Loading...
HomeMy WebLinkAbout2021-08-12_FireDeptResponse2 West Main Street, Carmel, IN 46032 317.810.1502 www.studiomarchitecture.net PLAN REVIEW COMMENTs & RESPONSES Carmel Fire Department Project Name: The Signature Carmel - Garage Architectural Project Number: 20010 Date: 13 August 2021 Mr. Ellison – thank you for your review of the project. Please see your plan review comments and our responses below. 1. Comment: IFC 3313.1 Where required. In buildings required to have standpipes by Section 905.3.1, not less than one standpipe shall be provided for use during construction. Such standpipes shall be installed when the progress of construction is not more than 40 feet (12 192 mm) in height above the lowest level of fire department vehicle access. Such standpipe shall be provided with fire department hose connections at accessible locations adjacent to usable stairs. Such standpipes shall be extended as construction progresses to within one floor of the highest point of construction having secured decking or flooring. Response: Standpipes will be part of the subcontractors design scope. Standpipes will be designed and installed per code and drawings provided for approval. 2. Comment: IFC 1008.1.2 Doors shall swing in the direction of egress travel where serving a room or area containing an occupant load of 50 or more persons. The required exit door at the NW garage lobby shall swing in the direction of egress travel. Response: Door has been added from stair at NW corner of garage to provide more direct access to the exit. 3. Comment: The required exiting fire resistive rating shall be maintained at all garage lobby and garage exiting areas for the R occupancy occupants. Several locations where residential occupants must exit through garage lobby locations do not maintain the required fire resistive rating. IFC 1018.6 Response: Stair lobbies have been revised to be 2 HR rated so the egress path rating is maintained. Exit signs on east residential corridor are removed from electrical drawings. 4. Comment: As we discussed, code compliant exiting must be maintained at all times from the 1st floor exit corridor through the leasing office as currently proposed. Under the rules of the IFC, obstructing or restricting of this exit location is not permitted. Response: This door is to remain unlocked and free to pass for residents at all times. 5. Comment: The garage interior stairs exiting at grade level need revised to comply with the exit discharge rules established in section 1027 if the IFC. Response: Exit sign is provided at double doors and at exterior door to clearly mark the egress path when leaving the lobby area. No other equipment, furniture 04/15/22 2 West Main Street, Carmel, IN 46032 317.810.1502 www.studiomarchitecture.net or anything which may be an obstruction is planned for the space between the egress doors from the lobby to the exterior door. 6. Comment: A Standpipe system shall be installed as required by section 905 of the Indiana Fire Code. Hose valve connections shall be installed at each required location as identified by section IFC 905.4. Plans for the standpipe system shall be submitted for review by CFD. Response: Standpipes will be part of the subcontractors design scope. Standpipes will be installed per code and drawings provided for approval. 7. Comment: Single Station Smoke Alarms shall be installed as required by the section 907.2.11 of the Indiana Fire Code. Response: Fire alarm system will be part of the subcontractors design scope. Alarms will be designed and installed per code and drawings provided for approval. 8. Comment: Per section 3002.4 of the Indiana Building Code, Provide confirmation the elevators in the buildings can accommodate an ambulance cot. Response: This will be provided when the elevator manufacturer and model is finalized. The current basis for design for elevator #1 is a 4500# service elevator. 9. Comment: Any Electronic locking system shall be installed as required by the Indiana Fire Code. Response: The access control system will be in compliance with the Fire Code as required. 10. Comment: Please submit fire alarm and fire sprinkler plans to CFD once available. Response: Fire sprinkler and fire alarm drawings will be submitted to CFD. If you have any further questions regarding these responses or the revisions to the drawings, please contact me via email or phone. Thank you, Michael Johnson, RA Project Manager 04/15/22