HomeMy WebLinkAboutE401 - ELECTRICAL ENLARGED PLANSSS S CO S S SCO SS S CO S S SCO EF 3 WP 8 PNL-A2 IDD 12 3 CU-1 9,11 4 5 6 7 8 9 9 10 1112 13 13 14 15 16 17 18 FCU-1 14,16 WH-1 13,15 A3 1 A3 1 A3 1 A3 1 A2 1 A3 1 A3 1 A3 1 A3 1 A3 1 A3 1 A4 1 A4 1 A4 1 A3 1 A3 3 A1 3 7 7 7 7 7 8 8 8 8 8 2 2 2 2 25 20 10,12 3 17,19 18 4 4 8 6 2 8 A5 1 21 C B A D E F 19 PNL-A1 IDD 12 3 4 5 6 7 8 9 9 10 1112 13 13 14 15 16 17 18 A3 2 A3 2 A3 2 A4 2 A4 2 A4 2 A3 2 A3 2 A3 2 A3 2 A3 2 A3 2 A3 2 A3 2 A5 2 A2 2 A3 3 CU-1 10,12 FCU-1 17,19 WH-1 14,16 5 5 5 5 5 8 8 8 8 8 3 8 18,20 7 6 6 6 21 6 6 4 9 EF 3 4 WP 8 13,15 11 1 6 8 A1 3 F C D B E A 19 PNL-A2 1 2 3 CU-1 20,22 4 5 6 7 8 9 9 10 11 12 13 13 14 15 16 17 18 A3 1 A3 1 A3 1 A3 1 A2 A3 1 A3 1 A3 1 A3 1 A3 1 A3 1 A4 1 A4 1 A4 1A3 1 A3 2 A1 2 A5 1 11 11 11 11 11 10 10 10 10 10 3 3 3 33 8 7 FCU-1 17,19WH-1 16,18 13,15 14 2 4,65 9 9 EF 2 WP 10 10 12 3 10 C B D E F A 19 A1 12 PNL-A1 EF 12 WP 14 12 3 CU-1 19,21 FCU-1 15,17 4 5 6 7 8 9 9 10 11 12 13 13 14 15 16 1718 WH-1 16,18 A3 20 A3 20 A3 20 A4 20 A4 20 A4 20 A3 20 A3 20 A3 20 A3 12 A3 20 A3 20 A3 20 A3 20 A5 20 A2 20 13 13 13 13 13 1414 14 14 14 12 11 7,9 6 11 11 11 1 11 11108 10 2,4 3 5 11 14 A3 12 A B C D E F 19 ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031 JANUARY 15, 2021 BID SET E401ELECTRICALENLARGED PLANSNORTH ENDAPARTMENTSCARMEL, IN1/4" = 1'-0" UNIT A2 IDD ELECTRICAL PLAN4 SHEET KEYNOTES 1 1)NEMA-5 20 RECEPTACLE AND 20 A CIRCUIT (2#12,#12G) FOR MICROWAVE/HOOD.(INSTALL IN LOWER RIGHT CORNER OF UPPER CABINET) 2 2)NEMA 14-50R RECEPTACLE AND 50A (3#6,10G CU) CIRCUIT FOR RANGE. COORDINATE EXACT REQUIREMENTS WITH OWNER FURNISHED EQUIPMENT. 3 208 V CIRCUIT (2#10G), CONNECTION AND DISCONNECT SWITCH(30A:2P WP) FOR ACCU. SHOWN HERE FOR REFERENCE,ACCU IS LOCATED ON ROOF AND CIRCUIT TO UNIT PANEL 4 PUSH SWITCH FOR GARBAGE DISPOSER 5 JUNCTION BOX FOR ENERGY-STAR CEILING FAN WITH LIGHT COMBINATION. PROVIDE CEILING FAN SUPPORT AND BLOCKING HER MANUFACTURERS INSTALLATION INSTRUCTIONS. 6 FLUSH MOUNTED LOAD CENTER. PRESERVE FIRE RATING OF WALL. 7 NEMA 5-20R RECEPTACLE AND 20A (2#12,#12G) FOR WASHER. 