HomeMy WebLinkAboutE403 - ELECTRICAL ENLARGED PLANSS
S
SS
S
CO
CO
S
S
S
SSCO
CO
S
S
S
SCO
CO S
S
S SCO
CO
PNL-B1
A1
2
A2
1
A2
1
A1
3
A5
1
WP
11
A4
1
A4
1
A4
1
12
3
4
5
5
6
7
8
9
9 9
9
10
1112
13
13
13
14
15 16
17
EF
2
18
CU-2
22,24
FCU-2
18,20
WH-1
19,21
17
EF
3
12
12
12
12
12
2
14
13
13 13
13
13 1316
16
15
11
11
11
11
11
5
4,6
10
10
10
10 10
10
3
7,9 8
A3
1
A3
1
A3
1
A3
1
A3
1
A3
1
A3
1
A3
1
A3
1
A3
1
A3
1
A3
3
A3
3
A3
3
A3
2
A3
2
A3
1
A1
3
F
F
F
E
E
C
D
17
D
H
A
B
13
19
19
PNL-B2
A2
3
A4
3
A4
3
A4
3
A1
19
1
2
3
4
5
5
6
7
8
9
9
9
9
1011 12
13
13
13
14
15 16
FCU-2
18,20
WH-1
13,15
EF
19
17
17 EF
6
CU-2
9,11
18
WP
2
A5
3
A3
19
A3
19
A3
6
A1
6
A3
3
A3
3
A3
3
A2
3
A3
3
A3
3
A3
3
A3
3
A3
3
A3
3
A3
3
A3
3
A3
3
A3
3
17
17
17
17
17
7 7
7
7 7
2 2 2
2
2
2
19
10,12
23
6
14,16
2122
22 22 8
4
4
22
22
5
1
F
D
E
F
E
D
A
J
K
L
7
19
19
A2
2
A2
2
A1
1
A1
1
A1
3
A4
2
A4
2
A4
2
A5
2
WP
5
PNL-B3b
1
2
3
4
5 5
6
7
8
9
9
9
10
11 12
13
13
13
15 16
14
18
17
17
EF
1
WH-1
12,14
FCU-2
13,15
CU-2
21,23
EF
3
20 20
20
20
20
1
19
19
19
19
19
19
16,18
17
3
7,9
8
4 4 4
6
4 4 11
11
10
5
5
5 5
5
5
4
22
A3
2
A3
2
A3
2
A3
2
A3
2
A3
2
A3
2
A3
2
A3
2
A3
2
A3
2
A3
2
A3
1
A3
1
A3
1
A3
3
A3
2
5
F
F
A3
2ED D F
E
A
B
C
I 3
4
19
19
PNL-B3
23
23
23
23
2323
9
9
9
9
99
13,15
22
8
18,20
21
CU-2
10,12
6
A3
2
EF
2
A3
2
A3
2
A1
2
A1
2
2
4
A1
4
A3
4
EF
4
4
5
5 55
5
5
7
7
11
11 11
11
11 11 11
11
F
E
E
D D
A
F
I
B
FCU-2
17,19
WH-1
14,16
C
1
2 18
4 10
11
12
17
17
3
13
55
14
15 16
1
9
9
9
A3
3
17
7
8
13 13
6
A3
3 A3
3
A3
3
A3
3
A3
3
A3
3
A3
3
A2
3
A2
3
A3
3
F
A3
3
A3
3
A3
3
A3
3
A4
3
A4
3
A4
3
A3
3
19
19 ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031
JANUARY 15, 2021
BID SET
E403ELECTRICALENLARGED PLANSNORTH ENDAPARTMENTSCARMEL, IN1/4" = 1'-0"
UNIT B1 ELECTRICAL PLAN1 1/4" = 1'-0"
UNIT B2 ELECTRICAL PLAN3
SHEET KEYNOTES
1 1)NEMA-5 20 RECEPTACLE AND 20 A CIRCUIT (2#12,#12G) FOR
MICROWAVE/HOOD.(INSTALL IN LOWER RIGHT CORNER OF UPPER CABINET)
2 2)NEMA 14-50R RECEPTACLE AND 50A (3#6,10G CU) CIRCUIT FOR RANGE.
COORDINATE EXACT REQUIREMENTS WITH OWNER FURNISHED EQUIPMENT.
