HomeMy WebLinkAboutA411_ENLARGED UNIT A8 FLOOR PLANARCHITECT CLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20010
APRIL 23, 2021THE SIGNATURECARMELCARMEL, INPERMIT SET ENGINEER1. CONTRACTOR TO PROVIDE REQUIRED BLOCKING FOR CABINETS AND
BATH ACCESSORIES
2. ALL BEDROOM CLOSETS TO HAVE DOUBLE SHELF AND ROD
CONFIGURATION.
3. ALL COAT CLOSETS TO HAVE SINGLE SHELF AND ROD CONFIGURATION.
4. SEE MECHANICAL DRAWINGS FOR DRYER VENT INSTALLATION
LOCATION
5. SEE MECHANICAL DRAWINGS FOR IN-WALL WATER CONNECTIONS
6. CONTRACTOR TO VERIFY SIZE AND FRAMING DIMENSIONS OF HVAC
UNIT, BATHTUB, DOORS AND WINDOWS.
7. PROVIDE 1x2 PTD WOOD TRIM @ INTERIOR OF ALL CLOSETS / UTILITY
CLOSETS WHERE STANDARD DOOR CASING WILL NOT FIT.
8. UNDERCUT ALL INTERIOR DOORS FOR RETURN AIR 1".
9. ALL DRYWALL WET AREAS TO BE "GREEN" BOARD.
10. BASE OF MIRROR INSTALLED 40" AFF MAXIMUM.
11. PROVIDE DOOR VIEWER AT UNIT ENTRY DOORS
12. ALL CEILINGS ARE AT BOTTOM OF STRUCTURE (B.O.S.) IN UNITS U.N.O.
13. ALL FLOORING TRANSITIONS ARE TO BE CENTERED UNDER THE DOOR
14. REFER TO OVERALL PLANS FOR DEMISING / CORRIDOR WALL
REQUIREMENTS. ALL WALLS / WALL SECTIONS BEHIND PLUMBING
FIXTURES TO BE 2X6 MINIMUM. - FINISH WALLS TO ALIGN.
15. INTERIOR ELEVATIONS ARE FOR SCHEMATIC CABINET LAYOUT ONLY.
CONTRACTOR TO VERIFY ALL DIMENSIONS, PROVIDE FILLERS AS
REQUIRED. REFER TO CABINET SHOP DRAWINGS AND OWNER
SPECIFICATIONS.
UNIT PLAN NOTES
1
UNIT PLAN KEY NOTES
LOW VOLTAGE PANEL. SEE ELECTRICAL DRAWINGS.
ELECTRICAL LOADCENTER. SEE ELECTRICAL DRAWINGS.
ACRYLIC SHOWER SURROUND INSERT. SEE SPECIFICATIONS.
2
3
GENERAL NOTES
1. THE GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AT THE
JOBSITE. NOTIFY ARCHITECT OF ANY DEVIATIONS FROM THOSE
CONDITIONS AS THEY ARE NOTED ON THE DRAWINGS.
2. THE GENERAL CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL
WORK WITH THE OWNER.
3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH
ALL STATE AND LOCAL BUILDING CODES AND GOVERNMENT
REGULATORY AGENCIES.
4. THE GENERAL CONTRACTOR IS TO SUBMIT SHOP DRAWINGS-PROJECT
DATA AND SAMPLES TO OWNER/ARCHITECT FOR APPROVAL PRIOR
TO FABRICATION OF ALL MILLWORK AND WALL FINISHES.
5. DO NOT SCALE ANY DRAWING. ANY DIMENSIONS ARE TO BE
OBTAINED FROM THE ARCHITECT IF NOT NOTED ON THE DRAWINGS.
REFER ALL QUESTIONS TO THE ARCHITECT OR ENGINEER ON
RECORD.
6. ALL DIMENSIONS ARE TO C.L. OF DEMISING WALL OF UNITS AND FACE
OF FRAMING.
7. THE GENERAL CONTRACTOR SHALL KEEP ONE SET OF PLANS AT THE
JOBSITE FOR THE SPECIFIC PURPOSE OF RECORDING ACTUAL
CONSTRUCTION CONDITIONS. SUCH PROJECT RECORD-DOCUMENTS
SHALL BE PROVIDED TO THE OWNER UPON COMPLETION OF THE
PROJECT.
8. THE GENERAL CONTRACTOR SHALL VERIFY SIZE, LOCATION, AND
CHARACTERISTICS OF ALL WORKS AND EQUIPMENT SUPPLIED BY THE
OWNER OR OTHERS WITH THE MANUFACTURER OR SUPPLIER PRIOR
TO THE START OF THE WORK.
9. THE GENERAL CONTRACTOR SHALL SEE THAT ALL SUBCONTRACTORS
RECEIVE COMPLETE WORKING DRAWINGS AND ASSUME FULL
RESPONSIBILITY FOR COORDINATION OF WORK.
