Loading...
HomeMy WebLinkAboutA103-D_THIRD FLOOR BUILDING PLANUP DNARCHITECT CLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20010 APRIL 23, 2021THE SIGNATURECARMELCARMEL, INPERMIT SET ENGINEERGENERAL NOTES 1. THE GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AT THE JOBSITE. NOTIFY ARCHITECT OF ANY DEVIATIONS FROM THOSE CONDITIONS AS THEY ARE NOTED ON THE DRAWINGS. 2. THE GENERAL CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL WORK WITH THE OWNER. 3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL STATE AND LOCAL BUILDING CODES AND GOVERNMENT REGULATORY AGENCIES. 4. THE GENERAL CONTRACTOR IS TO SUBMIT SHOP DRAWINGS-PROJECT DATA AND SAMPLES TO OWNER/ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OF ALL MILLWORK AND WALL FINISHES. 5. DO NOT SCALE ANY DRAWING. ANY DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECT IF NOT NOTED ON THE DRAWINGS. REFER ALL QUESTIONS TO THE ARCHITECT OR ENGINEER ON RECORD. 6. ALL DIMENSIONS ARE TO C.L. OF DEMISING WALL OF UNITS AND FACE OF FRAMING. 7. THE GENERAL CONTRACTOR SHALL KEEP ONE SET OF PLANS AT THE JOBSITE FOR THE SPECIFIC PURPOSE OF RECORDING ACTUAL CONSTRUCTION CONDITIONS. SUCH PROJECT RECORD-DOCUMENTS SHALL BE PROVIDED TO THE OWNER UPON COMPLETION OF THE PROJECT. 8. THE GENERAL CONTRACTOR SHALL VERIFY SIZE, LOCATION, AND CHARACTERISTICS OF ALL WORKS AND EQUIPMENT SUPPLIED BY THE OWNER OR OTHERS WITH THE MANUFACTURER OR SUPPLIER PRIOR TO THE START OF THE WORK. 9. THE GENERAL CONTRACTOR SHALL SEE THAT ALL SUBCONTRACTORS RECEIVE COMPLETE WORKING DRAWINGS AND ASSUME FULL RESPONSIBILITY FOR COORDINATION OF WORK. 10. PRIMARY ENTRANCE DOOR NUMBERS CORRESPOND TO ROOM NUMBERS OR UNIT NUMBERS. PLAN KEY NOTES 1. 6" GALVANIZED TUBE STEEL BOLLARD FILLED WITH GROUT. PAINT IN FIELD. 2. STRUCTURAL STEEL LATERAL BRACING. SEE S SERIES SHEETS 3. CHASE TO ROOF ABOVE - TEMPORARILY CLOSE CHASE WITH RATED GYPSUM WLL BOARD ASSEMBLY UNTIL TENANT IS READY TO INSTALL DUCTWORK. 4. EXTENT OF CONCRETE SLAB WHILE SPACE IS IN SHELL CONDITION. 5. ELECTRIC METERS - SEE E SERIES SHEETS. 6. GALVANIZED 1-1/2" DIAMETER TUBE STEEL HANDRAIL. PAINT IN FIELD. 7. PAIR OF ELECTRIC WATER COOLERS - SEE P SERIES SHEETS 8. KONE MRL 2500 LB ELEVATOR 9. 3 YD DUMPSTERS BY OTHERS. 