HomeMy WebLinkAboutA101-C_FIRST FLOOR BUILDING PLAN+5'-0" (857.00) +2'-0" (854.00) +1'-6" (853.50) +1'-6" (853.50) (853.00) +2'-0" (854.00) +2'-0" (854.00) UP UP UP +4'-0"(856.00) UP +2'-0"(854.00) +1'-0" (853.00)ARCHITECT CLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20010 APRIL 23, 2021THE SIGNATURECARMELCARMEL, INPERMIT SET ENGINEERGENERAL NOTES 1. THE GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AT THE JOBSITE. NOTIFY ARCHITECT OF ANY DEVIATIONS FROM THOSE CONDITIONS AS THEY ARE NOTED ON THE DRAWINGS. 2. THE GENERAL CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL WORK WITH THE OWNER. 3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL STATE AND LOCAL BUILDING CODES AND GOVERNMENT REGULATORY AGENCIES. 4. THE GENERAL CONTRACTOR IS TO SUBMIT SHOP DRAWINGS-PROJECT DATA AND SAMPLES TO OWNER/ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OF ALL MILLWORK AND WALL FINISHES. 5. DO NOT SCALE ANY DRAWING. ANY DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECT IF NOT NOTED ON THE DRAWINGS. REFER ALL QUESTIONS TO THE ARCHITECT OR ENGINEER ON RECORD. 6. ALL DIMENSIONS ARE TO C.L. OF DEMISING WALL OF UNITS AND FACE OF FRAMING. 7. THE GENERAL CONTRACTOR SHALL KEEP ONE SET OF PLANS AT THE JOBSITE FOR THE SPECIFIC PURPOSE OF RECORDING ACTUAL CONSTRUCTION CONDITIONS. SUCH PROJECT RECORD-DOCUMENTS SHALL BE PROVIDED TO THE OWNER UPON COMPLETION OF THE PROJECT. 8. THE GENERAL CONTRACTOR SHALL VERIFY SIZE, LOCATION, AND CHARACTERISTICS OF ALL WORKS AND EQUIPMENT SUPPLIED BY THE OWNER OR OTHERS WITH THE MANUFACTURER OR SUPPLIER PRIOR TO THE START OF THE WORK. 9. THE GENERAL CONTRACTOR SHALL SEE THAT ALL SUBCONTRACTORS RECEIVE COMPLETE WORKING DRAWINGS AND ASSUME FULL RESPONSIBILITY FOR COORDINATION OF WORK. 10. PRIMARY ENTRANCE DOOR NUMBERS CORRESPOND TO ROOM NUMBERS OR UNIT NUMBERS. PLAN KEY NOTES 1. 6" GALVANIZED TUBE STEEL BOLLARD FILLED WITH GROUT. PAINT IN FIELD. 2. STRUCTURAL STEEL LATERAL BRACING. SEE S SERIES SHEETS 3. CHASE TO ROOF ABOVE - TEMPORARILY CLOSE CHASE WITH RATED GYPSUM WLL BOARD ASSEMBLY UNTIL TENANT IS READY TO INSTALL DUCTWORK. 4. EXTENT OF CONCRETE SLAB WHILE SPACE IS IN SHELL CONDITION. 5. ELECTRIC METERS - SEE E SERIES SHEETS. 6. GALVANIZED 1-1/2" DIAMETER TUBE STEEL HANDRAIL. PAINT IN FIELD. 