HomeMy WebLinkAboutLS111b - BUILDING A - FIRST FLOOR CODE PLAN - AREA BCODE PLAN GRAPHICS LEGEND
1. ATTIC DRAFTSTOPPING, SEE A340 SERIES. DRAFTSTOPPING TO
EXTEND HORIZONTALLY TO INCLUDE EAVE/SOFFIT. INDIVIDUAL
AREAS OF SEPARATION BETWEEN DRAFTSTOPPING NOT TO
EXCEED 3,000SF. PROVIDE ACCESS DOOR, 24"X30" MIN., FOR
EACH AREA OF SEPARATION AS INDICATED.
2. DASHED LINE REPRESENTS CENTER OF 2-HOUR FIRE WALL BELOW.
PROVIDE MINIMUM OF 4'-0" OF FIRE RETARDENT ROOF SHEATHING
ON BOTH SIDES.
3. UNIT DEMISING WALLS BETWEEN UNITS TO BE 1 -HOUR FIRE
PARTITIONS PER IBC 708. SEE A340 SERIES.
4. CORRIDOR WALLS TO BE 1 -HOUR FIRE PARTITIONS PER IBC 708.
SEE A340 SERIES.
5. ELEVATOR SHAFTS AND INTERIOR EXIT STAIRWAYS TO BE 2-HOUR
FIRE BARRIERS PER IBC 707. SEE A160 SERIES.
6. MECHANICAL SHAFTS TO BE 2-HOUR FIRE BARRIERS PER IBC
707. SEE A340 SERIES.
7. LOWER LEVEL GARAGES TO BE SEPARATED FROM AREAS ABOVE
WITH 3-HOUR RATED PODIUM. RETAIL/COMMERCIAL SPACE IN
BUILDING A TO ALSO BE SEPARATED FROM AREAS ABOVE WITH
3-HOUR RATED PODIUM.
8. DRAFSTOPPING SHALL BE PROVIDED IN FLOOR/CEILING AND
ROOF/CEILING SPACES PER SECTION 718.
9. 20"X30" MIN. ATTIC ACCESS PANEL.
10. 20"X40" SELF-CLOSING ATTIC ACCESS DOOR THROUGH
DRAFSTOPPING.
CODE PLAN NOTES #
NON-RATED ASSEMBLY
1 HR RATED ASSEMBLY
2 HR RATED ASSEMBLY
2 HR FIRE WALL
DRAFT STOP LOCATION
FIRE EXSTINGUISHER CABINET
DIRECTION OF TRAVEL
31 0
0"
EXIT
OCCUPANT LOAD
THROUGH EXIT
EGRESS WIDTH
ALLOWABLE NUMBER
OF OCCUPANTS
THROUGH EXIT
LOAD FACTOR KEY
R - RESIDENTIAL - 200 GROSS
B - BUSINESS - 100 GROSS
S - STORAGE - 300 GROSS
STAIR WIDTH = X
DOOR WIDTH = X
xxx
STAIR WIDTH FACTOR
0.20" PER OCCUPANT
DOOR WIDTH FACTOR
0.15" PER OCCUPANT
EGRESS CAPACITY OF
STAIR
R-2 210SF
ROOM
#
1202 1
OCCUPANCY
GROUP
ROOM IDENTIFICATION
ROOM AREA
NUMBER OF EXITS
REQUIRED
OCCUPANT LOAD
FACTOR
NUMBER OF
OCCUPANTS
FEC
2-HR FW
A - ASSEMBLY - 15 GROSS
E - EXERCISE - 50 GROSS
U - GARAGE - 200 GROSS
162
1 / LS111a 1 / LS111a
DOOR WIDTH = 34"
120
STAIR WIDTH = 36"
227
34"
6557SF
98
B
OFFICE
102
100 1
F.E.C.
F.E.C.
1711SF
115
A
AMENITIES
C008
15 3
108SF
2
B
OFFICE
C001
100 1
112SF
2
B
OFFICE
C002
100 1
91SF
1
B
WORK ROOM
C004
100 1
135SF
1
B
MAIL ROOM
C010
100 1
24
227
34"
4
227
34"
24
25
227
34"
25
227
34"
227
34"
314SF
4
S-2
BIKE ROOM
C009
100 1
(98) TOTAL OCCUPANCY
(124) AMENITIES TOTAL OCCUPANCY
13SF
1
S-2
STOR.
C003
300 1
55SF
1
S-2
MECH. ROOM
M101
300 1
57SF
1
S-2
RESTROOM
C006
300 1 57SF
1
S-2
RESTROOM
C007
300 1
98
227
34"
MAX. TRAVE L DIST
A
N
CE = 88'-0"
25
227
34"
25
227
34"
AREA A
AREA B
FIRE AREA DIAGRAM - BUILDING A
GARAGE - TYPE IA
CODE BLDG SECTION
BUILDING A
COMMERCIAL - TYPE IA
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
3-HOUR
RATED
3-HOUR
RATED
1 -HOUR
RATED
1 -HOUR
RATED
GARAGE - TYPE IA
CODE BLDG SECTION
BUILDING B
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
3-HOUR
RATED
1 -HOUR
RATED
1 -HOUR
RATED
1 -HOUR
RATED
1 -HOUR
RATED
CODE BLDG SECTION
BUILDING C
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
1 -HOUR
RATED
1 -HOUR
RATED
1 -HOUR
RATED
RESIDENTIAL - TYPE VA
1 -HOUR
RATED
ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031
JANUARY 15, 2021
BID DOCUMENTS
LS111bBUILDING A - FIRSTFLOOR CODE PLAN -AREA BNORTH ENDAPARTMENTSCARMEL, INSCALE: 1/8" = 1'-0"1 BUILDING A -FIRST FLOOR CODE PLAN -AREA B
BUILDING A TOTAL OCCUPANCY:
LOWER LEVEL 89
1ST FLOOR 399
2ND FLOOR 146
3RD FLOOR 146
TOTAL: 780
# DESCRIPTION DATE