2 3 42x4 4x6 2x4 2x4 0-0-30-0-3 9-4-09-3-13 4-8-0 4-8-0 9-4-0 4-8-0 0-0-45-5-50-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.44 0.17 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 28 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=9-3-9, 3=9-3-9, 4=9-3-9 Max Horz 1=-98(LC 10) Max Uplift 1=-7(LC 12), 3=-7(LC 12) Max Grav 1=203(LC 1), 3=203(LC 1), 4=291(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 4-8-0, Exterior(2R) 4-8-0 to 7-8-0, Interior(1) 7-8-0 to 9-0-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V10 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726142 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:31 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-OL2JTpuCkf83EAz5zFtHXeczXfDmpGZJlwL8ROzcB7_ Scale = 1:28.8 1 2 3 42x4 4x6 2x4 2x4 0-0-30-0-3 7-4-07-3-13 3-8-0 3-8-0 7-4-0 3-8-0 0-0-44-3-50-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.37 0.19 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-3-9, 3=7-3-9, 4=7-3-9 Max Horz 1=-75(LC 10) Max Uplift 1=-16(LC 12), 3=-16(LC 12) Max Grav 1=167(LC 1), 3=167(LC 1), 4=207(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 3-8-0, Exterior(2R) 3-8-0 to 6-8-0, Interior(1) 6-8-0 to 7-0-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V11 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726143 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:33 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-KjA4uVwSGGOnTU7T4gvlc3hM5SwkHATcCEqFVGzcB6y Scale = 1:21.6 1 2 3 42x4 4x6 2x4 2x4 5-3-135-3-13 5-4-00-0-3 2-8-0 2-8-0 5-4-0 2-8-0 0-0-43-1-50-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.17 0.10 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-3-9, 3=5-3-9, 4=5-3-9 Max Horz 1=-53(LC 10) Max Uplift 1=-12(LC 12), 3=-12(LC 12) Max Grav 1=117(LC 1), 3=117(LC 1), 4=145(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V12 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726144 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:34 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-owkS6rw41aWe5eigeOQ_9GEZisHy0dulRuZo1jzcB6x Scale = 1:12.6 1 2 3 4 2x4 4x6 2x4 2x4 3-4-03-4-0 1-8-0 1-8-0 3-4-0 1-8-0 0-0-41-11-50-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.03 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-4-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-4-0, 3=3-4-0, 4=3-4-0 Max Horz 1=-30(LC 10) Max Uplift 1=-7(LC 12), 3=-7(LC 12) Max Grav 1=67(LC 1), 3=67(LC 1), 4=84(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V14 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726145 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:34 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-owkS6rw41aWe5eigeOQ_9GEUqsFC0c1lRuZo1jzcB6x Scale = 1:40.6 1 2 3 4 7 6 53x4 2x4 3x4 2x4 2x4 2x4 2x4 12-1-3 12-1-3 0-0-47-0-117.00 12 Plate Offsets (X,Y)-- [5:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.36 0.14 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-0-12. (lb) - Max Horz 1=183(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=441(LC 17), 7=379(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-269/215 WEBS 3-6=-262/136 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 11-11-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6, 7. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V15 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726146 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:35 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-G6IqJBxioueVjnHsC5xDhUmgTGctl4OvgYJMZ9zcB6w Scale = 1:28.2 1 2 3 5 4 6 2x4 2x4 2x4 2x4 2x4 8-1-3 8-1-3 0-0-44-8-117.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.24 0.12 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=8-0-12, 4=8-0-12, 5=8-0-12 Max Horz 1=119(LC 9) Max Uplift 4=-10(LC 9), 5=-29(LC 12) Max Grav 1=114(LC 18), 4=123(LC 17), 5=373(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-280/138 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 7-11-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V16 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726147 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:36 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-lIsCXWyKZBmMKxs2mpSSEhJpBgwIUXV2uC2v6bzcB6v Scale = 1:14.8 1 2 3 4 2x4 2x4 2x4 4-1-3 4-1-3 0-0-42-4-117.