Loading...
HomeMy WebLinkAboutA440_TYPICAL UNIT DETAILS-LT-A400CORRIDOR SIDE UNIT SIDE 1/2" RESILIENT CHANNEL. FASTENER MUST NOT COME IN CONTACT WITH WALL FRAMING. INSTALL LOWEST CHANNEL WITH STUD LEG UP; INSTALL ALL REMAINING CHANNELS WITH STUD LEG UP NON- HARDENING SEALANT SECTION VIEW EXTERIOR SIDE EXTERIOR WALL FINISH PLAN VIEW REF SHEET A022 FOR ADDITIONAL INTERIOR AND EXTERIOR WALL INFO. JOINT (TAPE AND COMPOUND) THE EXTERIOR WALL FINISH AND THE SHEATHING ARE THE ONLY SOLID WALL OR FLOOR ELEMENTS THAT BRIDGE THE SEPARATION BETWEEN DWELLING UNITS 24" MIN. SEAL DRYWALL TIGHT TO BASE AND FILL GAPS WITH TAPE AND MUD OR NON-HARDENING SEALANT NOTES: 1. LIGHT SWITCHES AND OUTLETS SHOULD BE OFFSET AT LEAST 24" AND BE LOCATED IN SEPARATE STUD CAVITIES. 2. SOUND ATTENUATION INSULATION SHOULD EXTEND BEHIND ELECTRICAL OUTLETS PLAN VIEW REF WG5 ON SHEET A022 FOR ADDITIONAL WALL INFO. PLAN VIEW REF WG5 ON SHEET A022 FOR ADDITIONAL WALL INFO. SEAL DRYWALL TIGHT TO BOX PENETRATION AND FILL GAPS WITH JOINT COMPOUND/MUD. USE JOINT REINFORCING TAPE AS NEEDED PLAN VIEW REF F1 ON SHEET A021 FOR ADDITIONAL FLOOR INFO. WATER CLOSET FILL THE GAP BETWEEN THE EDGES OF THE FLOOR PENETRATION AND THE WATER CLOSET FLANGE WITH AN APPROVED MEMBRANE PENETRATION FIRESTOP SYSTEM WATER CLOSETS TO BE RESILIENTLY MOUNTED WHEN SERVED BY DRAINS OR VENTS WHICH ARE INSTALLED WITHIN DEMISING ASSEMBLIES CORRIDOR SIDE UNIT SIDE SET RESILIENT CHANNELS ON EA. SIDE OF THE WALL WITH STUD LEG AS SHOWN AND MAX. 1.75 INCHES AWAY FROM WALL STUD, THEN CONTINUE INSTALLING THEM PER UL ASSEMBLY REQUIREMENTS NON- HARDENING SEALANT SECTION VIEW REF WG3 ON SHEET A022 FOR ADDITIONAL WALL INFO. REF F1 ON SHEET A021 FOR ADDITIONAL FLOOR INFO. JOINT (TAPE AND COMPOUND) AT BOTH SIDES OF WALL REF. FINISH DWGS SERIES A800's FOR BASE BOARD INFO. CORRIDOR SIDE UNIT SIDE PLAN VIEW REF SHEET A022 FOR ADDITIONAL INTERIOR AND EXTERIOR WALL INFO. JOINT (TAPE AND COMPOUND) EXTERIOR SIDE EXTERIOR WALL FINISH SECTION VIEW REF WG3 ON SHEET A022 FOR ADDITIONAL WALL INFO. REF F1 ON SHEET A021 FOR ADDITIONAL FLOOR INFO. JOINT (TAPE AND COMPOUND) AT BOTH SIDES OF WALL SET RESILIENT CHANNELS ON EA. SIDE OF THE WALL WITH STUD LEG AS SHOWN AND MAX. 1.75 INCHES AWAY FROM WALL STUD, THEN CONTINUE INSTALLING THEM PER UL ASSEMBLY REQUIREMENTS UNIT SIDEUNIT SIDE NON- HARDENING SEALANT PROVIDE 18" PERIMETER ISOLATION FOAM STRIP @ ALL UNIT WALL TO FLOOR INTERSECTIONS. CONTINUE TO FACE OF SILL PLATESECTION VIEW SHEATHING PER STRUCTURAL DWGS SOUND ISOLATION MAT ACOUSTIMAT 1 -@ VINYL FLOOR ONLY 34" CEMETITIOUS UNDERLAYMENT SCHEDULED FLOORING GAP UNDER BASE BOARD SCHEDULED BASE BOARD SHALL NOT CONTACT FLOORING. DO NOT APPLY SEALANT BETWEEN BASE AND FLOORING SCHEDULED WALL, REF. ENLARGED UNIT PLANS SECTION VIEW SHEATHING PER STRUCTURAL DWGS 3/4" CEMETITIOUS UNDERLAYMENT SCHEDULED FLOORING GAP UNDER BASE BOARD SCHEDULED BASE BOARD SHALL NOT CONTACT FLOORING. DO NOT APPLY SEALANT BETWEEN BASE AND FLOORING SCHEDULED WALL, REF. ENLARGED UNIT PLANS REF. FLOOR PLANS FOR WALL TYPES WRAP BOX (5 SIDES) WITH 58" TYPE 