8 NEMA 14-30R RECEPTACLE AND 30A CIRCUIT (3#10,#10G) FOR DRYER 9 SMOKE DETECTORS WITH SOUNDER BASE CONNECTED TO UNSWITCHED HOT CONDUCTOR IN CIRCUIT. BUILT IN STORES IN ADAPTABLE UNITS. AUDIO/VISUAL HEARING IMPAIRED DEVICES IN ALL HANDICAP UNITS THAT ARE FOR VISUALLY/HEARING IMPAIRED. TYPICAL. 10 SPLIT WIRED DUPLEX RECEPTACLE FOR DISHWASHER. 11 30A,2 POLE,NEMA 1 DISCONNECT SWITCH FOR WATER HEATER,CIRCUIT WITH 2#10,#10G. 12 30A,2 POLE,NEMA 1 DISCONNECT SWITCH FOR FOR FCU,CIRCUIT WITH 2#10,#10G. 13 SPLIT WIRED DUPLEX RECEPTACLE. CONTROL UPPER HALF SWITCH NEAR DOOR.LOWER HALF UNSWITCHED 14 INSTALL DUPLEX RECEPTACLE INSIDE HOME NETWORKING ENCLOSURE CABINET 15 ONE VOICE/DATA JACK AND ONE(1) VIDEO JACK IN THE VOICE/DATA/VIDEO OUTLETS.RUN ONE (1) RG -6 COAX CABLE AND ONE (1) CATEGORY 6 VOICE/DATA CABLE FROM VOICE/DATA/VIDEO OUTLET TO THE HOME NETWORKING CABINET ENCLOSURE 16 RUN VOICE/DATA JACK AND ONE (1) VIDEO JACK IN THE VOICE/DATA/VIDEO CABLES AS REQUIRED FROM THE HOME NETWORKING ENCLOSURE CABINET TO THE VOICE/DATA/VIDEO EQUIPMENTG CABINET IN THE NEARESR ELECTRICAL ROOM 17 EXHAUST FAN WIRED ON/OFF SWITCH 18 FOUR (4) 40 USB CHARGERS IN SINGLE GANGBOX, MOUNTED +44" AFF RPOUTE CAT 5E CABLE BACK TO HOME NETWORKING ENCLOSURE. 19 CARBON MONOXIDE DETECTOR CONNECTED TO UNSWITCHED HOT CONDUCTOR IN CIRCUIT. BUILT IN STORES IN ADAPTABLE UNITS. 1/4" = 1'-0" UNIT A1 IDD ELECTRICAL PLAN2 1/4" = 1'-0" UNIT A2 ELECTRICAL PLAN3 GENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO SHEET E-601 FOR LIGHT FIXTURE SCHEDULE. C REFER TO E-600 SERIES SHEETS FOR LOAD CENTER CIRCUIT SCHEDULES FOR EACH DWELLNG UNIT TYPE. D ELECTRICAL LAYOUTS SHOWN SHALL BE TYPICAL FOR EACH RESIDENTIAL UNIT TYPE IDENTIFIED UNLESS OTHERWISE NOTED. E LIGHT FIXTURE LOCATIONS SHOWN SHALL BE SUPERCEDED BY THE ARCHITECTURAL REFLECTED CEILING PLANS. F INSTALL MULTIPLE SWITCHES SHOWN IN A SINGLE LOCATION BEHIND A SINGLE MULTI-GANG SWITCH FACEPLATE. INSTALL A MAXIMUM OF FOUR (4) SWITCHES BEHIND A SINGLE SWITCH FACEPLATE. G CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF MECHANICAL EQUIPMENT WITH THE MECHANICAL CONTRACTOR. EXACT ELECTRICAL REQUIREMENTS SHALL BE FIELD VERIFIED AGAINST THE EQUIPMENT NAME PLATE DATA. THE CONTRACTOR SHALL MAKE APPROPRIATE ADJUSTMENTS OF FEEDER CIRCUIT