HomeMy WebLinkAboutEP114a - BUILDING ELECTRICAL PLANS - BUILDING AHP-2 HP-2 HP-1HP-1 HP-1 HP-1 HP-2 HP-2 HP-1 HP-1 HP-2 HP-2 HP-2 HP-2 HP-2 HP-2 HP-2 HP-2 HP-2HP-2 HP-1 HP-1 HP-1 HP-1HP-1HP-1 HP-2 HP-2 HP-2 HP-2 HP-2 HP-2 WP WPWP WP WP WP HA3-9 HA3-9 HA3-9 HA3-9 HA3-9 HA3-9 HA3-11,13 HA3-15,17 1 2 3 PEV-1 HP-1 HP-1 1 1 1 1 HA3-204 2 2 2 2 2 2 2 2 2 22 2 2 2 2 22 22 22 HA3-21,23 HA3-22,24 2 2 2 2 2 2 3 3 3 ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031 JANUARY 15, 2021 BID SET EP114aBUILDING ELECTRICALPLANS -BUILDING ANORTH ENDAPARTMENTSCARMEL, INSHEET KEYNOTES 1 PROVIDE WEATHER PROOF WHILE IN USE GFI PROTECTED RECEPTACLE. COORDINATE MOUNTING LOCATION WITH EQUIPMENT BEING PROVIDED. 2 REFER TO E400 SERIES DRAWINGS FOR CIRCUITING INFORMATION TO CONDENSING UNIT. 3 PROVIDE ELECTRICAL CONNECTION AND DISCONNECT FOR CONDENSING UNIT. 4 PROVIDE CONNECTION TO PEV-1. COORDINATE EXACT REQUIREMENTS WITH EQUIPMENT BEING PROVIDED. 1/8" = 1'-0" BUILDING A ELECTRICAL ROOF PLAN - AREA A1 GENERAL NOTES A REFER TO SHEET E-000 FOR GENERAL ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFER TO E-600 SERIES SHEETS FOR LOAD CENTER CIRCUIT SCHEDULES FOR EACH DWELLNG UNIT TYPE. C TO PROVIDE (1) 1" CONDUIT WITH PULL STRING AND BUSHINGS FROM TERMINAL BOARD TO EACH APARTMENT UNIT HOME NETWORKING ENCLOSURE. COORDINATE WITH UTILITY ON EXACT REQUIREMENTS PRIOR TO ROUHG-IN. # DESCRIPTION DATE 07/08/21