7. PAIR OF ELECTRIC WATER COOLERS - SEE P SERIES SHEETS 8. KONE MRL 2500 LB ELEVATOR 9. 3 YD DUMPSTERS BY OTHERS. 10. PROVIDE 1/2" PLYWOOD PANEL ON THREE WALLS FROM 3' TO 7' OVER GWB AND PAINT WHITE FOR MOUNTING ELECTRICAL PANELS. 11. ADA ACCESSIBLE 4C RECESSED MAIL BOXES - 310 MAIL BOXES. EACH UNIT SHOULD BE BLACK FINISH WITH 10 MAIL SLOTS, 1 OUTGOING, & 2 PACKAGE LOCKERS. 12. MOP SINK WITH 36" MOP AND BROOM HOLDER 13. PRINTER BY OWNER 14. GOLF SIMULATOR 15. U SHAPED BIKE LOOPS (MEET CARMEL CITY STANDARDS FOR SPACING AND CLEARANCES) 16. KONE MRL 4500 LB ELEVATOR 17. 1-1/2" DIAMETER TUBE STEEL RAMP HANDRAIL MOUNTED TO BLOCKING IN WALL. 18. FIRE EXTINGUISHER IN SEMI RECESSED CABINET WHEN IN STUD WALL, SURFACE MOUNTED ON PRECAST. 19. BIKE HANGERS SIMILAR TO VERTICALLY HANGING BIKE WALL RACK BY CYCLE SAFE - 124 COUNT 20. BIKE MAINTENANCE AREA - SIMILAR TO HUSKY 6 FT. ADJUSTABLE HEIGHTSOLID WOOD TOP WORKBENCH IN BLACK WITH PARK PCS-12.3 HOME MECHANICA BENCH MOUNT REPAIR STAND MOUNTED TO COUNTER 21. SHELVING BY OWNER 22. FAST ACTING ROLL UP DOOR SIMILAR TO OVERHEAD DOOR RAPIDGRILLE AP SECURITY GRILLE SYSTEM MODEL 676 WITH OPENING SPEED OF 50 IPS 23. ELECTRIC CAR CHARGING STATIONS. SEE E SERIES SHEETS 24. 18" X 24" FIRE RATED ACCES PANEL TO SHAFT 25. 4'-0" TALL BLACK CHAIN LINK FENCE WITH 2 GATES, 6'-0" TALL ACROSS NORTH SIDE OF COURT 26. PICKLEBALL COURT SURFACE - 2 COATS OF FORTIFIED ACRYLIC RESURFACER, 3 COATS OF FORTIFIED LAYKOLD COLOR CONCENTRATE WITH COURT MARKINGS. 27. ONE SET OF DOUGLAS PREMIER, BLACK PICKLEBALL NET POSTS IN SLEEVES WITH NET. 28. FOR MONUMENTAL STAIR DETAILS, REF A807 SHEET. 29. PROVIDE TEMPERED GLASS RAILING WITH MINIMAL BLACK STAINLESS STEEL HORIZONTAL CAP RAIL. GLASS PANELS SHOULD BE MOUNTED ON BLACK STAINLESS STEEL CRL RAIL BASE SHOE HARDWARE. REFERENCE STRUCTURAL DWGS FOR STEEL MOUNT SUBSTRATE DETAIL. 30. AT COLUMNS PROVIDE 12" METAL CHANNEL & TIGHT WRAP WITH GYP. BOARD. 31. PROVIDE DOG WASH STATIONS AT THIS LOCATION. UNIT TYPE APT # UNIT SHEET UNIT TAGS:* INDICATES METAL STUD CONSTRUCTION; SEE UNIT SHEET A101-CSCALE: 1 BUILDING PLAN - AREA C FIRST FLOOR 1/8" = 1'-0" AREA DAREA D AREA CAREA C AREA BAREA BAREA CAREA CELEC E102 UNIT A1* 146 A403 UNIT A1* 148 A403 UNIT A1* 150 A403 UNIT A1* 152 A403 UNIT A1* 154 A403 UNIT B4* 