3 208 V CIRCUIT (2#10G), CONNECTION AND DISCONNECT SWITCH(30A:2P WP)
FOR ACCU. SHOWN HERE FOR REFERENCE,ACCU IS LOCATED ON ROOF AND
CIRCUIT TO UNIT PANEL
4 PUSH SWITCH FOR GARBAGE DISPOSER
5 JUNCTION BOX FOR ENERGY-STAR CEILING FAN WITH LIGHT COMBINATION.
PROVIDE CEILING FAN SUPPORT AND BLOCKING HER MANUFACTURERS
INSTALLATION INSTRUCTIONS.
6 FLUSH MOUNTED LOAD CENTER. PRESERVE FIRE RATING OF WALL.
7 NEMA 5-20R RECEPTACLE AND 20A (2#12,#12G) FOR WASHER.
8 NEMA 14-30R RECEPTACLE AND 30A CIRCUIT (3#10,#10G) FOR DRYER
9 SMOKE DETECTORS WITH SOUNDER BASE CONNECTED TO UNSWITCHED HOT
CONDUCTOR IN CIRCUIT. BUILT IN STORES IN ADAPTABLE UNITS.
AUDIO/VISUAL HEARING IMPAIRED DEVICES IN ALL HANDICAP UNITS THAT ARE
FOR VISUALLY/HEARING IMPAIRED. TYPICAL.
10 SPLIT WIRED DUPLEX RECEPTACLE FOR DISHWASHER.
11 30A,2 POLE,NEMA 1 DISCONNECT SWITCH FOR WATER HEATER,CIRCUIT WITH
2#10,#10G.
12 30A,2 POLE,NEMA 1 DISCONNECT SWITCH FOR FOR FCU,CIRCUIT WITH
2#10,#10G.
13 SPLIT WIRED DUPLEX RECEPTACLE. CONTROL UPPER HALF SWITCH NEAR
DOOR.LOWER HALF UNSWITCHED
14 INSTALL DUPLEX RECEPTACLE INSIDE HOME NETWORKING ENCLOSURE
CABINET
15 ONE VOICE/DATA JACK AND ONE(1) VIDEO JACK IN THE VOICE/DATA/VIDEO
OUTLETS.RUN ONE (1) RG -6 COAX CABLE AND ONE (1) CATEGORY 6
VOICE/DATA CABLE FROM VOICE/DATA/VIDEO OUTLET TO THE HOME
NETWORKING CABINET ENCLOSURE
16 RUN VOICE/DATA JACK AND ONE (1) VIDEO JACK IN THE VOICE/DATA/VIDEO
CABLES AS REQUIRED FROM THE HOME NETWORKING ENCLOSURE CABINET
TO THE VOICE/DATA/VIDEO EQUIPMENTG CABINET IN THE NEARESR
ELECTRICAL ROOM
17 EXHAUST FAN WIRED ON/OFF SWITCH
18 FOUR (4) 40 USB CHARGERS IN SINGLE GANGBOX, MOUNTED +44" AFF
RPOUTE CAT 5E CABLE BACK TO HOME NETWORKING ENCLOSURE.
19 CARBON MONOXIDE DETECTOR CONNECTED TO UNSWITCHED HOT
CONDUCTOR IN CIRCUIT. BUILT IN STORES IN ADAPTABLE UNITS.
GENERAL NOTES
A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND
ABBREVIATIONS.
B REFER TO SHEET E-601 FOR LIGHT FIXTURE SCHEDULE.
C REFER TO E-600 SERIES SHEETS FOR LOAD CENTER CIRCUIT SCHEDULES
FOR EACH DWELLNG UNIT TYPE.
D ELECTRICAL LAYOUTS SHOWN SHALL BE TYPICAL FOR EACH RESIDENTIAL
UNIT TYPE IDENTIFIED UNLESS OTHERWISE NOTED.
E LIGHT FIXTURE LOCATIONS SHOWN SHALL BE SUPERCEDED BY THE
ARCHITECTURAL REFLECTED CEILING PLANS.
F INSTALL MULTIPLE SWITCHES SHOWN IN A SINGLE LOCATION BEHIND A
SINGLE MULTI-GANG SWITCH FACEPLATE. INSTALL A MAXIMUM OF FOUR (4)
SWITCHES BEHIND A SINGLE SWITCH FACEPLATE.
G CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF MECHANICAL
EQUIPMENT WITH THE MECHANICAL CONTRACTOR. EXACT ELECTRICAL
REQUIREMENTS SHALL BE FIELD VERIFIED AGAINST THE EQUIPMENT NAME
PLATE DATA. THE CONTRACTOR SHALL MAKE APPROPRIATE ADJUSTMENTS
OF FEEDER CIRCUIT CONDUCTORS AND OVERCURRENT PROTECTION PER
MANUFACTURER.
H ALL RECEPTACLES LOCATED IN KITCHENS AND BATHROOMS SHALL BE GFCI
TYPE.
I LOAD CENTERS FOR EACH DWELLING UNIT SHALL BE RECESSED IN WALL AS
INDICATED. LOAD CENTER SHALL NOT BE INSTALLED IN DEMISING WALL.
J PROVIDE DUPLEX RECEPTACLE ON DEDICATED CIRCUIT IN
HOMENETWORKING CABINET.
K ALL SMOKE ALARM DEVICES WITHIN EACH DWELLING UNIT SHALL BE
INTERCONNECTED AND ONLY ALARM WITHIN THE DWELLING UNIT THEY
RESIDE.
L THE BUILDING FIRE ALARM CONTROL PANEL SHALL MONITOR THE STATUS
OF EACH SMOKE ALARM UNIT WITHIN EACH DWELLING UNIT.
M DWELLING UNIT SMOKE ALARM DEVICES SHALL BE POWERED BY THE
BUILDING FIRE ALARM SYSTEM.
N PROVIDE LOW FREQUENCY AUDIBLE DEVICE WITHIN EACH SLEEPING AREA
AND LIVING AREA AS INDICATED ON EACH DWELLING UNIT TYPE. AUDIBLE
DEVICES SHALL ALARM UPON ACTIVATION OF BUILDING FIRE ALARM
SYSTEM AND DWELLING UNIT SMOKE ALARM DEVICES.
O DWELLING UNITS NOTED AS ADA ACCESSIBLE SHALL BE EQUIPPED WITH
FIRE ALARM VISUAL DEVICES WITHIN BEDROOMS, BATHROOMS AND
COMMON LIVING AREAS AS NOTED ON PLANS.
P DWELLING UNITS NOTED AS ADA ACCESSIBLE ELECTRICAL PANELS SHALL
BE MOUNTED SO AS THE HIGHEST BREAKER IS NO HIGHER THAN 48" ABOVE
FINISHED FLOOR
# DESCRIPTION DATE
1 BID DOCUMENT 01/15/2021
SWITCHING SCHEDULE
TYPE 1ST SWITCH TYPE 1ST SWITCH FUNCTION 2ND SWITCH TYPE 2ND SWITCH FUNCTION 3RD SWITCH TYPE 3RD SWITCH FUNCTION 4TH SWITCH TYPE 4TH SWITCH FUNCTION
A SNAP ENTRY A3 FIXTURE SNAP KITCHEN A3 FIXTURES SNAP KITCHEN A4 FIXTURES
B SNAP DINING A3 FIXTURES SNAP HALLWAY A3 FIXTURE
C SNAP LIVING A3 FIXTURES SNAP BALCONY A5 FIXTURE
D DUAL-SLIDE BEDROOM A2 CEILING FIXTURE SNAP BEDROOM SWITCHED RECEPTACLE
E SNAP RESTROOM FIXTURES SNAP RESTROOM EXHAUST FAN
F SNAP CLOSET A3 FIXTURE
G SNAP LIVING A3 FIXTURES SNAP DINING A3 FIXTURES SNAP BALCONY A5 FIXTURE
H SNAP HALLWAY A3 FIXTURE
I THREE-WAY SNAP HALLWAY A3 FIXTURE
J THREE-WAY SNAP ENTRY A3 FIXTURE
K SNAP DINING A3 FIXTURES SNAP BALCONY A5 FIXTURE
L SNAP LIVING A3 FIXTURES SNAP HALLWAY A3 FIXTURE
M SNAP ENTRY A3 FIXTURE SNAP HALLWAY A3 FIXTURE
N SNAP KITCHEN A3 FIXTURES SNAP KITCHEN A4 FIXTURES
O SNAP LIVING A3 FIXTURES
1/4" = 1'-0"
UNIT B3b ELECTRICAL PLAN4 1/4" = 1'-0"
UNIT B3 ELECTRICAL PLAN2
1
07/08/21