HomeMy WebLinkAboutA051 - WINDOW SCHEDULE AND DETAILSW1 2'-0" 3'-0"6'-0"6'-0"6'-0"2'-0" 3'-0" 3'-0"
SINGLE HUNG,
FIBERGLASS
W2
(2) SINGLE HUNG,
FIBERGLASS
W3
(3) SINGLE HUNG,
FIBERGLASS
9'-0"6'-0"2'-0" 3'-0" 3'-0"3'-0"
W6
(3) SINGLE HUNG
WITH TRANSOM,
FIBERGLASS
9'-0"6'-0" 2'-0" 3'-0" 3'-0"3'-0"2'-0"8'-0"W4 2'-0" 3'-0"6'-0" 6'-0"6'-0" 2'-0" 3'-0" 3'-0"
(1) SINGLE HUNG
WITH TRANSOM,
FIBERGLASS
W5
(2) SINGLE HUNG
WITH TRANSOM,
FIBERGLASS 2'-0"8'-0"2'-0"8'-0"5'-0"6'-0"2'-0" 2'-6" 2'-6"
W2b
(2) SINGLE HUNG,
FIBERGLASS
TYP. BRICK
TRIM PROFILE ARCHITECTCLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031
JANUARY 15, 2021
# DESCRIPTION DATENORTH ENDMULTIFAMILYCARMEL, INDIANABID DOCUMENTS GC/CM
NOTE: ALL WINDOWS THAT ARE LESS
THAN 18 INCHES FROM DOORS ARE TO
RECEIVED TEMPERED GLASS.WINDOW SCHEDULEAND DETAILSA051
BRICK SOLDIER COURSE
SCHEDULE
WINDOW
BRICK ROWLOCK SILL
WINDOW ASSEMBLY
SHIM BY WINDOW INSTALLER
MORTAR NET
BACKER ROD AND
CONTINUOUS SEALANT
WRAP AND FLASH WEATHER
MEMBRANE AROUND
OPENING AS RECOMMENDED
BY WEATHER MEMBRANE
MFR.
CONTINUOUS SELF ADHERING
MEMBRANE OVER LOOSE LINTEL
AND STAINLESS STEEL DRIP EDGE
SCALE:
H1 AT MASONRY
HEAD WINDOW
3" = 1'-0"
LOOSE STEEL LINTEL
PRIMED AND PAINTED
STAINLESS STEEL DRIP EDGE
BRICK WEEP
BRICK SOLDIER COURSE
RETURN GWB AT JAMB
CONT. SEALANT
SPRAY FOAM
CONTINUOUS
SELF-ADHERING
MEMBRANE PRIOR TO
WINDOW AND W.R.B.
INSTALLATION
REF. STRUCTURAL
DWGS. FOR
HEADER INFO.
SCALE:
J1 AT MASONRY
JAMB WINDOW
3" = 1'-0"
1"
CONTINUOUS SELF ADHERING
MEMBRANE FROM INSIDE. SEALANT
BETWEEN MOUNTING FLANGE & W.R.B.
AND BETWEEN MOUNTING FLANGE &
FLEXIBLE FLASHING
SHIM BY WINDOW INSTALLER
WINDOW AS SCHEDULED
SHIM BY WINDOW
INSTALLER
WINDOW AS SCHEDULED
WEATHER MEMBRANE
OVER WINDOW
NAILING FLANGE
CONT. SEALANT
PAINTED 1x WOOD SILL
CONTINUOUS
SELF-ADHERING
MEMBRANE, FROM 1"
MIN. DOWN INSIDE FACE
OF WALL, UP & OVER
SILL PLATE, AND &
OVER EXTERIOR
BUILDING WRAP 6" MIN.
2X WOOD TOP PLATE
1x4 WOOD TRIM
2X WOOD TOP PLATE,
SEE STRUCTURAL
DRAWINGS
CONTINUOUS SEALANT
SPRAY FOAM
SCALE:
S1 AT MASONRY
SILL WINDOW
3" = 1'-0"
BRICK ROWLOCK SILL
BRICK WEEP
MORTAR NET
STAINLESS STEEL DRIP EDGE
BACKER ROD AND
CONTINUOUS SEALANT
CONTINUOUS SELF ADHERING
MEMBRANE FLASHING
2X WOOD STUDS, SEE
STRUCTURAL DRAWINGS
RETURN GWB AT JAMB
CONT. SEALANT
SPRAY FOAM
CONTINUOUS
SELF-ADHERING
MEMBRANE PRIOR TO
WINDOW AND W.R.B.
INSTALLATION
CONTINUOUS SELF ADHERING
MEMBRANE OVER WINDOW
FLANGE, SEALANT BETWEEN
MOUNTING FLANGE & W.R.B.
