HomeMy WebLinkAboutA411_ENLARGED UNIT A8 FLOOR PLANARCHITECT CLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20010 APRIL 23, 2021THE SIGNATURECARMELCARMEL, INPERMIT SET ENGINEER1. CONTRACTOR TO PROVIDE REQUIRED BLOCKING FOR CABINETS AND BATH ACCESSORIES 2. ALL BEDROOM CLOSETS TO HAVE DOUBLE SHELF AND ROD CONFIGURATION. 3. ALL COAT CLOSETS TO HAVE SINGLE SHELF AND ROD CONFIGURATION. 4. SEE MECHANICAL DRAWINGS FOR DRYER VENT INSTALLATION LOCATION 5. SEE MECHANICAL DRAWINGS FOR IN-WALL WATER CONNECTIONS 6. CONTRACTOR TO VERIFY SIZE AND FRAMING DIMENSIONS OF HVAC UNIT, BATHTUB, DOORS AND WINDOWS. 7. PROVIDE 1x2 PTD WOOD TRIM @ INTERIOR OF ALL CLOSETS / UTILITY CLOSETS WHERE STANDARD DOOR CASING WILL NOT FIT. 8. UNDERCUT ALL INTERIOR DOORS FOR RETURN AIR 1". 9. ALL DRYWALL WET AREAS TO BE "GREEN" BOARD. 10. BASE OF MIRROR INSTALLED 40" AFF MAXIMUM. 11. PROVIDE DOOR VIEWER AT UNIT ENTRY DOORS 12. ALL CEILINGS ARE AT BOTTOM OF STRUCTURE (B.O.S.) IN UNITS U.N.O. 13. ALL FLOORING TRANSITIONS ARE TO BE CENTERED UNDER THE DOOR 14. REFER TO OVERALL PLANS FOR DEMISING / CORRIDOR WALL REQUIREMENTS. ALL WALLS / WALL SECTIONS BEHIND PLUMBING FIXTURES TO BE 2X6 MINIMUM. - FINISH WALLS TO ALIGN. 15. INTERIOR ELEVATIONS ARE FOR SCHEMATIC CABINET LAYOUT ONLY. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROVIDE FILLERS AS REQUIRED. REFER TO CABINET SHOP DRAWINGS AND OWNER SPECIFICATIONS. UNIT PLAN NOTES 1 UNIT PLAN KEY NOTES LOW VOLTAGE PANEL. SEE ELECTRICAL DRAWINGS. ELECTRICAL LOADCENTER. SEE ELECTRICAL DRAWINGS. ACRYLIC SHOWER SURROUND INSERT. SEE SPECIFICATIONS. 2 3 GENERAL NOTES 1. THE GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AT THE JOBSITE. NOTIFY ARCHITECT OF ANY DEVIATIONS FROM THOSE CONDITIONS AS THEY ARE NOTED ON THE DRAWINGS. 2. THE GENERAL CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL WORK WITH THE OWNER. 3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL STATE AND LOCAL BUILDING CODES AND GOVERNMENT REGULATORY AGENCIES. 4. THE GENERAL CONTRACTOR IS TO SUBMIT SHOP DRAWINGS-PROJECT DATA AND SAMPLES TO OWNER/ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OF ALL MILLWORK AND WALL FINISHES. 5. DO NOT SCALE ANY DRAWING. ANY DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECT IF NOT NOTED ON THE DRAWINGS. REFER ALL QUESTIONS TO THE ARCHITECT OR ENGINEER ON RECORD. 6. ALL DIMENSIONS ARE TO C.L. OF DEMISING WALL OF UNITS AND FACE OF FRAMING. 7. THE GENERAL CONTRACTOR SHALL KEEP ONE SET OF PLANS AT THE JOBSITE FOR THE SPECIFIC PURPOSE OF RECORDING ACTUAL CONSTRUCTION CONDITIONS. SUCH PROJECT RECORD-DOCUMENTS SHALL BE PROVIDED TO THE OWNER UPON COMPLETION OF THE PROJECT. 