Loading...
HomeMy WebLinkAboutE100RETAIL 1 MC-A1MC-A2 MC-C2MC-B MC-D1 MC-D2 8 CONDUITS (3) MC-D1 (5) MC-D2 SA NOT IN SCOPE MC-C1 4 SA SA SA SA SA SA SA SA SA SA SA ELECTRICAL SITE SYMBOLS GENERAL SITE NOTES 1. VERIFY TRANSFORMER AND METERING LOCATIONS WITH DUKE ENERGY BEFORE INSTALL. 2. PROVIDE AND INSTALL CONDUIT FOR ELECTRICAL PRIMARY AND SECONDARY. VERIFY LOCATIONS WITH DUKE ENERGY BEFORE INSTALL. 3. PROVIDE AND INSTALL DUKE ENERGY PIT BOX PAD AT EACH TRANSFORMER LOCATION. VERIFY SPECIFICATIONS WITH DUKE ENERGY BEFORE INSTALL. 4. INSTALL 1" CONDUIT AND WIRING FOR POLE LIGHTS. VERIFY FINAL LOCATIONS BEFORE INSTALL. 5. install 1" conduit from building to pool house for wap low voltage wiring. PROPOSED POWER COMPANY TRANSFORMER LOCATION SINGLE HEAD POLE LIGHT PROPOSED METER CENTER LOCATION 1 WALL HEATER BY M.C., PROVIDE CIRCUIT AND CONNECTION. 2 EXHAUST FAN BY M.C., PROVIDE CIRCUIT, DISCONNECT (IF SHOWN) AND CONNECTION. CONTROL WIRING BY OTHERS. 3 PROVIDE CONDUIT AND WIRING FOR HP-7. FEED FROM MC-D2 4 PROVIDE 1" CONDUIT WITH PULL STRING FROM BUILDING TO JUNCTION BOX FOR FUTURE wall SIGN. VERIFY FINAL LOCATION WITH G.C. KEY SITE NOTES PROPOSED ELECTRICAL SECONDARY ROUTE PROPOSED ELECTRICAL primary ROUTE OC GG HP-7 J EH-4 1 3 J EF-4 2 WAP F1 F1 F1 ARCHITECT CLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS2OO1O april 23, 2o21THE SIGNATURECARMELCARMEL, INpermit SET ENGINEERSITEelectrical PLANE1OOSCALE: O1 ELECTRICAL PLAN SITE 1/32"= 1-O" NORTH MAIN STREETOLD MERIDIAN STREETRETAIL PLAZA POOL COURTYARD COURTYARD DOG PARK CONDO COURTYARD POOL EQUIPMENT BUILDING GARAGE SCALE: O2 ELECTRICAL PLAN POOL HOUSE 1/4" = 1'-O" 04/15/22