'X' GWB, TAPE ALL JOINTS SEMI-RECESSED FIRE EXTINGUISHER CABINET, RATING TO MATCH LABEL OF WALL 2 x WIDTH OF WALL FIRE BLOCKING, TYP. FLEXIBLE FLASHING (ON EXTERIOR SHEATHING) TOP STRAIGHT FLASHING OVER VERTICAL STRAIGHT FLASHING WALL PENETRATION. SEAL CONTINUOUS AROUND IT AND FINAL EXT. WALL FINISH VERT. STRAIGHT FLASHING OVER HRZ. BOTTOM STRAIGHT FLASHING SCALE: 01 AT DEMISING WALL TUB/SHOWER 1 1/2" = 1'-0"SCALE: 03 AT INTERIOR WALLS TUB/SHOWER 1 1/2" = 1'-0" SCALE: 02 AT CORRIDOR WALL TUB/SHOWER 1 1/2" = 1'-0" SCALE: 05 OF FIRE RATED WALL PLAN DETAIL AT INTERRUPTION 1 1/2" = 1'-0" WG4 WG5 58" TYPE 'X' GYPSUM WALL BOARD SHALL EXTEND TO FLOOR LEVEL 58" TYPE 'X' GYPSUM WALL BOARD SHALL EXTEND TO FLOOR LEVEL58" TYPE 'X' GYPSUM WALL BOARD SHALL EXTEND TO FLOOR LEVEL. 58" GYPSUM GREEN BOARD TO STOP AT TOP OF TUB OR SHOWER PAN W4NON-RATED PARTITION OR WALL PROVIDE CONT. FIRE RATED BLOCKING AT ALL POINTS WHERE A FIRE-RATED WALL OR PARTITION IS BEING INTERRUPTED BATHTUB / SHOWER SURROUND 58" GYPSUM GREEN BOARD TO STOP AT TOP OF TUB OR SHOWER PAN 58" GYPSUM GREEN BOARD TO STOP AT TOP OF TUB OR SHOWER PAN SCALE: 14 CHANNEL INSTALLATION RESILIENT FURRING 1 1/2" = 1'-0" SCALE: 08 AT DEMISING ASSEMBLY ELECTRICAL PENETRATION 1 1/2" = 1'-0" SCALE: 07 AT DEMISING ASSEMBLY PLUMBING PENETRATION 1 1/2" = 1'-0" SCALE: 06 AT DEMISING FLOOR ASSEMBLY PLUMBING PENETRATION 1 1/2" = 1'-0" SCALE: 12 ATTACHMENT TO CEILING AND FLOOR UNIT/CORRIDOR WALL 1 1/2" = 1'-0" SCALE: 10 WALL AND EXTERIOR WALL INTERSECTION UNIT/CORRIDOR 1 1/2" = 1'-0" SCALE: 09 AND EXTERIOR WALL INTERSECTION UNIT DEMISING WALL 1 1/2" = 1'-0" SCALE: 13 ATTACHMENT TO CEILING AND FLOOR DEMISING WALL 1 1/2" = 1'-0" SCALE: 18 FLOOR TO WALL CONNECTION TYPICAL VINYL PLANK 3" = 1'-0" BATHTUB / SHOWER SURROUND BATHTUB / SHOWER SURROUND SCALE: 16 SECTION DETAIL KITCHEN ISLAND 1 1/2" = 1'-0" SCALE: 17 FLOOR TO WALL CONNECTION TYPICAL CARPET 3" = 1'-0" 5'-112" FACE OF GWB 5'-014" FACE OF GREENBOARD 3'-8" FACE OF GWB 3'-63 4" FACE OF GREENBOARD STOP GREEN BOARD TUB/SHOWER SURROUND AT THE NEAREST CHANGE OF DIRECTION OF WALLS ON THE SHORT SIDE OF TUB/SHOWER CEILING OVER SHOWER AND TUB AREAS TO BE 58" TYPE 'C' GREENBOARD SCALE: 04 TUB / SHOWER PLAN DETAIL AT 1/2" = 1'-0" CEMENTITIOUS UNDERLAYMENT, 34" MIN. UNDER TUBS/SHOWERS AND IN DEAD AIR CAVITIES. THE SUBFLOORS MAY BE OVERLAID WITH EITHER 34" MIN. CEMENTITIOUS UNDERLAYMENT, 12" HOMASOTE BOARD, 1532" MIN. OSB OR PLYWOOD, OR 58" GP DENS GLASS SHELD FIRE GUARD TILE BACKER. SCALE: 11 DETAIL FIRE EXTINGUISHER 1 1/2" = 1'-0" SCALE: 19 PENETRATION DETAIL TYPICAL SEALANT @ 1 1/2" = 1'-0" WG1b WG4 (ABOVE TUB) SCHEDULED UNIT KITCHEN COUNTERTOP SCHEDULED UNIT BASE BOARD UNIT CASEWORK PER UNIT INTERIOR ELEVATIONS AND UNIT ENLARGED FLOOR PLANS WING WALL SUPPORT, PAINTED SEE PLAN A440TYPICAL UNITDETAILSWG1 RECEPTACLE AS NEEDED FOR APPLIANCES ARCHITECT CLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20010 APRIL 23, 2021THE SIGNATURECARMELCARMEL, INPERMIT SET ENGINEERSCALE: 15 FURRING DETAIL PRECAST COLUMN 1 1/2" = 1'-0" PRECAST CONCRETE COLUMN12"WS304/15/22