10. PROVIDE 1/2" PLYWOOD PANEL ON THREE WALLS FROM 3' TO 7' OVER GWB AND PAINT WHITE FOR MOUNTING ELECTRICAL PANELS. 11. ADA ACCESSIBLE 4C RECESSED MAIL BOXES - 310 MAIL BOXES. EACH UNIT SHOULD BE BLACK FINISH WITH 10 MAIL SLOTS, 1 OUTGOING, & 2 PACKAGE LOCKERS. 12. MOP SINK WITH 36" MOP AND BROOM HOLDER 13. PRINTER BY OWNER 14. GOLF SIMULATOR 15. U SHAPED BIKE LOOPS (MEET CARMEL CITY STANDARDS FOR SPACING AND CLEARANCES) 16. KONE MRL 4500 LB ELEVATOR 17. 1-1/2" DIAMETER TUBE STEEL RAMP HANDRAIL MOUNTED TO BLOCKING IN WALL. 18. FIRE EXTINGUISHER IN SEMI RECESSED CABINET WHEN IN STUD WALL, SURFACE MOUNTED ON PRECAST. 19. BIKE HANGERS SIMILAR TO VERTICALLY HANGING BIKE WALL RACK BY CYCLE SAFE - 124 COUNT 20. BIKE MAINTENANCE AREA - SIMILAR TO HUSKY 6 FT. ADJUSTABLE HEIGHTSOLID WOOD TOP WORKBENCH IN BLACK WITH PARK PCS-12.3 HOME MECHANICA BENCH MOUNT REPAIR STAND MOUNTED TO COUNTER 21. SHELVING BY OWNER 22. FAST ACTING ROLL UP DOOR SIMILAR TO OVERHEAD DOOR RAPIDGRILLE AP SECURITY GRILLE SYSTEM MODEL 676 WITH OPENING SPEED OF 50 IPS 23. ELECTRIC CAR CHARGING STATIONS. SEE E SERIES SHEETS 24. 18" X 24" FIRE RATED ACCES PANEL TO SHAFT 25. 4'-0" TALL BLACK CHAIN LINK FENCE WITH 2 GATES, 6'-0" TALL ACROSS NORTH SIDE OF COURT 26. PICKLEBALL COURT SURFACE - 2 COATS OF FORTIFIED ACRYLIC RESURFACER, 3 COATS OF FORTIFIED LAYKOLD COLOR CONCENTRATE WITH COURT MARKINGS. 27. ONE SET OF DOUGLAS PREMIER, BLACK PICKLEBALL NET POSTS IN SLEEVES WITH NET. 28. FOR MONUMENTAL STAIR DETAILS, REF A807 SHEET. 29. PROVIDE TEMPERED GLASS RAILING WITH MINIMAL BLACK STAINLESS STEEL HORIZONTAL CAP RAIL. GLASS PANELS SHOULD BE MOUNTED ON BLACK STAINLESS STEEL CRL RAIL BASE SHOE HARDWARE. REFERENCE STRUCTURAL DWGS FOR STEEL MOUNT SUBSTRATE DETAIL. 30. AT COLUMNS PROVIDE 12" METAL CHANNEL & TIGHT WRAP WITH GYP. BOARD. 31. PROVIDE DOG WASH STATIONS AT THIS LOCATION. UNIT TYPE APT # UNIT SHEET UNIT TAGS:* INDICATES METAL STUD CONSTRUCTION; SEE UNIT SHEET A103-DTHIRD FLOORBUILDING PLAN -AREA DAREA DAREA D AREA CAREA C AREA EAREA E AREA DAREA D UNIT A2A 355 A405 UNIT A2A 357 A405 UNIT A2A 359 A405 UNIT A2 361 A404 UNIT A2 363 A404 UNIT A6 365 A409 UNIT A8 367 A411 UNIT B1 369 A417 UNIT A1 371 A403 UNIT A1 373 A403 UNIT B3 375 A420 UNIT A1 368 A403 UNIT A1 370 A403 UNIT A1 372 A403 UNIT A1 