8. THE GENERAL CONTRACTOR SHALL VERIFY SIZE, LOCATION, AND CHARACTERISTICS OF ALL WORKS AND EQUIPMENT SUPPLIED BY THE OWNER OR OTHERS WITH THE MANUFACTURER OR SUPPLIER PRIOR TO THE START OF THE WORK. 9. THE GENERAL CONTRACTOR SHALL SEE THAT ALL SUBCONTRACTORS RECEIVE COMPLETE WORKING DRAWINGS AND ASSUME FULL RESPONSIBILITY FOR COORDINATION OF WORK. 10. PRIMARY ENTRANCE DOOR NUMBERS CORRESPOND TO ROOM NUMBERS OR UNIT NUMBERS. FINISH PLAN NOTES FLOOR TRANSITION. ROOM SHOULD BE FINISHED W/ P1, LVT1 AND B1. RUN FLOOR FINISH IN THE DIRECTION OF THE ARROW. F2 F1 F3 WALL FINISH FLOOR FINISH WALL-BASE FINISH MISC. FINISH FINISH LEGEND XX XX XX XX UNIT ACCESSORY NOTES 1. REFER TO A01X SHEET SERIES FOR MOUNTING HEIGHTS. 2. ALL UNIT ACCESSORIES TO BE MOUNTED INTO DRYWALL WITH MANUFACTURER'S SPECIFIED ANCHORS. 3. ALL BATHROOM FIXTURES TO BE BRUSHED SATIN NICKLE U.N.O. U1 MIRROR - FULL WIDTH SURFACE MOUNTED TOILET TISSUE HOLDER SHOWER ROD (CURTAINS BY OTHERS) TOWEL HOOK TOWEL BAR U2 U3 U4 U5 SCALE: 02 REFLECTED CEILING PLAN ENLARGED UNIT A8 1/4" = 1'-0" SCALE: 03 FINISH FLOOR PLAN ENLARGED UNIT A8 1/4" = 1'-0" SCALE: 01 FLOOR PLAN ENLARGED UNIT A8 1/4" = 1'-0"ENLARGED UNITA8 FLOORPLANSA411 W/D UTILITIES BEDROOM LIVING/DINING KITCHEN BATHROOM B1 LVT1 P1 LIVING/DINING KITCHEN BATHROOM ENTRY U2 U1 U4 F2 U5 CLOSET WG5aB1 LVT1 P1 BEDROOM U3 U6 F2 D W/D UTILITIES CLOSET 1 C D C F C 2 D WG1bWG1aWG1aWG1a WG1a WG1bWG5b WG5a WG5a WG1a DEN D A D WG3a WG1bWG1aWG1a WG1a WG1a WG1a WG4a F1 B1 LVT1 P1 DEN L1 L1 L1L1 A5 A5 L1 L1 L1 L1L1 L1 L1 L3 L1 L1 L6 L1 L1 6'-0"6'-0" 7'-914"7'-1034"4' - 9 1 2 "8'-1"8'-1034" 4'-0" 4'-0" 2'-1034" 4'-512"6'-412"6'-434" 3'-10" 3'-912" 9'-912" 6'-0"2'-0"2'-014" 1'-6"2'-10"3'-7"3'-10" 1'-1034" 3'-614" 6'-814"3'-8"2'-234"2'-612"2'-612" 5'-8" 5'-8" 5'-614" 7'-512"2'-634"36'-714"312"1'-534"312" 3'-712" 512"5'-214" 812"312" 8'-414"4'-634" 7'-834" 5'-1034" 512"11'-114" 312" 3'-1012" 3 12" 7'-114" 3'-212" 312"7'-612"512"3'-512"4'-1"312"3'-1034"312"3'-3"312"3'-712"312"2'-1012" 13'-4" 1' - 8 34"3 1 2 "3' -1 1 1 2 "3 1 2" 1' - 1 1 1 2" 25'-11"47'-1114"06 3'-8"3'-8"W/D UTILITIES BEDROOM LIVING/DINING KITCHEN BATHROOM CLOSET DEN 312" WG3 34" WG3 34" WG334"SCALE: 04 KITCHEN INTERIOR ELEVATION 1/2" = 1'-0"SCALE: 05 KITCHEN INTERIOR ELEVATION 1/2" = 1'-0" MW1 HDW1 RANGE AP1 WT1 MW AP3 SS1 MW1 HDW1 PROVIDE 2 X 10 BLOCKING OR EQUAL AT ALL UPPER CABINETS MW1 HDW1 3'-0" 1'-6" 1'-712" 1'-6" FILLER PANEL2'-0"6'-814"2'-1012"MW1 HDW1 SS1 DW AP2 3'-0" MW1 HDW1 AP4 REF.2'-1012" 2'-6" SCALE: 06 BATHROOM INTERIOR ELEVATION 1/2" = 1'-0" U2 SS2 MW1 HDW1 2'-6" U1 2'-1012"1'-6" 2'-6" F3 04 05 07 1'-6" U3 1'-3" 2'-9" 2'-9" 2'-6" 2'-9" SCALE: 06 BATHROOM INTERIOR ELEVATION 1/2" = 1'-0" SS1 MW1 HDW1 2'-0"2'-1012"2'-9" FILLER PANELFILLER PANEL MW1 HDW1 ENTRY 04/15/22