Loading...
HomeMy WebLinkAboutA015_FIFTH FLOOR LIFE SAFETY PLANDNDN A015 ARCHITECT CLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20010 APRIL 23, 2021THE SIGNATURECARMELCARMEL, INPERMIT SET ENGINEERFIFTH FLOORLIFE SAFETY PLANSCALE: 01 LIFE SAFETY PLAN FIFTH FLOOR 1/32" = 1'-0" NORTH B10 B4 A12 A6 A1 A1 A1 B1 A1 B3A1A1 B1 A2 A2 A2 A2 A2a A2a A2a A12 B9 S3 A8 A6 A2 A2 STAIR WIDTH = 48" DOOR WIDTH = 36" 240 STAIR WIDTH = 48" DOOR WIDTH = 36" 240 A1 R-2 723 SF4 200 1 B1 R-2 1065 SF6 200 1 A1 R-2 723 SF4 200 1 A1 R-2 723 SF4 200 1 A1 R-2 723 SF4 200 1 A6 R-2 664 SF4 200 1 B4 R-2 1239 SF7 200 1 A12 R-2 585 SF3 200 1 B10R-2 1095 SF6 200 1B1R-2 1065 SF6 2001A1R-2 723 SF4 200 1B3 R-2 1223 SF6 200 1 A8 R-2 1072 SF6 200 1 A6 R-2 664 SF4 200 1A2 R-2 867 SF5 200 1 A2 R-2 867 SF5 200 1 (151') (238') (141') (118) (125') 18 (198') 146 19 18 FEC FEC FECFECFEC A12 B9R-2 1123 SF6 200 1S3R-2 526 SF3 200 1A2 R-2 867 SF5 200 1 A2 R-2 867 SF5 200 1 A2a R-2 787 SF4 200 1 A2a R-2 787 SF4 200 1 A1R-2 723 SF4 200 1B3 R-2 1223 SF6 200 1 A12 R-2 585 SF 3 200 1 A12 R-2 585 SF 3 200 1 (75') (144')LEGEND: ROOM# B 451 SF46 100 1 31 34" 170 EXIT OCCUPANT LOAD THROUGH EXIT EGRESS WIDTH ALLOWABLE NUMBER OF OCCUPANTS THROUGH EXIT TRAVEL DISTANCE TO EXIT ACCESS OCCUPANCY GROUP ROOM ID ROOM AREA NUMBER OF EXITS REQUIRED OCCUPANT LOAD FACTOR NUMBER OF OCCUPANTS EGRESS CAPACITY OF STAIR SEMI-RECESSED OR SFC. MOUNTED FIRE EXTINGUISHER CABINET. REFERENCE DETAIL 5/A001.FEC 1-HOUR RATED ASSEMBLY 2-HOUR FIRE WALL LOAD FACTOR KEY A3 ASSEMBLY 15 NET R2 RESIDENTIAL 200 GROSS G GARAGE 200 GROSS B BUSINESS 100 GROSS S STORAGE 100 GROSS M MECH 300 GROSS MAX. TRAVEL DISTANCES AS LISTED IN IBC 2012 - SECTIONS 1014 & 1016 · COMMON PATH OF EGRESS TRAVEL - IBC 2012 TABLE 1014.3: OCCUPANCY TYPE R-2 - 125' WITH SPRINKLER SYSTEM · EXIT ACCESS - IBC 2012 TABLE 1016.2: OCCUPANCY TYPE R - 250' WITH SPRINKLER SYSTEM NON-RATED ASSEMBLY 2-HR FW 2-HOUR RATED ASSEMBLY FIRE EXSTINGUISHER CABINETFEC DIRECTION OF TRAVEL STAIR WIDTH = 48" DOOR WIDTH = 34" 240 GENERAL CODE NOTES 1. SEE COVER SHEET FOR APPLICABLE BUILDING CODE, OCCUPANCIES, AND CONSTRUCTION TYPES. 2. SEE O20 SERIES FOR SPECIFIC FLOOR, ROOF, AND WALL ASSEMBLY RATINGS AND CONSTRUCTION. 3. SEE OVERALL PLANS AND ENLARGED PLANS FOR WALL TYPE DESIGNATIONS. 4. SEE UNIT PLANS FOR WALL TYPE DESIGNATIONS IN APARTMENTS UNITS. 5. ALL DEMISING WALL BETWEEN ADJACENT UNITS AND BETWEEN UNITS & CORRIDORS TO BE 1-HOUR RATED. 6. ALL STAIR AND ELEVATOR SHAFTS TO BE 2-HOUR RATED. 7. WALLS BETWEEN AMENITIES AND ADJACENT APARTMENTS TO BE 1-HOUR RATED. 8. SEE INTERIOR WALL SECTIONS SHEET FOR DETAILS AT 1-HOUR AND 2-HOUR RATED ASSEMBLIES. A6 A6R-2 664 SF4 200 1A6 A6R-2 664 SF4 2001A6 A6R-2 664 SF4 2001A6 A6R-2 664 SF4 2001A6 A6 R-2 664 SF 4 200 1 A6 A6 R-2 664 SF4 200 1 A6 A6 R-2 664 SF4 200 1 A6 A6 R-2 664 SF4 200 1 GARAGE S2 29,200 SF146 200 2 1 PERMIT REVISION 08-04-2021 1 1 04/15/22