HomeMy WebLinkAboutE101-BGENERAL COMMON
AREA NOTES
1. ALL EXTERIOR LIGHTING CONTROLLED BY PHOTOCELL UNLESS
OTHERWISE NOTED.
2. VERIFY ALL EQUIPMENT REQUIREMENTS AND LOCATIONS WITH
INSTALLERS PRIOR TO ROUGH IN.
3. PROVIDE (1) 2OA 12OV gfci PROTECTED RECEPTACLE
WITHIN 25' OF ALL EXTERIOR MECHANICAL EQUIPMENT. USE
"IN-USE" STYLE WEATHER PROOF COVERS IDENTIFIED AS
"EXTRA-DUTY". USE EXTERIOR RATED RECEPTACLES.
4. EXHAUST FAN IN RESTROOMS BY M.C., PROVIDE WIRING AND
CONNECTION. POWER WITH LOCAL AREA SWITCHED LIGHTING
CIRCUIT.
1 HEATER BY M.C., PROVIDE CIRCUIT AND CONNECTION.
2 EXHAUST FAN BY M.C., PROVIDE CIRCUIT, DISCONNECT (IF
SHOWN) AND CONNECTION. CONTROL WIRING IF REQUIRED, BY
OTHERS.
3 24/7 EXHAUST FAN BY M.C., PROVIDE WIRING AND CONNECTION.
POWER WITH LOCAL AREA LIGHTING CIRCUIT.
4 ABOVE CEILING HEATER BY M.C., PROVIDE CIRCUIT,
DISCONNECT AND CONNECTION.
5 WATER HEATER BY M.C., PROVIDE CIRCUIT, DISCONNECT AND
CONNECTION.
6 FURNACE BY M.C., PROVIDE CIRCUIT, DISCONNECT (IF
REQUIRED) AND CONNECTION.
7 BOOSTER PUMP BY M.C., PROVIDE CIRCUIT, DISCONNECT (IF
REQUIRED) AND CONNECTION.
8 rtu by m.c., provide circuit, disconnect and connection.
9 a/c by m.c., provide circuit, disconnect and connection.
1o split unit by m.c., provide circuit, disconnect FOR
EXTERIOR UNIT and connections.
11 CEILING HEATER BY M.C., PROVIDE CIRCUIT, DISCONNECT AND
CONNECTION.
12 PROVIDE (2) CAT6 CABLE FROM NEAREST IT ROOM TO
ELEVATOR CONTROL BOX. VERIFY LOCATION WITH
ELEVATOR CONTRACTOR.
13 MAIN GARAGE ENTRY TYPE G LIGHT FIXTURES (4) ON DURING
DAYLIGHT HOURS ONLY. PROVIDE CONTROLLER FOR
OPERATION.
14 OVERHEAD DOOR BY OTHERS. PROVIDE CIRCUIT AND
CONNECTION. VERIFY NEEDS WITH OVERHEAD DOOR
CONTRACTOR.
15 CAR CHARGING STATION BY E.C., PROVIDE CIRCUIT, (1) CAT6
FROM NEAREST IT ROOM AND CONNECTION.
16 FUTURE CAR CHARGING STATION. PROVIDE CIRCUIT AND (1)
CAT6 FROM NEAREST IT ROOM, IN JUNCTION BOXES.
17 provide gfci protected circuit for drinking
fountains. verify requirements with installer.
18 SIGN BY OTHERS. PROVIDE CIRCUIT AND DISCONNECT (IF
REQUIRED). verify requirements with installer.
19 PROVISION FOR IRRIGATION. VERIFY FINAL LOCATIONS WITH
IRRIGATION CONTRACTOR.
2O provide power and (1) CAT6 for VEHICLE VACUUM STATION.
VERIFY FINAL LOCATION AND NEEDS WITH G.C.
21 provide power and data for door intercom. (1) CAT6,
(1) 18-2 AND (1) 16-2, 14-2 OR 12-2 DEPENDING ON DISTANCE.
(1OO', 18O'AND 3OO' RESPECTIVELY). VERIFY REQUIREMENTS
WITH INSTALLER.
22 PROVIDE and install heating green home yoga heating
package for 1oosf in HOT YOGA ROOM. VERIFY final
location WITH G.C.
23 for mdf room provide (2) dedicated quad receptacle,
(2) 4x8 sheet of fire rated plywood, (1) terminal strip
with #6 copper conductor from electrical system for
intersystem bonding and (2) 4" conduit with pull string
to exterior service location.
