HomeMy WebLinkAboutA113 - BUILDING PLANS - BUILDING AA211 2
A2122
A211
1
68' - 6"
10' - 3" 30' - 0" 26' - 0" 38' - 0" 38' - 0" 38' - 0" 35' - 4 1/2" 2' - 5" 23' - 6"31' - 6" 5' - 6" 31' - 6"31' - 6" 5' - 6" 31' - 6"22' - 9"10' - 3" 43' - 0" 26' - 0" 26' - 0" 26' - 1 1/2" UNIT B2
302
UNIT A1
304
UNIT B1
306
UNIT B1
308
UNIT A2
310
UNIT A1
312
UNIT B3
317
UNIT B2
315UNIT A5
313
UNIT A4
303
UNIT B2
301
UNIT A1
305
UNIT B1
311
UNIT A2
321
UNIT A2
318
UNIT B3b
324
UNIT B2
326
UNIT B2
327
230' - 3"203' - 9 1/2"71' - 0"273' - 10 1/2"160' - 3 1/2"71' - 0"
ELEC.
ROOM
E301
STORAGE
S301
MECH.
ROOM
M301
ELEC.
ROOM
E302
MECH.
ROOM
M302
MECH.
ROOM
M303
UNIT A1
IDD
319
UNIT A1
IDD
323
UNIT A2
IDD
325
UNIT A1
IDD
320
UNIT A1
IDD
322
UNIT B1
307
UNIT B1
309
A212
1
A211 2
A212
1
GENERAL NOTES
1. SEE ID SERIES FOR FINISHES, APPLIANCES,
MILLWORK, PLUMBING FIXTURES & HARDWARE.
2. ALL UNITS IN THIS SET ARE DESIGNED AS
A117.1 ANSI TYPE B UNITS AND ARE TO
COMPLY WITH ACCESSIBILITY CODES LISTED
ON THE COVER SHEET. ADDITIONAL
ACCESSIBILITY IS TO BE PROVIDED AT IDD
UNITS. SEE PROJECT COMMITMENTS SHEETS
FOR REQUIREMENTS AND PLANS FOR UNIT
LOCATIONS.
3. ALL BEDROOM CLOSETS TO HAVE DOUBLE
WOOD SHELF AND ROD CONFIGURATION
UNLESS NOTED OTHERWISE.
4. ALL COAT CLOSETS TO HAVE SINGLE WOOD
SHELF AND ROD CONFIGURATION.
5. ALL LAUNDRY ROOMS TO HAVE SINGLE
WOOD SHELF CONFIGURATION, SHELF TO BE
INSTALLED AT 5'-0" A.F.F. UNLESS NOTED
OTHERWISE.
6. SEE MECHANICAL DRAWINGS FOR IN-WALL
WATER CONNECTIONS.
7. CONTRACTOR TO VERIFY SIZE AND FRAMING
DIMENSIONS OF HVAC UNIT, BATHTUB DOORS
AND WINDOWS.
8. PROVIDE 1x2 PTD WOOD TRIM @ INTERIOR OF
ALL CLOSETS / UTILITY CLOSETS WHERE
STANDARD DOOR CASING WILL NOT FIT.
9. UNDERCUT ALL INTERIOR DOORS FOR
RETURN AIR 1".
10. WRAP ALL EXPOSED PIPES WHERE
REMOVABLE CABINETS ARE PROVIDED.
11. BASE OF MIRROR REFLECTED SURFACE TO
BE INSTALLED 40" AFF MAXIMUM.
12. PROVIDE ELECTRICAL OUTLET IN KITCHEN
ISLAND SIDEWALL 6" BELOW COUNTERTOP
AT CENTERLINE OF WALL. SEE ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
13. ALL CEILING HEIGHTS IN UNITS ARE 9'-0" A.F.F.
14. REFER TO SHEET A311 FOR DEMISING WALL
AND CORRIDOR WALL REQUIREMENTS.
15. ALL WALLS BEHIND PLUMBING FIXTURES TO
BE 2X6 MINIMUM.
16. ALL SLOPED CONCRETE SURFACES ARE TO
RECEIVE BROOM FINISH.
17. ALL OPENINGS THROUGH DRAFTSTOP IN
ATTIC SHALL BE EQUIPPED WITH SELF
CLOSING/LATCHING HARDWARE.
18. ALL PENETRATIONS THROUGH RATED
ASSEMBLIES ARE TO BE PROTECTED AS PER
APPLICABLE UL SYSTEM LISTING.
PLAN NOTES
ALIGN FINISH FACES.
FIRE EXINGUISHER IN SEMI-RECESSED
CABINET, SEE SHEET A400 FOR DETAILS.
CONCRETE STAIRS. PROVIDE HANDRAILS
BOTH SIDES, EXTEND HANDRAILS 1'-0" PAST
TOP AND BOTTOM OF STAIRS.
CONCRETE RAMP, SLOPE UP AT MAXIMUM
1:12 SLOPE. PROVIDE HANDRAILS BOTH
SIDES, EXTEND HANDRAILS 1'-0" PAST TOP
AND BOTTOM OF RAMP.
CORRIDOR PILASTER AND BULKHEAD, SEE
DETAILS IN ID SERIES FOR MORE
INFORMATION.
2O"x30" MINIMUM ATTIC ACCESS PANEL.
48"X48" ROOF HATCH WITH BUILT-UP CURB.
2-HOUR FIRE WALL AT THIS LOCATION, SEE
SHEET A341 FOR MORE INFORMATION.
2-HOUR RATED MECHANICAL SHAFT, SEE
SHEET A341 FOR MORE INFORMATION.
TENANT MAILBOXES AND PARCEL BOXES AT
THE LOCATION, SEE INTERIOR ELEVATIONS
FOR CONFIGURATION.
INDOOR PACKAGE MANAGEMENT SYSTEM AT
THIS LOCATION, SEE INTERIOR ELEVATIONS
FOR CONFIGURATION.
1
2
3
4
5
6
7
8
9
10
11 ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031
JANUARY 15, 2021
BID DOCUMENTS
A113BUILDING PLANS -BUILDING ANORTH ENDAPARTMENTSCARMEL, IN# DESCRIPTION DATE
1 BID DOCUMENTS 01-15-21
SCALE: 3/32" = 1'-0"1 BUILDING A THIRD FLOOR PLAN - OVERALL
1
04/15/22