156 A421 UNIT A12* 158 A415 UNIT A1* 160 A403 UNIT A1* 162 A403 UNIT A1* 164 A403 UNIT A1* 166 A403 WATER W101 MAINTENANCE MA101 BIKE STORAGE B101 TRASH T102 NORTH 01 A207T102W101 31'-712"7'-0"31'-8" 70'-312"4'-718" 17'-314" 12'-8" 6'-11" 26'-434" 5'-4" 6'-212" 01/02 A205 02 A202 E102C102CORRIDOR C102 CORRIDOR C105 SFR W4 STAIR #1 ST1-1 STAIR & ELEVATOR LOBBY EL101 EL10101 A451 4'-1112" 4'-10" 3'-2" 4'-8" 3'-8" 3'-11" 4'-8" 3'-8" 3'-11" 3'-2" 4'-10" 5'-1" 4'-8"3'-8" 3'-11" 4'-8" 3'-8" 3'-11" 3'-2" 4'-10" 5'-1" 3'-2"4'-10"5'-1" 3'-2" 4'-10" 5'-1" 4'-414" 3'-8" 4'-234" 6'-534" 6'-614" 5'-812" 3'-8" 5'-6" 31'-8" 25'-4" ℄ - ℄ 25'-4" ℄ - ℄ 25'-4" ℄ - ℄ 25'-4" ℄ - ℄ 25'-4" ℄ - ℄ 11'-612" 169'-1012" 26'-1014" 7'-5"5'-858" 24'-0" 8'-1078" 31'-8" ST1-16'-1178" 12'-0" 1'-0" 1'-0" W4 W4 W4 W4 W8 W3 W3 W3 W3 W3 W3 W3 W3 W3 W3 W1 W1 5'-8"2'-8" 3'-8" 5'-8" 5'-812" 10'-8" 5'-10" 5'-1" 4'-10" 3'-2" 4'-812" 3'-8"3'-111116" 3'-1158"3'-8" 4'-858" 3'-2" 4'-10" 5'-1" 3'-2"4'-10" 5'-1" 4'-858" 3'-8"3'-1038" 4'-858" 3'-8" 3'-1038"3'-2" 4'-10" 5'-1"42'-4" 22'-4" ℄ - ℄ 25'-5316"℄ - ℄25'-5516"℄ - ℄25'-4"℄ - ℄25'-4"℄ - ℄166'-212"MA101F2101'-10" 32'-8"5'-1058" 60'-3"8'-258" 5'-334" W1 W1 W1 W1 W8 W8 W4 W3 W3 W3 W3 W3 W3 W3 W3 W4 W4 W4 FIRST FLOORBUILDING PLAN -AREA C01 A113 4'-278" 112"112"112"1'-0" 24'-0"MECH M103M103 3'-8"G101 ELEVATOR #1 WFC5A WFC5A WFC6 WFC6 WS4AWS4AWS4AWS3AWC1WC1 WS3A WS5A WS5A WS5A WS5A WS5A WS5A WC1 WC1 WC1 WB1AWB1A WB1A WB1A WS6AWS5AWS5AWS5AWS5AWS5AWS4A WS4A WS4A WS3A WS3A WS3A WM2WM3AWM2WM2WM2WE2WE2WE2WE2WE2WM2WM2 WM2 WM2 WM2 WM2 WM2 WM2 WM2 WM2 WM2 WFC6 WFC7WFC7WFC7 WFC7 WFC7 WFC7 WFC7WS1A WS3BWS1A WS5A WS5AWM3AWM3AWM3A WM2WFC7 WFC7WFC7 WM2WM2WFC7 WFC7 WFC7WM2WM2WM2WFC7 WFC7WFC7 WFC6 WM2WFC6WE2 WE2 WE2 WE2 6'-138" W1 3'-8"3'-8" 2'-8"3'-8" 3'-8" 3'-8" 3'-8"3'-8" W1 W1 2'-4"5'-0"5'-0" WS3B SFR SFE SFD G102 G103 EVENT CENTER CH101 CH101B CH101A SF4M107R105R103M104 R102 B101 SF5SF5SF5 SF5 M108 B104B103B102C10318 6 15 18 23 16 18 17 17 10 5 5 1 9 18 1 1 22 1 18 17 17 17 21 20 1 W12 W12 8'-918"8'-918"9'-858" 12'-1158" 15'-014" 16'-8" INDICATES UNIT TYPES TO BE CONSTRUCTED WITH METAL STUDS. 02 A352 02 A353 02 A353B101MA101A 03 A353 03 A351 TYP. 1 ADDENDUM #1 05-07-202124'-0"2 CONSTRUCTION ISSUE 07-08-2021 02 A353 3 PERMIT REVISION 08-04-2021 3 04/15/22