HomeMy WebLinkAboutA114a - BUILDING PLANS - BUILDING AROOF PLAN LEGEND
1 TPO MEMBRANE ROOF - SEE WALL SECTIONS
AND ASSEMBLY SHEETS
ATTIC DRAFTSTOPPING, SEE DETAILS ON
SHEET A341. DRAFTSTOPPING TO EXTEND
HORIZONTALLY TO INCLUDE EAVE/SOFFIT.
INDIVIDUAL AREAS OF SEPARATION BETWEEN
DRAFTSTOPPING NOT TO EXCEED 3,000SF.
PROVIDE ACCESS DOOR, 24"X30" MIN., FOR
EACH AREA OF SEPARATION AS INDICATED.
CROSS HATCH REPRESENTS TAPERED
INSULATION AT 1/4" PER FOOT TO ACHIEVE
POSITIVE DRAINAGE.
6" ALUMINUM GUTTER WITH ALUMINUM
DOWNSPOUTS
48" X 48" ROOF HATCH WITH BUILT-UP CURB -
SEE DETAIL 09/A341 AND SPECIFICATIONS
FOR MORE INFORMATION.
DASHED LINE REPRESENTS CENTER OF 2-
HOUR FIRE WALL BELOW. PROVIDE MINIMUM
4'-0" OF FIRE RETARDENT ROOF SHEATHING
ON BOTH SIDES.
TPO SLIP-RESISTANT WALKWAY PAD,
30" WIDE
20" X 30" MINIMUM ATTIC ACCESS PANEL
METAL COPING ON PARAPET
ROOF DRAIN WITH SECONDARY OVERFLOW.
SEE PLUMBING DRAWINGS FOR MORE
INFORMATION.
12" x 12" PREFINISHED LOUVER IN
MECHANICAL WELL WALL, COLOR TO BE
SELECTED BY ARCHITECT. INSTALL BOTTOM
AT 15" ABOVE FLAT ROOF STRUCTURE.
#
2
3
4
5
6
7
9
8
10
11
GENERAL NOTES
1. SEE ID SERIES FOR FINISHES, APPLIANCES,
MILLWORK, PLUMBING FIXTURES & HARDWARE.
2. ALL UNITS IN THIS SET ARE DESIGNED AS
A117.1 ANSI TYPE B UNITS AND ARE TO
COMPLY WITH ACCESSIBILITY CODES LISTED
ON THE COVER SHEET. ADDITIONAL
ACCESSIBILITY IS TO BE PROVIDED AT IDD
UNITS. SEE PROJECT COMMITMENTS SHEETS
FOR REQUIREMENTS AND PLANS FOR UNIT
LOCATIONS.
3. ALL BEDROOM CLOSETS TO HAVE DOUBLE
WOOD SHELF AND ROD CONFIGURATION
UNLESS NOTED OTHERWISE.
4. ALL COAT CLOSETS TO HAVE SINGLE WOOD
SHELF AND ROD CONFIGURATION.
5. ALL LAUNDRY ROOMS TO HAVE SINGLE
WOOD SHELF CONFIGURATION, SHELF TO BE
INSTALLED AT 5'-0" A.F.F. UNLESS NOTED
OTHERWISE.
6. SEE MECHANICAL DRAWINGS FOR IN-WALL
WATER CONNECTIONS.
7. CONTRACTOR TO VERIFY SIZE AND FRAMING
DIMENSIONS OF HVAC UNIT, BATHTUB DOORS
AND WINDOWS.
8. PROVIDE 1x2 PTD WOOD TRIM @ INTERIOR OF
ALL CLOSETS / UTILITY CLOSETS WHERE
STANDARD DOOR CASING WILL NOT FIT.
9. UNDERCUT ALL INTERIOR DOORS FOR
RETURN AIR 1".
10. WRAP ALL EXPOSED PIPES WHERE
REMOVABLE CABINETS ARE PROVIDED.
11. BASE OF MIRROR REFLECTED SURFACE TO
BE INSTALLED 40" AFF MAXIMUM.
12. PROVIDE ELECTRICAL OUTLET IN KITCHEN
ISLAND SIDEWALL 6" BELOW COUNTERTOP
AT CENTERLINE OF WALL. SEE ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
13. ALL CEILING HEIGHTS IN UNITS ARE 9'-0" A.F.F.
14. REFER TO SHEET A311 FOR DEMISING WALL
AND CORRIDOR WALL REQUIREMENTS.
15. ALL WALLS BEHIND PLUMBING FIXTURES TO
BE 2X6 MINIMUM.
16. ALL SLOPED CONCRETE SURFACES ARE TO
RECEIVE BROOM FINISH.
17. ALL OPENINGS THROUGH DRAFTSTOP IN
ATTIC SHALL BE EQUIPPED WITH SELF
CLOSING/LATCHING HARDWARE.
18. ALL PENETRATIONS THROUGH RATED
ASSEMBLIES ARE TO BE PROTECTED AS PER
APPLICABLE UL SYSTEM LISTING.
A211 2
A211
1
8" / 12" 8" / 12" 8" / 12"8" / 12"
8" / 12" 8" / 12"8" / 12"
8" / 12" 8" / 12"8" / 12"8" / 12" 8" / 12"
8" / 12" 8" / 12" 8" / 12"8" / 12"
8" / 12" 8" / 12"8" / 12" 8" / 12" 8" / 12"8" / 12" 8" / 12" 8" / 12"8" / 12" 3" / 12"2" / 12"2" / 12"2
22 2 2 2
2
10
3
3
3
3
3
3
4
4
4
4
4 4
5
2
2
2
2
10
10 10
2
2
2
2
3
6
2
9
1
9
1
2
9
4 4
4 4
1
8
8
8
8
8
7
7
7
1 ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031
JANUARY 15, 2021
BID DOCUMENTS
A114aBUILDING PLANS -BUILDING ANORTH ENDAPARTMENTSCARMEL, INSCALE: 1/8" = 1'-0"1 BUILDING A ROOF PLAN -AREA A
# DESCRIPTION DATE
1 BID DOCUMENTS 01-15-21
04/15/22