AND BETWEEN MOUNTING
FLANGE & FLEXIBLE FLASHING
BRICK WEEP
SCALE:
J2 METAL PANEL
JAMB WINDOW AT
3" = 1'-0"
SHIM BY WINDOW
INSTALLER
WINDOW AS SCHEDULED
2X WOOD STUDS, SEE
STRUCTURAL DRAWINGS
RETURN GWB AT JAMB
CONT. SEALANT
SHIM BY WINDOW
INSTALLER
WINDOW AS SCHEDULED
CONT. SEALANT
CONTINUOUS SELF ADHERING
MEMBRANE FROM INSIDE
SEALANT BETWEEN MOUNTING
FLANGE & W.R.B. AND BETWEEN
MOUNTING FLANGE & FLEXIBLE
FLASHING
PAINTED 1x WOOD SILL
1"
CONTINUOUS
SELF-ADHERING
MEMBRANE, FROM 1"
MIN. DOWN INSIDE FACE
OF WALL, UP & OVER
SILL PLATE, AND &
OVER EXTERIOR
BUILDING WRAP 6" MIN.
2X WOOD TOP PLATE
1x4 WOOD TRIM
2X WOOD TOP PLATE,
SEE STRUCTURAL
DRAWINGS
BACKER ROD AND
CONTINUOUS SEALANT
WEATHER MEMBRANE
OVER WINDOW
NAILING FLANGE
CONTINUOS SEALANT
(AND BACKER ROD IF
NECESSARY)
CONTINUOUS SELF ADHERING
MEMBRANE OVER WINDOW
FLANGE SEALANT BETWEEN
MOUNTING FLANGE & W.R.B.
AND BETWEEN MOUNTING
FLANGE & FLEXIBLE FLASHING
SPRAY FOAM
SPRAY FOAM
SCALE:
S2 METAL PANEL
SILL WINDOW AT
3" = 1'-0"
SCALE:
H2 METAL PANEL
HEAD WINDOW AT
3" = 1'-0"
SCALE:
01 WINDOW SCHEDULE
1/4" = 1'-0"
METAL PANEL SYSTEM
J-TRIM / FINISHING CAP
METAL PANEL SYSTEM
J-TRIM / FINISHING CAP
SHIM BY WINDOW
INSTALLER
WINDOW AS SCHEDULED
2X WOOD STUDS, SEE
STRUCTURAL DRAWINGS
RETURN GWB AT JAMB
CONT. SEALANT
WEATHER MEMBRANE
OVER WINDOW
NAILING FLANGE
CONTINUOS SEALANT
(AND BACKER ROD IF
NECESSARY)
CONTINUOUS SELF ADHERING
MEMBRANE OVER WINDOW
FLANGE SEALANT BETWEEN
MOUNTING FLANGE & W.R.B.
AND BETWEEN MOUNTING
FLANGE & FLEXIBLE FLASHING SPRAY FOAM
METAL PANEL SYSTEM
J-TRIM / FINISHING CAP
SCALE:
J3 AT LAP SIDING
JAMB WINDOW DETAILS
3" = 1'-0"
REF. STRUCTURAL DWGS.
FOR HEADER INFO.
SHIM BY WINDOW
INSTALLER
WINDOW AS SCHEDULED
CONT. SEALANT
PAINTED 1x WOOD SILL
CONTINUOUS
SELF-ADHERING
MEMBRANE, FROM 1"
MIN. DOWN INSIDE FACE
OF WALL, UP & OVER
SILL PLATE, AND &
OVER EXTERIOR
BUILDING WRAP 6" MIN.
2X WOOD TOP PLATE
SHIM BY WINDOW
INSTALLER
WINDOW AS SCHEDULED
2X WOOD STUDS, SEE
STRUCTURAL DRAWINGS
RETURN GWB AT JAMB
CONT. SEALANT
RETURN GWB AT JAMB
CONT. SEALANT
WRAP AND FLASH WEATHER
MEMBRANE AROUND
OPENING AS RECOMMENDED
BY WEATHER MEMBRANE
MFR.
SEALANT BETWEEN MOUNTING
FLANGE & W.R.B. AND
BETWEEN MOUNTING FLANGE
& FLEXIBLE FLASHING
CONTINUOUS SELF ADHERING
MEMBRANE, LAP OVER
WINDOW NAILING FLANGE
CONTINUOUS SELF
ADHERING MEMBRANE
FROM INSIDE
SEALANT BETWEEN
MOUNTING FLANGE & W.R.B.
AND BETWEEN MOUNTING
FLANGE & FLEXIBLE
FLASHING
CONTINUOUS SELF
ADHERING MEMBRANE
OVER WINDOW FLANGE
SEALANT BETWEEN
MOUNTING FLANGE & W.R.B.