CONDUCTORS AND OVERCURRENT PROTECTION PER MANUFACTURER. H ALL RECEPTACLES LOCATED IN KITCHENS AND BATHROOMS SHALL BE GFCI TYPE. I LOAD CENTERS FOR EACH DWELLING UNIT SHALL BE RECESSED IN WALL AS INDICATED. LOAD CENTER SHALL NOT BE INSTALLED IN DEMISING WALL. J PROVIDE DUPLEX RECEPTACLE ON DEDICATED CIRCUIT IN HOMENETWORKING CABINET. K ALL SMOKE ALARM DEVICES WITHIN EACH DWELLING UNIT SHALL BE INTERCONNECTED AND ONLY ALARM WITHIN THE DWELLING UNIT THEY RESIDE. L THE BUILDING FIRE ALARM CONTROL PANEL SHALL MONITOR THE STATUS OF EACH SMOKE ALARM UNIT WITHIN EACH DWELLING UNIT. M DWELLING UNIT SMOKE ALARM DEVICES SHALL BE POWERED BY THE BUILDING FIRE ALARM SYSTEM. N PROVIDE LOW FREQUENCY AUDIBLE DEVICE WITHIN EACH SLEEPING AREA AND LIVING AREA AS INDICATED ON EACH DWELLING UNIT TYPE. AUDIBLE DEVICES SHALL ALARM UPON ACTIVATION OF BUILDING FIRE ALARM SYSTEM AND DWELLING UNIT SMOKE ALARM DEVICES. O DWELLING UNITS NOTED AS ADA ACCESSIBLE SHALL BE EQUIPPED WITH FIRE ALARM VISUAL DEVICES WITHIN BEDROOMS, BATHROOMS AND COMMON LIVING AREAS AS NOTED ON PLANS. P DWELLING UNITS NOTED AS ADA ACCESSIBLE ELECTRICAL PANELS SHALL BE MOUNTED SO AS THE HIGHEST BREAKER IS NO HIGHER THAN 48" ABOVE FINISHED FLOOR # DESCRIPTION DATE 1 BID DOCUMENT 01/15/2021 SWITCHING SCHEDULE TYPE 1ST SWITCH TYPE 1ST SWITCH FUNCTION 2ND SWITCH TYPE 2ND SWITCH FUNCTION 3RD SWITCH TYPE 3RD SWITCH FUNCTION 4TH SWITCH TYPE 4TH SWITCH FUNCTION A SNAP ENTRY A3 FIXTURE SNAP KITCHEN A3 FIXTURES SNAP KITCHEN A4 FIXTURES B SNAP DINING A3 FIXTURES SNAP HALLWAY A3 FIXTURE C SNAP LIVING A3 FIXTURES SNAP BALCONY A5 FIXTURE D DUAL-SLIDE BEDROOM A2 CEILING FIXTURE SNAP BEDROOM SWITCHED RECEPTACLE E SNAP RESTROOM FIXTURES SNAP RESTROOM EXHAUST FAN F SNAP CLOSET A3 FIXTURE G SNAP LIVING A3 FIXTURES SNAP DINING A3 FIXTURES SNAP BALCONY A5 FIXTURE H SNAP HALLWAY A3 FIXTURE I THREE-WAY SNAP HALLWAY A3 FIXTURE J THREE-WAY SNAP ENTRY A3 FIXTURE K SNAP DINING A3 FIXTURES SNAP BALCONY A5 FIXTURE L SNAP LIVING A3 FIXTURES SNAP HALLWAY A3 FIXTURE M SNAP ENTRY A3 FIXTURE SNAP HALLWAY A3 FIXTURE N SNAP KITCHEN A3 FIXTURES SNAP KITCHEN A4 FIXTURES O SNAP LIVING A3 FIXTURES 1/4" = 1'-0" UNIT A1 ELECTRICAL PLAN 1 1 07/08/21