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.37 0.23 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-1-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-0-12, 3=4-0-12 Max Horz 1=55(LC 9) Max Uplift 3=-2(LC 9) Max Grav 1=138(LC 1), 3=138(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 3-11-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V17 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726148 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:36 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-lIsCXWyKZBmMKxs2mpSSEhJqmgxfUX02uC2v6bzcB6v Scale = 1:25.7 1 2 3 42x4 4x6 2x4 2x4 0-0-30-0-3 6-5-86-5-5 3-2-12 3-2-12 6-5-8 3-2-12 0-0-43-9-30-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.27 0.15 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=6-5-1, 3=6-5-1, 4=6-5-1 Max Horz 1=66(LC 11) Max Uplift 1=-14(LC 12), 3=-14(LC 12) Max Grav 1=145(LC 1), 3=145(LC 1), 4=180(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V18 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726149 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:37 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-DVPbkszyJVvDy5RFJWzhmvs213JAD_YC7soSe2zcB6u Scale = 1:15.8 1 2 3 4 2x4 4x6 2x4 2x4 4-5-54-5-5 4-5-80-0-3 2-2-12 2-2-12 4-5-8 2-2-12 0-0-42-7-30-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.11 0.06 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-5-1, 3=4-5-1, 4=4-5-1 Max Horz 1=43(LC 11) Max Uplift 1=-9(LC 12), 3=-9(LC 12) Max Grav 1=95(LC 1), 3=95(LC 1), 4=118(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V19 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726150 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:38 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-hhzzxC_b4p13aF0RtEVwJ6OE9TeQyR?LMWX0AUzcB6t Scale = 1:10.0 1 2 3 2x4 3x4 2x4 2-5-52-5-5 2-5-80-0-3 1-2-12 1-2-12 2-5-8 1-2-12 0-0-41-5-30-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.02 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-5-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-5-1, 3=2-5-1 Max Horz 1=-21(LC 10) Max Grav 1=73(LC 1), 3=73(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V20 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726151 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:38 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-hhzzxC_b4p13aF0RtEVwJ6ODETecyR?LMWX0AUzcB6t Scale = 1:9.7 1 2 3 2x4 2x4 2x4 2-4-3 2-4-3 0-0-41-4-77.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.08 0.05 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-4-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-3-12, 3=2-3-12 Max Horz 1=27(LC 11) Max Uplift 3=-1(LC 9) Max Grav 1=68(LC 1), 3=68(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V21 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726152 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:41 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-5Gf5aE0TNkPeRik0YM2exl0gkhdz9o4n2UmgnpzcB6q Scale = 1:22.6 1 2 3 5 4 6 7 2x4 2x4 2x4 2x4 2x4 6-4-3 6-4-3 0-0-43-8-77.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.32 0.20 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=6-3-12, 4=6-3-12, 5=6-3-12 Max Horz 1=91(LC 11) Max Uplift 1=-15(LC 10), 4=-7(LC 9), 5=-25(LC 12) Max Grav 1=42(LC 9), 4=128(LC 17), 5=320(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 6-2-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V22 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726153 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:43 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-1fns?w1jvLfMg0uOgn460A61AUKMdhx4VoFnrhzcB6o Scale = 1:35.0 1 2 3 4 7 6 5 8 9 102x4 2x4 2x4 2x4 2x4 2x4 2x4 10-4-3 10-4-3 0-0-46-0-77.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.26 0.14 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 10-3-12. (lb) - Max Horz 1=155(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=446(LC 17), 7=295(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-271/130 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 10-2-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 6, 7. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V23 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726154 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:45 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-_1ucQb3_Ryv4wK2nnC7a5bBKEI_m5a1Nz6ktwazcB6m Scale = 1:46.5 1 2 3 4 7 6 583x4 3x4 3x4 2x4 2x4 2x4 2x4 13-11-2 13-11-2 0-0-48-1-87.00 12 Plate Offsets (X,Y)-- [5:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.48 0.21 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 46 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5 REACTIONS.All bearings 13-10-11. (lb) - Max Horz 1=212(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=427(LC 17), 7=527(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-280/238 WEBS 2-7=-322/131 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 13-9-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6, 7. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V24 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726155 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:49 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-so87Fz6UVBPWOxLY01BWGRL3?vNj1O9zuji53LzcB6i Scale = 1:37.3 1 2 3 4 7 6 5 8 9 3x4 2x4 2x4 2x4 2x4 2x4 2x4 11-0-13 11-0-13 0-0-46-5-87.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.30 0.14 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 35 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-0-6. (lb) - Max Horz 1=166(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=453(LC 17), 7=322(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-269/128 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 10-11-9 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6, 7. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V25 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726156 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:49 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-so87Fz6UVBPWOxLY01BWGRL4pvO61Pqzuji53LzcB6i Scale = 1:28.6 1 2 3 5 4 6 7 2x4 2x4 2x4 2x4 2x4 8-2-8 8-2-8 0-0-44-9-87.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.25 0.12 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=8-2-2, 4=8-2-2, 5=8-2-2 Max Horz 1=121(LC 9) Max Uplift 4=-11(LC 9), 5=-29(LC 12) Max Grav 1=118(LC 18), 4=122(LC 17), 5=378(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-283/138 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 8-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V26 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726157 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:50 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-K?iVTJ76GVXM05wlaliloeu75Jd5msz66NRebnzcB6h Scale = 1:19.0 1 2 3 4 5 2x4 2x4 2x4 5-4-4 5-4-4 0-0-43-1-87.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.73 0.46 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-3-13, 3=5-3-13 Max Horz 1=75(LC 9) Max Uplift 3=-3(LC 9) Max Grav 1=188(LC 1), 3=188(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 5-3-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V27 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726158 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:51 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-oBGtgf8k0ofDeFVx8SE_LsRD7jx0VJDGL1BC8EzcB6g Scale = 1:21.5 1 2 3 4 5 2x4 2x4 2x4 6-0-2 6-0-2 0-0-43-6-17.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.97 0.60 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-11-11, 3=5-11-11 Max Horz 1=86(LC 9) Max Uplift 3=-3(LC 9) Max Grav 1=215(LC 1), 3=215(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 5-10-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V28 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726159 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:52 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-HNqGu?8Nn6n4FP47iAlDt3zZJ6OSElPPahwlggzcB6f Scale = 1:30.7 1 2 3 5 4 6 7 2x4 2x4 2x4 2x4 2x4 8-10-6 8-10-6 0-0-45-2-17.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.30 0.14 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=8-9-15, 4=8-9-15, 5=8-9-15 Max Horz 1=131(LC 9) Max Uplift 4=-12(LC 9), 5=-32(LC 12) Max Grav 1=141(LC 18), 4=116(LC 17), 5=411(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-308/143 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 8-9-2 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V29 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726160 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:53 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-laNe5L9?YQwxtYfJFtGSQHWjNWkfzCuYoLgJC6zcB6e Scale = 1:39.4 1 2 3 4 7 6 5 8 3x4 2x4 2x4 2x4 2x4 2x4 2x4 11-8-11 11-8-11 0-0-46-10-17.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.34 0.14 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 38 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-8-4. (lb) - Max Horz 1=177(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=446(LC 17), 7=356(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-265/125 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-8-11, Interior(1) 3-8-11 to 11-7-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6, 7. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job WAVERLEY_A Truss V30 Truss Type Valley Qty 1 Ply 1 Waverley A Job Reference (optional) I50726161 8.430 s Aug 16 2021 MiTek Industries, Inc. Thu Mar 10 22:40:53 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:lnsQMS9wyRwvEXxIWGdAmkyvvWA-laNe5L9?YQwxtYfJFtGSQHWgRWkLzAHYoLgJC6zcB6e Scale = 1:48.6 1 2 3 4 5 6 10 9 8 711 3x6 3x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 14-6-1514-6-15 14-6-15 14-6-15 0-0-48-6-17.00 12 Plate Offsets (X,Y)-- [7:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.53 0.16 0.22 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 49 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-3: 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-7 REACTIONS.All bearings 14-6-8. (lb) - Max Horz 1=222(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 7, 1, 8, 9, 10 Max Grav All reactions 250 lb or less at joint(s) 7, 1 except 8=475(LC 17), 9=398(LC 17), 10=313(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-309/250, 2-4=-258/217 WEBS 5-8=-261/119 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 14-5-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 1, 8, 9, 10. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 11,2022 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths