HomeMy WebLinkAbout06010148-Site Plan
PARKVIEW - ELEV 2B
RIGHT HAND - Brick Ledge
PARTIAL BSMT - 9' Walls
3 CAR - Side Entry
WATER LINE
______sgfRRYLANf
TBM - B/lIV (29' BC-BC)
01.2 - -
SJL T FENCE
10.5'
2' CURB w'SSQ
100.27'
4'WAll(
".
CONe
ORNE
-
21.0' I
~
~
~
\-:
'>.,
-
30.0'
03.3
A K
22.6r
g
,
25.0'
THREE CAR
GAR
(UNEXC)
~
oi
1~~oJt.~
I
-----j
I
I
I
BSMT
I
102.31
I
I
PARKVIEW 28
(PART. BSMTJ
CRAWL
101~11
mi
-/
L03.3 J
21.71'
~
<ri
36.96'
~ PATIO
/
".
\
sr
or -SF-- c;r
10' DU&SE
Gr-
199.61
100.02'
BLOCK "A"
WATSON PARK
Flood Hazard Note:
Lot Number 111 lies within Zone "X" per the scaled location
on the Flood Insurance Rate Maps for Hamilton County,
Indiana (Community Panel #18057C0205F, dated February
19. 2003).
Note:
This drawing is based upon construction plans and/or record
drawings prepared by others and is nol based upon a field survey.
COQR Consulting & land Services, Corp. does nol warrant the
correctness or integrity of this inrormation. The contractor/owner
should verify existing conditions prior to construction. Any varying
field conditions or any discrepancy with the information contained
hereon should be immediately reported to COOR Consulting & Land
Services, Corp.; failure to do so would result in the contractor/owners
assumption of liability.
oor@
@@[Ji)@Q!]OIlO[Ji)(ID ~ O@)[Ji)@ @@[[WO@@@~
@@[J'[jD@[J'(ID(lo@1J'i)
303 WEST MAIN STREET KNIGHTSTOWN. INDIANA
(888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692
DATE: 01/03/06 JOB #2004-060.111 REVISIONS:
Gar. FFE = 903.3
1 sl Fir FFE = 905.1
Bsml FFE = 895.3
Drive Slope = 4.0%
SAN MH
TC=901.10 SAN SEWER
SAN MH
TC=900.80
I
~
I
; \
103.31
70.5'
Note:
&@@lliJ[1j'ft)@@] ~@D'lkDD
@@@)O@g '0" = ~@'
Note:
Min. Front Yard - 20'
Min. Side Yard - 5'
Min. Side Yard Aggregate - 15'
Min. Rear Yard - 20'
LOT # 111
+15,368 SF
MFFE 903.3 PER PLAN
I&K&I = Proposed Grade
--- = Drainage Flow
XXX = Existing Grade
Cone Flalwork Sq. Fl = :1:1850
Public Walk Sq Ft = :1:401
Sod Sq Yds = :1:287
Seeding Sq Ft = :1:8482
The proposed construction grades depicted hereon are based upon
information, proposed grades and/or contours, taken from the
approved construction plans prepared for this subdivision. Unless
stated hereon, no information pertaining to but not limited 10,
fluctuating water table elevations, soil types or conditions within the
building area of said lot, has been provided or referenced on said
plans. With the construction of a basement, it is recommended that
the lowest floor elevation be constructed at least two (2) feet above
any adjoining bodies of water unless a study of facts reveals
otherwise. Should any ground water be witnessed during the
excavation of said structure, the lowest floor elevation should be
raised at least two (2) feet above the ground water level and
additional construction techniques should be incorporated to
alleviate future problems.
LOT # 111
1825 DERRY LANE
CARMEL, IN 46032
PLOT PLAN
Prepared For:
II
II
1/ Contractor should verify site
1/ specific information depicted
" hereon with the approved
& ....""'fQ construction plans for this
~~c.. development.
~ I CI) II ~.. Note:
~ ! ~f7-
~ I II D:: /-;JS"-o:.
UJ
111m
I ~
~ III;;
g! II
~ ! II
! II
! II
III SSD
'i~8HMR::::T
TC=898.50
PAGE 1 OF 2
VILLAGE OF
WESTCLA Y
SECTION 9007
INSTR #200500042565
PC 3, SLIDE 665
~.
lp';ite:-
~~>>Jr?teV_ j
~r~~
Pulle Homes of Indiana