HomeMy WebLinkAboutA343 - INTERIOR WALL SECTIONSINTERIOR WALLSECTIONSA343 ARCHITECTCLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031 JANUARY 15, 2021 # DESCRIPTION DATENORTH ENDMULTIFAMILYCARMEL, INDIANABID DOCUMENTS GC/CM SCALE: 02 WALL SECTION RADON VENT 3/8" = 1'-0"F1 F2a R3F1 R3FIRST FLOOR EL: ± 0'-0" SECOND FLOOR EL: 10'-8" ROOF PLATE EL: 30'-5 1/8" 3" PVC DWV PIPE LOCATED IN 2X6 STUD WALL, SEE PLANS FOR LOCATION JUNCTION BOX FOR FUTURE ACTIVE VENT FAN BY ELECTRICAL CONTRACTOR - SEE ELECTRICAL PLANS12"MIN.F2a SCALE: 03 WALL SECTION RADON VENT 3/8" = 1'-0" F1 F3 R3F1 R3FIRST FLOOR EL: ± 0'-0" SECOND FLOOR EL: 10'-8" THIRD FLOOR EL: 21'-4" ROOF PLATE EL: 30'-5 1/8" 3" PVC DWV PIPE LOCATED IN 2X6 STUD WALL, SEE PLANS FOR LOCATION JUNCTION BOX FOR FUTURE ACTIVE VENT FAN BY ELECTRICAL CONTRACTOR - SEE ELECTRICAL PLANS12"MIN.F3 FOURTH FLOOR EL: 32'-0" LOWER LEVEL EL: -10'-8" THIRD FLOOR EL: 21'-4"F3F3FOURTH FLOOR EL: 32'-0" THIRD FLOOR EL: 21'-4" SCALE: 01 WALL SECTION RADON VENT 3/8" = 1'-0" F1 F2a F2 R3F1 R3FIRST FLOOR EL: ± 0'-0" SECOND FLOOR EL: 14'-0" ROOF PLATE EL: 33'-9" 3" PVC DWV PIPE LOCATED IN 2X6 STUD WALL, SEE PLANS FOR LOCATION 1. MAINTAIN 10' FROM BUILDING OPENINGS. 2. PIPES SHALL BE INSTALLED SO RAINWATER OR CONDENSATION DRAINS DOWNWARD INTO THE GROUND BENEATH THE SLAB AND VAPOR BARRIER. 3. RADON VENT PIPES TO BE INSTALLED IN ACCORDANCE W/ASTM E1465 - 08A FOR SOIL GAS COLLECTOR TYPE 5 SYSTEM. 4. COORDINATE FINAL LOCATION OR RADON VENTING WITH ARCHITECTURAL PLAN JUNCTION BOX FOR FUTURE ACTIVE VENT FAN BY ELECTRICAL CONTRACTOR - SEE ELECTRICAL PLANS12"MIN.F2a F2 F3F3LOWER LEVEL EL: -10'-8" THIRD FLOOR EL: 24'-8"F3 F3 F3 F3 F3 F3 F3F31 BID DOCUMENTS 01-15-21 1 04/15/22