HomeMy WebLinkAboutA161 - ELEVATOR PLANS AND DETAILSBOTTOM OF PIT
EL. -3'-4" A.F.F.
LOWER LEVEL
EL. -10'-8"
SECOND FLOOR
EL: +10'-8"
THIRD FLOOR
EL. +21'-4"
PLATE BEARING
EL. +41'-1"
T/O CMU
EL. +46'-4"
FIRST FLOOR
EL: +0'-0"
FOURTH FLOOR
EL. +32'-0"
BOTTOM OF PIT
EL. -3'-4" A.F.F.
SECOND FLOOR
EL: +10'-8"
THIRD FLOOR
EL. +21'-4"
PLATE BEARING
EL. +41'-1"
T/O CMU
EL. +46'-4"
FIRST FLOOR
EL: +0'-0"
FOURTH FLOOR
EL. +32'-0"
BOTTOM OF PIT
EL. -3'-4" A.F.F.
FIRST FLOOR
EL: +0'-0"
SECOND FLOOR
EL. +14'-0"
PLATE BEARING
EL. +33'-9"
T/O CMU
EL. +39'-0"
LOWER LEVEL
EL: -10'-8"
THIRD FLOOR
EL. +24'-8"
A161ELEVATOR PLANSAND DETAILSSCALE:
01 LOWER LEVEL PLAN
ELEVATOR
1/4" = 1'-0" SCALE:
04 ELEVATOR SECTION
BUILDING B
1/4" = 1'-0"7'-0" 7'-0" 7'-0" 7
A161
HOISTWAY BEAM SIZE AND PLACEMENT
AS REQUIRED BY ELEVATOR PROVIDED
AND INSTALLED BY G.C.12'-8"13'-578"1'-7"
ALIGN TOP RUNG WITH
FINISH FLOOR
STL. LADDER: 1 2"x4" FLAT
BARS 16" APART ATTACHED
TO WALL W/(3) 2"x7"x3 8" STL.
ANGLES 1 2" RUNGS @ 12" O.C.
SUMP PIT, REFERENCE
STRUCTURAL DWGS. FOR
ADDITIONAL INFO.
SEE STRUCTURAL FOR
WATERPROOFING EXTENTS
PASSENGER ELEVATOR BASIS OF DESIGN
SCHINDLER 3300 TRACTION ELEVATOR
3500 LBS, 100 FPM
FRONT OPENINGS - CENTERED
SCALE:
07 SECTION DETAIL
1/4" = 1'-0"
ROOFING MEMBRANE FLASHING
ON FINISHED METAL
COPING/GRAVEL STOP
EXTEND ROOFING MEMBRANE
UNDER MTL. COPING AND DOWN
FACE OF SHEATHING 4" MIN.
PRE-FINISHED METAL
COPING/GRAVEL STOP
WOOD BLOCKING AS REQUIRED
ROOFING MEMBRANE TO
EXTEND UP AND OVER
ELEVATOR WALLS
EXTEND WEATHER
BARRIER DOWN TO
MEET ROOF SHEATHING
PROVIDE CONTINUOUS SEALANT
AT ENTIRE PERIMETER
WG3A
WC1R3F3 F2a F1 R4R3R4R3F3 F2a F1 PROVIDE INSULATION IN
ATTIC SPACE UP SIDE OF
ELEVATOR WALL
5'-0"SCALE:
02 SECOND FLOOR PLAN
ELEVATOR
1/4" = 1'-0"
SCALE:
03 THIRD FLOOR PLAN
ELEVATOR
1/4" = 1'-0"
WC1
4
A191
WC1 WC1
75 8"
8'-6"
75 8" WC17'-10" 758" 8'-6"75 8" 75 8"1"TYP.758" ARCHITECTCLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031
JANUARY 15, 2021
# DESCRIPTION DATENORTH ENDMULTIFAMILYCARMEL, INDIANABID DOCUMENTS GC/CM 7'-0" 7'-0"SCALE:
05 ELEVATOR SECTION
BUILDING C
1/4" = 1'-0"7'-0" 7'-0" 7
A161
HOISTWAY BEAM SIZE AND PLACEMENT
AS REQUIRED BY ELEVATOR PROVIDED
AND INSTALLED BY G.C.12'-8"13'-578"1'-7"
ALIGN TOP RUNG WITH
FINISH FLOOR
STL. LADDER: 1 2"x4" FLAT
BARS 16" APART ATTACHED
TO WALL W/(3) 2"x7"x3 8" STL.
ANGLES 1 2" RUNGS @ 12" O.C.
SUMP PIT, REFERENCE
STRUCTURAL DWGS. FOR
ADDITIONAL INFO.
SEE STRUCTURAL FOR
WATERPROOFING EXTENTS
PASSENGER ELEVATOR BASIS OF DESIGN
SCHINDLER 3300 TRACTION ELEVATOR
3500 LBS, 100 FPM
FRONT OPENINGS - CENTERED
WG3A
WC1
F1F1PROVIDE INSULATION IN
ATTIC SPACE UP SIDE OF
ELEVATOR WALL
5'-0"7'-0" 7'-0"SCALE:
06 ELEVATOR SECTION
BUILDING A
1/4" = 1'-0" 7'-0"7'-0" 7
A161
HOISTWAY BEAM SIZE AND PLACEMENT
AS REQUIRED BY ELEVATOR PROVIDED
AND INSTALLED BY G.C.12'-8"13'-578"1'-7"
ALIGN TOP RUNG WITH
FINISH FLOOR
STL. LADDER: 12"x4" FLAT
BARS 16" APART ATTACHED
TO WALL W/(3) 2"x7"x3 8" STL.
ANGLES 1 2" RUNGS @ 12" O.C.
SUMP PIT, REFERENCE
STRUCTURAL DWGS. FOR
ADDITIONAL INFO.
SEE STRUCTURAL FOR
WATERPROOFING EXTENTS
PASSENGER ELEVATOR BASIS OF DESIGN
SCHINDLER 3300 TRACTION ELEVATOR
3500 LBS, 100 FPM
FRONT OPENINGS - CENTERED
WG3A
WC1 F2aF1 F2a F1 PROVIDE INSULATION IN
ATTIC SPACE UP SIDE OF
ELEVATOR WALL
5'-0"7'-0"F2F27'-0"R3R4R3R3R4R3F3F3F3F3F3F3F3F3F3F3F3F3WC1
4
A191
WC1WC1
75 8"
8'-6"
75 8" WC17'-10"758"8'-6"75 8" 75 8"1"TYP.758" WC1
4
A191
WC1 WC1
10"
8'-6"
10" WC17'-10" 10" 8'-6"10" 10"1"TYP.10" PROVIDE HOISTWAY VENTING, SEE
MECHANICAL DRAWINGS FOR MORE
INFORMATION
PROVIDE HOISTWAY VENTING, SEE
MECHANICAL DRAWINGS FOR MORE
INFORMATION
PROVIDE HOISTWAY VENTING, SEE
MECHANICAL DRAWINGS FOR MORE
INFORMATION
04/15/22