HomeMy WebLinkAboutA051 - WINDOW SCHEDULE AND DETAILSW1 2'-0" 3'-0"6'-0"6'-0"6'-0"2'-0" 3'-0" 3'-0" SINGLE HUNG, FIBERGLASS W2 (2) SINGLE HUNG, FIBERGLASS W3 (3) SINGLE HUNG, FIBERGLASS 9'-0"6'-0"2'-0" 3'-0" 3'-0"3'-0" W6 (3) SINGLE HUNG WITH TRANSOM, FIBERGLASS 9'-0"6'-0" 2'-0" 3'-0" 3'-0"3'-0"2'-0"8'-0"W4 2'-0" 3'-0"6'-0" 6'-0"6'-0" 2'-0" 3'-0" 3'-0" (1) SINGLE HUNG WITH TRANSOM, FIBERGLASS W5 (2) SINGLE HUNG WITH TRANSOM, FIBERGLASS 2'-0"8'-0"2'-0"8'-0"5'-0"6'-0"2'-0" 2'-6" 2'-6" W2b (2) SINGLE HUNG, FIBERGLASS TYP. BRICK TRIM PROFILE ARCHITECTCLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031 JANUARY 15, 2021 # DESCRIPTION DATENORTH ENDMULTIFAMILYCARMEL, INDIANABID DOCUMENTS GC/CM NOTE: ALL WINDOWS THAT ARE LESS THAN 18 INCHES FROM DOORS ARE TO RECEIVED TEMPERED GLASS.WINDOW SCHEDULEAND DETAILSA051 BRICK SOLDIER COURSE SCHEDULE WINDOW BRICK ROWLOCK SILL WINDOW ASSEMBLY SHIM BY WINDOW INSTALLER MORTAR NET BACKER ROD AND CONTINUOUS SEALANT WRAP AND FLASH WEATHER MEMBRANE AROUND OPENING AS RECOMMENDED BY WEATHER MEMBRANE MFR. CONTINUOUS SELF ADHERING MEMBRANE OVER LOOSE LINTEL AND STAINLESS STEEL DRIP EDGE SCALE: H1 AT MASONRY HEAD WINDOW 3" = 1'-0" LOOSE STEEL LINTEL PRIMED AND PAINTED STAINLESS STEEL DRIP EDGE BRICK WEEP BRICK SOLDIER COURSE RETURN GWB AT JAMB CONT. SEALANT SPRAY FOAM CONTINUOUS SELF-ADHERING MEMBRANE PRIOR TO WINDOW AND W.R.B. INSTALLATION REF. STRUCTURAL DWGS. FOR HEADER INFO. SCALE: J1 AT MASONRY JAMB WINDOW 3" = 1'-0" 1" CONTINUOUS SELF ADHERING MEMBRANE FROM INSIDE. SEALANT BETWEEN MOUNTING FLANGE & W.R.B. AND BETWEEN MOUNTING FLANGE & FLEXIBLE FLASHING SHIM BY WINDOW INSTALLER WINDOW AS SCHEDULED SHIM BY WINDOW INSTALLER WINDOW AS SCHEDULED WEATHER MEMBRANE OVER WINDOW NAILING FLANGE CONT. SEALANT PAINTED 1x WOOD SILL CONTINUOUS SELF-ADHERING MEMBRANE, FROM 1" MIN. DOWN INSIDE FACE OF WALL, UP & OVER SILL PLATE, AND & OVER EXTERIOR BUILDING WRAP 6" MIN. 2X WOOD TOP PLATE 1x4 WOOD TRIM 2X WOOD TOP PLATE, SEE STRUCTURAL DRAWINGS CONTINUOUS SEALANT SPRAY FOAM SCALE: S1 AT MASONRY SILL WINDOW 3" = 1'-0" BRICK ROWLOCK SILL BRICK WEEP MORTAR NET STAINLESS STEEL DRIP EDGE BACKER ROD AND CONTINUOUS SEALANT CONTINUOUS SELF ADHERING MEMBRANE FLASHING 2X WOOD STUDS, SEE STRUCTURAL DRAWINGS RETURN GWB AT JAMB CONT. SEALANT SPRAY FOAM CONTINUOUS SELF-ADHERING MEMBRANE PRIOR TO WINDOW AND W.R.B. INSTALLATION CONTINUOUS SELF ADHERING MEMBRANE OVER WINDOW FLANGE, SEALANT BETWEEN MOUNTING FLANGE & W.R.B. AND BETWEEN