10. PRIMARY ENTRANCE DOOR NUMBERS CORRESPOND TO ROOM
NUMBERS OR UNIT NUMBERS.
FINISH PLAN NOTES
FLOOR TRANSITION.
ROOM SHOULD BE FINISHED W/ P1, LVT1 AND B1.
RUN FLOOR FINISH IN THE DIRECTION OF THE ARROW.
F2
F1
F3
WALL FINISH
FLOOR FINISH
WALL-BASE FINISH
MISC. FINISH
FINISH LEGEND
XX
XX
XX
XX
UNIT ACCESSORY NOTES
1. REFER TO A01X SHEET SERIES FOR MOUNTING HEIGHTS.
2. ALL UNIT ACCESSORIES TO BE MOUNTED INTO DRYWALL WITH
MANUFACTURER'S SPECIFIED ANCHORS.
3. ALL BATHROOM FIXTURES TO BE BRUSHED SATIN NICKLE U.N.O.
U1 MIRROR - FULL WIDTH
SURFACE MOUNTED TOILET TISSUE HOLDER
SHOWER ROD (CURTAINS BY OTHERS)
TOWEL HOOK
TOWEL BAR
U2
U3
U4
U5
SCALE:
02 REFLECTED CEILING PLAN
ENLARGED UNIT A8
1/4" = 1'-0" SCALE:
03 FINISH FLOOR PLAN
ENLARGED UNIT A8
1/4" = 1'-0" SCALE:
01 FLOOR PLAN
ENLARGED UNIT A8
1/4" = 1'-0"ENLARGED UNITA8 FLOORPLANSA411
W/D UTILITIES
BEDROOM
LIVING/DINING
KITCHEN
BATHROOM
B1
LVT1
P1
LIVING/DINING
KITCHEN
BATHROOM
ENTRY
U2 U1 U4
F2
U5
CLOSET
WG5aB1
LVT1
P1
BEDROOM
U3 U6
F2
D
W/D
UTILITIES
CLOSET
1
C
D
C
F
C
2
D WG1bWG1aWG1aWG1a
WG1a WG1bWG5b WG5a
WG5a
WG1a
DEN
D
A
D
WG3a
WG1bWG1aWG1a
WG1a
WG1a
WG1a WG4a
F1
B1
LVT1
P1
DEN
L1 L1
L1L1
A5
A5
L1 L1 L1
L1L1 L1
L1
L3
L1 L1
L6
L1
L1
6'-0"6'-0" 7'-914"7'-1034"4'
-
9
1 2
"8'-1"8'-1034"
4'-0" 4'-0" 2'-1034" 4'-512"6'-412"6'-434" 3'-10"
3'-912" 9'-912" 6'-0"2'-0"2'-014" 1'-6"2'-10"3'-7"3'-10" 1'-1034"
3'-614" 6'-814"3'-8"2'-234"2'-612"2'-612" 5'-8" 5'-8" 5'-614"
7'-512"2'-634"36'-714"312"1'-534"312" 3'-712" 512"5'-214" 812"312" 8'-414"4'-634" 7'-834" 5'-1034" 512"11'-114"
312"
3'-1012"
3 12"
7'-114" 3'-212"
312"7'-612"512"3'-512"4'-1"312"3'-1034"312"3'-3"312"3'-712"312"2'-1012"
13'-4"
1'
-
8
34"3
1 2
"3'
-1
1
1
2 "3 1
2"
1'
-
1
1
1
2"
25'-11"47'-1114"06
3'-8"3'-8"W/D UTILITIES
BEDROOM
LIVING/DINING
KITCHEN
BATHROOM
CLOSET
DEN
312"
WG3
34"
WG3
34" WG334"SCALE:
04 KITCHEN INTERIOR ELEVATION
1/2" = 1'-0"SCALE:
05 KITCHEN INTERIOR ELEVATION
1/2" = 1'-0"
MW1
HDW1
RANGE
AP1
WT1
MW
AP3
SS1
MW1
HDW1
PROVIDE 2 X 10 BLOCKING
OR EQUAL AT ALL UPPER
CABINETS
MW1
HDW1
3'-0" 1'-6" 1'-712" 1'-6" FILLER PANEL2'-0"6'-814"2'-1012"MW1
HDW1
SS1
DW
AP2
3'-0"
MW1
HDW1
AP4
REF.2'-1012" 2'-6"
SCALE:
06 BATHROOM INTERIOR ELEVATION
1/2" = 1'-0"
U2
SS2
MW1
HDW1
2'-6"
U1
2'-1012"1'-6"
2'-6"
F3
04
05
07
1'-6"
U3
1'-3" 2'-9"
2'-9" 2'-6" 2'-9"
SCALE:
06 BATHROOM INTERIOR ELEVATION
1/2" = 1'-0"
SS1
MW1
HDW1
2'-0"2'-1012"2'-9"
FILLER PANELFILLER PANEL
MW1
HDW1
ENTRY
04/15/22