AND BETWEEN MOUNTING
FLANGE AND FLEXIBLE
FLASHING
1x4 WOOD TRIM
1"
2X WOOD TOP PLATE,
SEE STRUCTURAL
DRAWINGS714"5/4 FIBER CEMENT TRIM
BOARD ON 3/8" FIBER
CEMENT BACKER BOARD
KICK-OUT FLASHING, EXTEND
VERT. LEG UP FACE OF
SHEATHING MIN. 5 INCES
CONTINUOS SEALANT
(AND BACKER ROD IF
NECESSARY)
CONTINUOS SEALANT
5/4 FIBER CEMENT TRIM
BOARD ON 3/8" FIBER
CEMENT BACKER BOARD
312" 5/4 FIBER CEMENT TRIM
BOARD ON 3/8" FIBER
CEMENT BACKER BOARD
CONT. SEALANT
CONTINUOS SEALANT
(AND BACKER ROD IF
NECESSARY)312"WEATHER MEMBRANE
OVER WINDOW
NAILING FLANGE
SPRAY FOAM
SPRAY FOAM
SPRAY FOAM
SCALE:
S3 AT LAP SIDING
SILL WINDOW DETAILS
3" = 1'-0"
SCALE:
H3 AT LAP SIDING
HEAD WINDOW DETAILS
3" = 1'-0"
WINDOW ASSEMBLY
SHIM BY WINDOW INSTALLER
CORROSIVE RESISTANT HEAD
FLASHING, SET IN SEALANT
SCALE:
H4 AT MASONRY
HEAD WINDOW DETAILS
3" = 1'-0"
WINDOW ASSEMBLY
SHIM BY WINDOW INSTALLER
WRAP AND FLASH WEATHER
MEMBRANE AROUND
OPENING AS RECOMMENDED
BY WEATHER MEMBRANE
MFR.
SPRAY FOAM
8" BOND BEAM: SEE
STRUCTURAL DWGS
1X WOOD TRIM
NOMINAL 8" CMU: SEE
STRUCTURAL DWGS FOR
GROUT & REINFORCING
SCALE:
S4 AT MASONRY
SILL WINDOW DETAILS
3" = 1'-0"
SHIM BY WINDOW INSTALLER
WINDOW AS SCHEDULED
BACKER ROD AND
CONTINUOUS SEALANT
NOMINAL 8" CMU: SEE
STRUCTURAL DWGS FOR
GROUT & REINFORCING
NOMINAL 8" CMU GROUT
FULL
PAINTED 1x WOOD SILL
1x WOOD TRIM
CONTINUOUS SEALANT
CONTINUOUS
SELF-ADHERING
MEMBRANE, FROM 1"
MIN. DOWN INSIDE FACE
OF WALL, UP & OVER
SILL PLATE, AND &
OVER EXTERIOR
BUILDING WRAP 6" MIN.
2X WOOD TOP PLATE
CONTINUOUS SEALANT
CONTINUOUS SEALANT
SCALE:
J4 AT MASONRY
JAMB WINDOW DETAILS
3" = 1'-0"
SHIM BY WINDOW
INSTALLER
WINDOW AS SCHEDULED
CONTINUOUS SEALANT
CONTINUOUS SELF ADHERING
MEMBRANE OVER WINDOW
FLANGE, SEALANT BETWEEN
MOUNTING FLANGE & W.R.B.
AND BETWEEN MOUNTING
FLANGE & FLEXIBLE FLASHING
WEATHER MEMBRANE
OVER WINDOW
NAILING FLANGE
NOMINAL 8" CMU: SEE
STRUCTURAL DWGS FOR
GROUT & REINFORCING
CONTINUOUS SEALANT
1x4 WOOD TRIM
CONTINUOUS SEALANT
CONTINUOUS SEALANT
1"
PAINTED WOOD SILL714"KICK-OUT FLASHING, EXTEND
VERT. LEG UP FACE OF
SHEATHING MIN. 5 INCES
5/4 FIBER CEMENT TRIM
BOARD ON 3/8" FIBER
CEMENT BACKER BOARD
CONTINUOUS SELF ADHERING
MEMBRANE, LAP OVER
WINDOW NAILING FLANGE
CORROSIVE RESISTANT HEAD
FLASHING, SET IN SEALANT
CONTINUOUS SELF
ADHERING MEMBRANE
FROM INSIDE
SEALANT BETWEEN
MOUNTING FLANGE & W.R.B.
AND BETWEEN MOUNTING
FLANGE & FLEXIBLE
FLASHING
CONTINUOS SEALANT
(AND BACKER ROD IF
NECESSARY)312"04/15/22