MOUNTING FLANGE & FLEXIBLE FLASHING BRICK WEEP SCALE: J2 METAL PANEL JAMB WINDOW AT 3" = 1'-0" SHIM BY WINDOW INSTALLER WINDOW AS SCHEDULED 2X WOOD STUDS, SEE STRUCTURAL DRAWINGS RETURN GWB AT JAMB CONT. SEALANT SHIM BY WINDOW INSTALLER WINDOW AS SCHEDULED CONT. SEALANT CONTINUOUS SELF ADHERING MEMBRANE FROM INSIDE SEALANT BETWEEN MOUNTING FLANGE & W.R.B. AND BETWEEN MOUNTING FLANGE & FLEXIBLE FLASHING PAINTED 1x WOOD SILL 1" CONTINUOUS SELF-ADHERING MEMBRANE, FROM 1" MIN. DOWN INSIDE FACE OF WALL, UP & OVER SILL PLATE, AND & OVER EXTERIOR BUILDING WRAP 6" MIN. 2X WOOD TOP PLATE 1x4 WOOD TRIM 2X WOOD TOP PLATE, SEE STRUCTURAL DRAWINGS BACKER ROD AND CONTINUOUS SEALANT WEATHER MEMBRANE OVER WINDOW NAILING FLANGE CONTINUOS SEALANT (AND BACKER ROD IF NECESSARY) CONTINUOUS SELF ADHERING MEMBRANE OVER WINDOW FLANGE SEALANT BETWEEN MOUNTING FLANGE & W.R.B. AND BETWEEN MOUNTING FLANGE & FLEXIBLE FLASHING SPRAY FOAM SPRAY FOAM SCALE: S2 METAL PANEL SILL WINDOW AT 3" = 1'-0" SCALE: H2 METAL PANEL HEAD WINDOW AT 3" = 1'-0" SCALE: 01 WINDOW SCHEDULE 1/4" = 1'-0" METAL PANEL SYSTEM J-TRIM / FINISHING CAP METAL PANEL SYSTEM J-TRIM / FINISHING CAP SHIM BY WINDOW INSTALLER WINDOW AS SCHEDULED 2X WOOD STUDS, SEE STRUCTURAL DRAWINGS RETURN GWB AT JAMB CONT. SEALANT WEATHER MEMBRANE OVER WINDOW NAILING FLANGE CONTINUOS SEALANT (AND BACKER ROD IF NECESSARY) CONTINUOUS SELF ADHERING MEMBRANE OVER WINDOW FLANGE SEALANT BETWEEN MOUNTING FLANGE & W.R.B. AND BETWEEN MOUNTING FLANGE & FLEXIBLE FLASHING SPRAY FOAM METAL PANEL SYSTEM J-TRIM / FINISHING CAP SCALE: J3 AT LAP SIDING JAMB WINDOW DETAILS 3" = 1'-0" REF. STRUCTURAL DWGS. FOR HEADER INFO. SHIM BY WINDOW INSTALLER WINDOW AS SCHEDULED CONT. SEALANT PAINTED 1x WOOD SILL CONTINUOUS SELF-ADHERING MEMBRANE, FROM 1" MIN. DOWN INSIDE FACE OF WALL, UP & OVER SILL PLATE, AND & OVER EXTERIOR BUILDING WRAP 6" MIN. 2X WOOD TOP PLATE SHIM BY WINDOW INSTALLER WINDOW AS SCHEDULED 2X WOOD STUDS, SEE STRUCTURAL DRAWINGS RETURN GWB AT JAMB CONT. SEALANT RETURN GWB AT JAMB CONT. SEALANT WRAP AND FLASH WEATHER MEMBRANE AROUND OPENING AS RECOMMENDED BY WEATHER MEMBRANE MFR. SEALANT BETWEEN MOUNTING FLANGE & W.R.B. AND BETWEEN MOUNTING FLANGE & FLEXIBLE FLASHING CONTINUOUS SELF ADHERING MEMBRANE, LAP OVER WINDOW NAILING FLANGE CONTINUOUS SELF ADHERING MEMBRANE FROM INSIDE SEALANT BETWEEN MOUNTING FLANGE & W.R.B. AND BETWEEN MOUNTING FLANGE & FLEXIBLE FLASHING CONTINUOUS SELF ADHERING MEMBRANE OVER WINDOW FLANGE SEALANT