Loading...
HomeMy WebLinkAboutLS112a - BUILDING A - UPPER FLOOR CODE PLAN - AREA ACODE PLAN GRAPHICS LEGEND 1. ATTIC DRAFTSTOPPING, SEE A340 SERIES. DRAFTSTOPPING TO EXTEND HORIZONTALLY TO INCLUDE EAVE/SOFFIT. INDIVIDUAL AREAS OF SEPARATION BETWEEN DRAFTSTOPPING NOT TO EXCEED 3,000SF. PROVIDE ACCESS DOOR, 24"X30" MIN., FOR EACH AREA OF SEPARATION AS INDICATED. 2. DASHED LINE REPRESENTS CENTER OF 2-HOUR FIRE WALL BELOW. PROVIDE MINIMUM OF 4'-0" OF FIRE RETARDENT ROOF SHEATHING ON BOTH SIDES. 3. UNIT DEMISING WALLS BETWEEN UNITS TO BE 1 -HOUR FIRE PARTITIONS PER IBC 708. SEE A340 SERIES. 4. CORRIDOR WALLS TO BE 1 -HOUR FIRE PARTITIONS PER IBC 708. SEE A340 SERIES. 5. ELEVATOR SHAFTS AND INTERIOR EXIT STAIRWAYS TO BE 2-HOUR FIRE BARRIERS PER IBC 707. SEE A160 SERIES. 6. MECHANICAL SHAFTS TO BE 2-HOUR FIRE BARRIERS PER IBC 707. SEE A340 SERIES. 7. LOWER LEVEL GARAGES TO BE SEPARATED FROM AREAS ABOVE WITH 3-HOUR RATED PODIUM. RETAIL/COMMERCIAL SPACE IN BUILDING A TO ALSO BE SEPARATED FROM AREAS ABOVE WITH 3-HOUR RATED PODIUM. 8. DRAFSTOPPING SHALL BE PROVIDED IN FLOOR/CEILING AND ROOF/CEILING SPACES PER SECTION 718. 9. 20"X30" MIN. ATTIC ACCESS PANEL. 10. 20"X40" SELF-CLOSING ATTIC ACCESS DOOR THROUGH DRAFSTOPPING. CODE PLAN NOTES # NON-RATED ASSEMBLY 1 HR RATED ASSEMBLY 2 HR RATED ASSEMBLY 2 HR FIRE WALL DRAFT STOP LOCATION FIRE EXSTINGUISHER CABINET DIRECTION OF TRAVEL 31 0 0" EXIT OCCUPANT LOAD THROUGH EXIT EGRESS WIDTH ALLOWABLE NUMBER OF OCCUPANTS THROUGH EXIT LOAD FACTOR KEY R - RESIDENTIAL - 200 GROSS B - BUSINESS - 100 GROSS S - STORAGE - 300 GROSS STAIR WIDTH = X DOOR WIDTH = X xxx STAIR WIDTH FACTOR 0.20" PER OCCUPANT DOOR WIDTH FACTOR 0.15" PER OCCUPANT EGRESS CAPACITY OF STAIR R-2 210SF ROOM # 1202 1 OCCUPANCY GROUP ROOM IDENTIFICATION ROOM AREA NUMBER OF EXITS REQUIRED OCCUPANT LOAD FACTOR NUMBER OF OCCUPANTS FEC 2-HR FW A - ASSEMBLY - 15 GROSS E - EXERCISE - 50 GROSS U - GARAGE - 200 GROSS 2-HR FW2-HR FW 2-HR FW 1 / LS112b 1 / LS112b UNIT B2 202 1202SF 200 R2 16 UNIT A1 204 831SF 200 R2 15 UNIT B1 206 1209SF 200 R2 16 UNIT B1 208 1209SF 200 R2 16 UNIT A2 210 828SF 200 R2 15 UNIT A1 212 831SF 200 R2 15 UNIT B3 217 1312SF 200 R2 17 UNIT B2 201 1202SF 200 R2 16 UNIT A4 203 904SF 200 R2 15 UNIT A1 205 831SF 200 R2 15 UNIT B1 211 1209SF 200 R2 16 UNIT A5 213 1202SF 200 R2 16 UNIT B2 215 1202SF 200 R2 16 68SF 1 S-2 ELEC. ROOM E201 300 1 81SF 1 S-2 STORAGE S201 300 1 73SF 1 S-2 MECH. ROOM M201 300 1 74SF 1 S-2 ELEC. ROOM E202 300 1 97SF 1 S-2 MECH. ROOM M202 300 1 DOOR WIDTH = 34" 120 STAIR WIDTH = 36" DOOR WIDTH = 34" 120 STAIR WIDTH = 36" 46 227 34" 73 27 227 34" F.E.C. MAX. TRAVEL DISTANCE = 176'-6" (92) TOTAL OCCUPANCY UNIT B1 207 1209SF 200 R2 16 UNIT B1 209 1209SF 200 R2 16 F.E.C. F.E.C. F.E.C. 9 103SF 1 S-2 STORAGE S202 300 1 AREA A AREA B FIRE AREA DIAGRAM - BUILDING A GARAGE - TYPE IA CODE BLDG SECTION BUILDING A COMMERCIAL - TYPE IA RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA 3-HOUR RATED 3-HOUR RATED 1 -HOUR RATED 1 -HOUR RATED GARAGE - TYPE IA CODE BLDG SECTION BUILDING B RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA 3-HOUR RATED 1 -HOUR RATED 1 -HOUR RATED 1 -HOUR RATED 1 -HOUR RATED CODE BLDG SECTION BUILDING C RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA 1 -HOUR RATED 1 -HOUR RATED 1 -HOUR RATED RESIDENTIAL - TYPE VA 1 -HOUR RATED ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031 JANUARY 15, 2021 BID DOCUMENTS LS112aBUILDING A - UPPERFLOOR CODE PLAN -AREA ANORTH ENDAPARTMENTSCARMEL, INSCALE: 1/8" = 1'-0"1 BUILDING A -UPPER FLOOR CODE PLAN -AREA A BUILDING A TOTAL OCCUPANCY: LOWER LEVEL 89 1ST FLOOR 399 2ND FLOOR 146 3RD FLOOR 146 TOTAL: 780 # DESCRIPTION DATE 04/15/22