374 A403 UNIT A1 378 A403 UNIT B1 376 A417 MECH M304 CORRIDOR C303 CORRIDOR C304 CORRIDOR C305 CORRIDOR C303 SCALE: 01 BUILDING PLAN - AREA D THIRD FLOOR 1/8" = 1'-0" NORTH STAIR #2 ST2-3 STAIR & ELEVATOR LOBBY EL302ST2-3EL302B EL302A G302 F13M30403 A452 02 A206 5'-1" 4'-10" 3'-2" 4'-858" 3'-8" 3'-1038"4'-858" 3'-8" 3'-1038" 3'-2" 4'-10" 5'-1" 4'-8 5 8" 3'-8" 3'-1038" 4'-858" 3'-8" 3'-1038"3'-2" 4'-10" 5'-1" 3'-2" 4'-10" 5'-1" 2'-10" 3'-8" 3'-11" 4'-8 58" 3'-8" 8'-758" 3'-8" 4'-914"3'-1038"3'-8" 4'-858" 6'-312" 6'-312"25'-4"℄ - ℄25'-4"℄ - ℄25'-4"℄ - ℄25'-4"℄ - ℄35'-1012"℄ - ℄25'-514"℄ - ℄7'-6"3'-2" 3'-5"5'-4" 10'-8" 5'-11"5'-1" 5'-4" 2'-8" 4'-9" 3'-8" 3'-10" 3'-10" 4'-1112" 5'-4" 2'-8" 4'-9" 3'-8"162'-734"5'-312"3'-8" 7'-8" 3'-8" 5'-2" 4'-3116" 6'-10316" 25'-4"25'-4" ℄ - ℄ 25'-4" ℄ - ℄ 35'-1012" ℄ - ℄ 6'-10316" 118'-81116"5'-0"5'-958"2'-0"28'-0"6'-112" 3'-8" 6'-0" 3'-8" 6'-0" 3'-8" 6'-0" 3'-8" 6'-0" 25'-212" 25'-512"50'-8"4'-11"3'-1012"4'-134"5'-3" 5'-4"5'-4" 16'-112"6'-11516" 112"16'-114"℄ - ℄16'-114"℄ - ℄16'-0"℄ - ℄16'-0"℄ - ℄3'-8" 3'-8" 3'-8"3'-8" 4'-11"4'-9" 5'-11"5'-4" 5'-9" 4'-11" 714"112"4'-712" 714"4'-4"W2 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W8 W2 W2 W2 W1 W1 W2 W2W2 W2 W1W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W2 W1 W1 W1 W1 W1 W1 W1 W1 W2 W2 W2 W1 W1 W2 25'-4 5 8"4'-10 516 "8'-4" 4'-10 516"3'-8"3'-8" 16'-7"ELEVATOR #2 54'-7" 6'-1112" 123'-9" 6'-1112" 31'-8" 31'-212"7'-4" WG5AWG5AWG5AWG5AWG5AWG5BWG5BWG5B WG5B WG5B WG5BWG6BWG5BWG5B WG5AWG5AWG6AWG5AWG5AWG5AWG5A WG5A WG5A WG5A WG5B WG5B WG5B WG5B WC1 WG3A WG4A WG4A WG4B WG4A WG4A WG4A WG3A WG3A WG4B WG4B WG4B WG4B WG4B WG4A WG4B WG4A WG5A WG5AWG4AWG4AWG4AWG4BWG4BWG4BWC1WG3AWG4A WG4A WG4A WG4A WC1 WG3A WG3A WFC1 WFC1WM1 WM1 WM1 WM1 WM1 WM1 WM1 WM1 WM1 WM1 WE1 WE1 WE1 WE1 WE1 WE1 WE1 WFC3 WFC3WFC1WFC1WFC1 WFC1 WFC1 WFC1WFC1WFC1WFC1WFC1WM1WM1 WM1WM1 WFC1WFC1WFC1WFC1 WFC1 WFC1 WM1 WM1 WM1 WM1 WM1 WM1WM1 WM1 WM1 WM1 WFC1 WFC1 01 A203 02 A202 01 A205 02 A203 28'-0"5'-1012"7'-8" 3'-8" 6'-8" 3'-8" 6'-4" W1W1 W1 W1 18 18 IDF IT301 IT3018'-4516"8'-414" 03 A353 02 A351 02 A353 02 A353 02 A353 03 A351 TYP. 03 A352 07 A35118 3'-0"3'-0" 1'-6" 6'-0"+0"AFF +0"AFF +3"AFF +1-1/2" AFF +3"AFF WS3A WS3A1 ADDENDUM #1 05-07-2021 2 PERMIT REVISION 08-04-2021 2 04/15/22