24 for idf room provide (2) dedicated quad
receptacle, (1) 4x8 sheet of fire rated plywood, (1)
terminal strip with #6 copper conductor from
electrical system for intersystem bonding.
interconnect mdf ROOM to each idf room with 6-strand
multi-mode fiber.
KEY COMMON AREA NOTES
s S
s S
s S
OS
OS
HS
HS
HS
F
F
EWH-1OC OC OCGF-2
EF-6
7
JEF-3
2
F
J EH-1
1
A
F1
F1
G D1 OCOC
HP-1HP-2sH
sH
G
F
G
s S s S s S s S
HS
HS
HS
OC
6
D
F1
F1
F1
s Ss S OCs S
FHS
s S
s S
s S
s S
HS
S
G
LF28 OC
S
G
LF28
HS OCOC
S OC
S OC
S
OS
F
HS
HS
HS
F1F1
S
S
S
OSRD
D OCS
HS
WP
BB B B
BB B B B B
s Ss S s S s S
OS
OS
HSHS HS
A A A
A
A A A A A A A A A A A AOS OS OS OSs S s S
HS
A
A A FACP
HS
WP
ANNs S
GF-2
GF-3
6
6
EF-1 EF-1
GF-1
6
J
EF-2 3
J EF-9
3
BP-1
J
EH-2
1
MC-A2 MC-A1 RETAIL 1
CR
CR
CR
17
s S
19
WP/G
19
WP/G
19
WP/G
21
OCS
@46" @46" @46" @46"
WAP
WAP
WAP
LF1OW LF1OW LF1OWLF1OW
LF1OWLF1OW LF1OW LF1OW
LF1OW LF1OW LF1OWLF1OW
LF1OW LF1OW LF1OW LF1OW
LF1OW LF1OW LF1OWLF1OW
LF1OW LF1OW LF1OW LF1OW
LF1OW LF1OW LF1OWLF1OW
LF1OW LF1OW LF1OW LF1OW
LF1OW LF1OW LF1OWLF1OW
LF1OW LF1OW LF1OW LF1OW
LF1OW LF1OW LF1OWLF1OW
LF1OWLF1OW LF1OW LF1OW
LF1OW LF1OW LF1OW LF1OW LF1OW LF1OWLF1OW LF1OW LF1OW LF1OWLF1OW LF1OW LF1OW LF1OWLF1OW
LF1OW
LF1OW
LF1OW
LF1OW LF1OW
LF1OW LF1OW
LF1OW
LF1OW LF1OW
LF1OW LF1OW
LF1OW LF1OW
LF1OW LF1OW
LF1OW LF1OW
LF1OW LF1OW
LF1OW LF1OW
LF1OW
LF12 LF12 LF12
LF12 LF12
LF12
LF12 LF12 LF12
LF12LF12 LF12
LF12 LF12 LF12LF12LF12
LF14 LF14 LF14 LF14
LF14 LF14 LF14 LF14
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW LF1OW
LF1OW
LF1OW
LF1OW LF1OW
LF1OW
LF1OW
LF1OW LF1OW
LF1OW
LF1OW
LF1OW LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OWLF1OW LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OWLF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW LF1OW LF1OW
LF1OW
LF1OW LF1OW
LF1OW
LF16 LF16 LF16 LF16 LF16
LF21
LF21
LF21
LF21 LF1OW
LF1OW LF1OW LF1OW LF1OW
LF1OWLF1OW LF1OW
LF15 LF15
LF1OW LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF1OW
LF13
LF13
LF11
LF11
LF11
LF11
LF11 LF11 LF11 LF11 LF11LF11
A
F1
F1
F1
F1
F1
F1
F1
F1
F1 OCOC S S
HS
s S
TV
TV TV TV TV
TV
@46"
X2
X2
CBWAPWAPF2
F2F2
F2
OS
OS
WAP WAP
WAP
WAP
WAP WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP WAP
WAP
WAP
WAP
X2
X2
1OS
OS
OS 1 1 1 1
OS
OS
s S
s S sSX2
X2
TS
TS
FS
J
22
DH 23
D
PC
OS ARCHITECT CLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS2OO1O
april 23, 2o21THE SIGNATURECARMELCARMEL, INpermit SET ENGINEERSCALE:
O1 SELECTRICAL PLAN - AREA B
FIRST FLOOR
1/8" = 1'-O"
NORTH first floorelectrical planarea bE1O1-b
B
C
E
AAREA BAREA BAREA CAREA CAREA BAREA B
AREA AAREA A
D
1
E5O2
1
E5O1
04/15/22