HomeMy WebLinkAbout06010136-Site Plan
..
Note:
Contmctor should verify site
spedficlr'lformatJon depicted
hereon with the approved
construction plans for this
development
&@@[)flfJUj)@@ 1m@!J'lilJD
~@OOO@g '[]" = ~@'
Gar. FFE = 912.2
1 st Fir FFE = 914.0
Bsmt FFE = 904.2
Drive Slope '= 2.1 %
BUCKINGHAM - ELEV 1C
LEFT HAND - Brick 3 Sides
FULL BSMT - 9' Walls
3 CAR - Side Entry
Note:
Minimum Front yard. Variable
Minimum Between Residences _ 6'
Minimum Rear Yard _ 20'
SAN MH
TC=911.70
STM INLET
TC=909.DO STM SEWER
1 <:
,- ; I~
I~
.8' la I~
I" (5
m <:
0 I I 0::: <.\
~ . Cl m
1 "
0 --- . M
0 uj I 1 ~~
~ ci ,p "
DO ,. . 5 u ~ 1
in I " " wOo . "- C
~ ~~~ 1 12 0
~ - I~
'Jo~ I /' 0 LO
I ::2;
~ I /1.(
, zl c::J
" )0f~(,
f Ii
~ <
150.00' [j]]] SAN MH UllJ
TC=911.60
1&:&]1 = Proposed Grade
- = Drainage Flow
XXX = Existing Grade"
Flood H!lZBrd Note:
Lot Number 14 lies within Zone .X. per the scaled location on
the Flood Insurance Rate Maps for Hamilton County, Indiana
(Community Panel #18057C0205F. dated February 19, 20(3).
Note:
This drav"ing is based upon construGl.ion plans andJor reoord
drawings prepared by others and Is not based upon a field survey.
COOR Consulting & Land Services, Corp. does not warrant the
correctness or integrtly of thIs information. The contractor/owner
should vertfy existing conditions prior ID construction. Any varying
field conditions or any discrepancy with the information oontained
hereon should be Immediately reported to COOR Consulting & Land
Services, Corp.; failure to do so would result in the contractor/owners
assumption of liability.
ercooro
@@IliJ@Q!]OllolliJ\ID ~ OOOIliJ@] f;')@Il'WO@@f;'),
@@D'Il"@D'iIDU~@1I'iI
303 WEST MAIN STREET KNIGHTSTOWN. INDIANA
(888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692
DATE: 01/23106 JOB #2004-250.014 REVISIONS:
Conc Flatwork Sq. Ft = :1:1736
Public Walk Sq Ft = :1:500
Sod Sq Yds = :t356
Seeding Sq Ft = :t8022
Note:
The proposed oonstruction grades depicted hereon are based upon
information, proposed grades and/or contours, taken from the
approved construction plans prepared for this subdivision. Unless
statad hereon. no information pertaining to but not limited to,
fluctuating water table elevations, soil types or conditions within the
building area of said lot, has been provided or referenced on said
plans. With the construction a a basement, it is recommended that
the lowest floor elevation be oonstructed at least two (2) feet above
any adjoining bodies of water unless a study of facts reveals
otherwise. Should any ground water be witnessed during the
excavation of said structure, the lowest floor elevation should be
raised at least two (2) teet above the ground water level and
additional construction techniques should be incorporated to
alleviate future problems.
LONGRIDGE ESTATES
SECTION ONE
PC 3, SUDE 729
lNSTR#200SOO063316
PLOT PLAN
Prepared For:
Cd~~
LOT # 14
13686 MONIQUE DRIVE
WESTFIELD, IN 46074
Pulte Homes of Indiana