Loading...
HomeMy WebLinkAboutLS111b - BUILDING A - FIRST FLOOR CODE PLAN - AREA BCODE PLAN GRAPHICS LEGEND 1. ATTIC DRAFTSTOPPING, SEE A340 SERIES. DRAFTSTOPPING TO EXTEND HORIZONTALLY TO INCLUDE EAVE/SOFFIT. INDIVIDUAL AREAS OF SEPARATION BETWEEN DRAFTSTOPPING NOT TO EXCEED 3,000SF. PROVIDE ACCESS DOOR, 24"X30" MIN., FOR EACH AREA OF SEPARATION AS INDICATED. 2. DASHED LINE REPRESENTS CENTER OF 2-HOUR FIRE WALL BELOW. PROVIDE MINIMUM OF 4'-0" OF FIRE RETARDENT ROOF SHEATHING ON BOTH SIDES. 3. UNIT DEMISING WALLS BETWEEN UNITS TO BE 1 -HOUR FIRE PARTITIONS PER IBC 708. SEE A340 SERIES. 4. CORRIDOR WALLS TO BE 1 -HOUR FIRE PARTITIONS PER IBC 708. SEE A340 SERIES. 5. ELEVATOR SHAFTS AND INTERIOR EXIT STAIRWAYS TO BE 2-HOUR FIRE BARRIERS PER IBC 707. SEE A160 SERIES. 6. MECHANICAL SHAFTS TO BE 2-HOUR FIRE BARRIERS PER IBC 707. SEE A340 SERIES. 7. LOWER LEVEL GARAGES TO BE SEPARATED FROM AREAS ABOVE WITH 3-HOUR RATED PODIUM. RETAIL/COMMERCIAL SPACE IN BUILDING A TO ALSO BE SEPARATED FROM AREAS ABOVE WITH 3-HOUR RATED PODIUM. 8. DRAFSTOPPING SHALL BE PROVIDED IN FLOOR/CEILING AND ROOF/CEILING SPACES PER SECTION 718. 9. 20"X30" MIN. ATTIC ACCESS PANEL. 10. 20"X40" SELF-CLOSING ATTIC ACCESS DOOR THROUGH DRAFSTOPPING. CODE PLAN NOTES # NON-RATED ASSEMBLY 1 HR RATED ASSEMBLY 2 HR RATED ASSEMBLY 2 HR FIRE WALL DRAFT STOP LOCATION FIRE EXSTINGUISHER CABINET DIRECTION OF TRAVEL 31 0 0" EXIT OCCUPANT LOAD THROUGH EXIT EGRESS WIDTH ALLOWABLE NUMBER OF OCCUPANTS THROUGH EXIT LOAD FACTOR KEY R - RESIDENTIAL - 200 GROSS B - BUSINESS - 100 GROSS S - STORAGE - 300 GROSS STAIR WIDTH = X DOOR WIDTH = X xxx STAIR WIDTH FACTOR 0.20" PER OCCUPANT DOOR WIDTH FACTOR 0.15" PER OCCUPANT EGRESS CAPACITY OF STAIR R-2 210SF ROOM # 1202 1 OCCUPANCY GROUP ROOM IDENTIFICATION ROOM AREA NUMBER OF EXITS REQUIRED OCCUPANT LOAD FACTOR NUMBER OF OCCUPANTS FEC 2-HR FW A - ASSEMBLY - 15 GROSS E - EXERCISE - 50 GROSS U - GARAGE - 200 GROSS 162 1 / LS111a 1 / LS111a DOOR WIDTH = 34" 120 STAIR WIDTH = 36" 227 34" 6557SF 98 B OFFICE 102 100 1 F.E.C. F.E.C. 1711SF 115 A AMENITIES C008 15 3 108SF 2 B OFFICE C001 100 1 112SF 2 B OFFICE C002 100 1 91SF 1 B WORK ROOM C004 100 1 135SF 1 B MAIL ROOM C010 100 1 24 227 34" 4 227 34" 24 25 227 34" 25 227 34" 227 34" 314SF 4 S-2 BIKE ROOM C009 100 1 (98) TOTAL OCCUPANCY (124) AMENITIES TOTAL OCCUPANCY 13SF 1 S-2 STOR. C003 300 1 55SF 1 S-2 MECH. ROOM M101 300 1 57SF 1 S-2 RESTROOM C006 300 1 57SF 1 S-2 RESTROOM C007 300 1 98 227 34" MAX. TRAVE L DIST A N CE = 88'-0" 25 227 34" 25 227 34" AREA A AREA B FIRE AREA DIAGRAM - BUILDING A GARAGE - TYPE IA CODE BLDG SECTION BUILDING A COMMERCIAL - TYPE IA RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA 3-HOUR RATED 3-HOUR RATED 1 -HOUR RATED 1 -HOUR RATED GARAGE - TYPE IA CODE BLDG SECTION BUILDING B RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA 3-HOUR RATED 1 -HOUR RATED 1 -HOUR RATED 1 -HOUR RATED 1 -HOUR RATED CODE BLDG SECTION BUILDING C RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA 1 -HOUR RATED 1 -HOUR RATED 1 -HOUR RATED RESIDENTIAL - TYPE VA 1 -HOUR RATED ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031 JANUARY 15, 2021 BID DOCUMENTS LS111bBUILDING A - FIRSTFLOOR CODE PLAN -AREA BNORTH ENDAPARTMENTSCARMEL, INSCALE: 1/8" = 1'-0"1 BUILDING A -FIRST FLOOR CODE PLAN -AREA B BUILDING A TOTAL OCCUPANCY: LOWER LEVEL 89 1ST FLOOR 399 2ND FLOOR 146 3RD FLOOR 146 TOTAL: 780 # DESCRIPTION DATE 04/15/22