BETWEEN MOUNTING FLANGE & W.R.B. AND BETWEEN MOUNTING FLANGE AND FLEXIBLE FLASHING 1x4 WOOD TRIM 1" 2X WOOD TOP PLATE, SEE STRUCTURAL DRAWINGS714"5/4 FIBER CEMENT TRIM BOARD ON 3/8" FIBER CEMENT BACKER BOARD KICK-OUT FLASHING, EXTEND VERT. LEG UP FACE OF SHEATHING MIN. 5 INCES CONTINUOS SEALANT (AND BACKER ROD IF NECESSARY) CONTINUOS SEALANT 5/4 FIBER CEMENT TRIM BOARD ON 3/8" FIBER CEMENT BACKER BOARD 312" 5/4 FIBER CEMENT TRIM BOARD ON 3/8" FIBER CEMENT BACKER BOARD CONT. SEALANT CONTINUOS SEALANT (AND BACKER ROD IF NECESSARY)312"WEATHER MEMBRANE OVER WINDOW NAILING FLANGE SPRAY FOAM SPRAY FOAM SPRAY FOAM SCALE: S3 AT LAP SIDING SILL WINDOW DETAILS 3" = 1'-0" SCALE: H3 AT LAP SIDING HEAD WINDOW DETAILS 3" = 1'-0" WINDOW ASSEMBLY SHIM BY WINDOW INSTALLER CORROSIVE RESISTANT HEAD FLASHING, SET IN SEALANT SCALE: H4 AT MASONRY HEAD WINDOW DETAILS 3" = 1'-0" WINDOW ASSEMBLY SHIM BY WINDOW INSTALLER WRAP AND FLASH WEATHER MEMBRANE AROUND OPENING AS RECOMMENDED BY WEATHER MEMBRANE MFR. SPRAY FOAM 8" BOND BEAM: SEE STRUCTURAL DWGS 1X WOOD TRIM NOMINAL 8" CMU: SEE STRUCTURAL DWGS FOR GROUT & REINFORCING SCALE: S4 AT MASONRY SILL WINDOW DETAILS 3" = 1'-0" SHIM BY WINDOW INSTALLER WINDOW AS SCHEDULED BACKER ROD AND CONTINUOUS SEALANT NOMINAL 8" CMU: SEE STRUCTURAL DWGS FOR GROUT & REINFORCING NOMINAL 8" CMU GROUT FULL PAINTED 1x WOOD SILL 1x WOOD TRIM CONTINUOUS SEALANT CONTINUOUS SELF-ADHERING MEMBRANE, FROM 1" MIN. DOWN INSIDE FACE OF WALL, UP & OVER SILL PLATE, AND & OVER EXTERIOR BUILDING WRAP 6" MIN. 2X WOOD TOP PLATE CONTINUOUS SEALANT CONTINUOUS SEALANT SCALE: J4 AT MASONRY JAMB WINDOW DETAILS 3" = 1'-0" SHIM BY WINDOW INSTALLER WINDOW AS SCHEDULED CONTINUOUS SEALANT CONTINUOUS SELF ADHERING MEMBRANE OVER WINDOW FLANGE, SEALANT BETWEEN MOUNTING FLANGE & W.R.B. AND BETWEEN MOUNTING FLANGE & FLEXIBLE FLASHING WEATHER MEMBRANE OVER WINDOW NAILING FLANGE NOMINAL 8" CMU: SEE STRUCTURAL DWGS FOR GROUT & REINFORCING CONTINUOUS SEALANT 1x4 WOOD TRIM CONTINUOUS SEALANT CONTINUOUS SEALANT 1" PAINTED WOOD SILL714"KICK-OUT FLASHING, EXTEND VERT. LEG UP FACE OF SHEATHING MIN. 5 INCES 5/4 FIBER CEMENT TRIM BOARD ON 3/8" FIBER CEMENT BACKER BOARD CONTINUOUS SELF ADHERING MEMBRANE, LAP OVER WINDOW NAILING FLANGE CORROSIVE RESISTANT HEAD FLASHING, SET IN SEALANT CONTINUOUS SELF ADHERING MEMBRANE FROM INSIDE SEALANT BETWEEN MOUNTING FLANGE & W.R.B. AND BETWEEN MOUNTING FLANGE & FLEXIBLE FLASHING CONTINUOS SEALANT (AND BACKER ROD IF NECESSARY)312"04/15/22