HomeMy WebLinkAboutLS122 - BUILDING B - UPPER FLOOR CODE PLANCODE PLAN GRAPHICS LEGEND
1. ATTIC DRAFTSTOPPING, SEE A340 SERIES. DRAFTSTOPPING TO
EXTEND HORIZONTALLY TO INCLUDE EAVE/SOFFIT. INDIVIDUAL
AREAS OF SEPARATION BETWEEN DRAFTSTOPPING NOT TO
EXCEED 3,000SF. PROVIDE ACCESS DOOR, 24"X30" MIN., FOR
EACH AREA OF SEPARATION AS INDICATED.
2. DASHED LINE REPRESENTS CENTER OF 2-HOUR FIRE WALL BELOW.
PROVIDE MINIMUM OF 4'-0" OF FIRE RETARDENT ROOF SHEATHING
ON BOTH SIDES.
3. UNIT DEMISING WALLS BETWEEN UNITS TO BE 1 -HOUR FIRE
PARTITIONS PER IBC 708. SEE A340 SERIES.
4. CORRIDOR WALLS TO BE 1 -HOUR FIRE PARTITIONS PER IBC 708.
SEE A340 SERIES.
5. ELEVATOR SHAFTS AND INTERIOR EXIT STAIRWAYS TO BE 2-HOUR
FIRE BARRIERS PER IBC 707. SEE A160 SERIES.
6. MECHANICAL SHAFTS TO BE 2-HOUR FIRE BARRIERS PER IBC
707. SEE A340 SERIES.
7. LOWER LEVEL GARAGES TO BE SEPARATED FROM AREAS ABOVE
WITH 3-HOUR RATED PODIUM. RETAIL/COMMERCIAL SPACE IN
BUILDING A TO ALSO BE SEPARATED FROM AREAS ABOVE WITH
3-HOUR RATED PODIUM.
8. DRAFSTOPPING SHALL BE PROVIDED IN FLOOR/CEILING AND
ROOF/CEILING SPACES PER SECTION 718.
9. 20"X30" MIN. ATTIC ACCESS PANEL.
10. 20"X40" SELF-CLOSING ATTIC ACCESS DOOR THROUGH
DRAFSTOPPING.
CODE PLAN NOTES #
NON-RATED ASSEMBLY
1 HR RATED ASSEMBLY
2 HR RATED ASSEMBLY
2 HR FIRE WALL
DRAFT STOP LOCATION
FIRE EXSTINGUISHER CABINET
DIRECTION OF TRAVEL
31 0
0"
EXIT
OCCUPANT LOAD
THROUGH EXIT
EGRESS WIDTH
ALLOWABLE NUMBER
OF OCCUPANTS
THROUGH EXIT
LOAD FACTOR KEY
R - RESIDENTIAL - 200 GROSS
B - BUSINESS - 100 GROSS
S - STORAGE - 300 GROSS
STAIR WIDTH = X
DOOR WIDTH = X
xxx
STAIR WIDTH FACTOR
0.20" PER OCCUPANT
DOOR WIDTH FACTOR
0.15" PER OCCUPANT
EGRESS CAPACITY OF
STAIR
R-2 210SF
ROOM
#
1202 1
OCCUPANCY
GROUP
ROOM IDENTIFICATION
ROOM AREA
NUMBER OF EXITS
REQUIRED
OCCUPANT LOAD
FACTOR
NUMBER OF
OCCUPANTS
FEC
2-HR FW
A - ASSEMBLY - 15 GROSS
E - EXERCISE - 50 GROSS
U - GARAGE - 200 GROSS
DOOR WIDTH = 34"
153
STAIR WIDTH = 46"
DOOR WIDTH = 34"
153
STAIR WIDTH = 46"
UNIT B2
202
UNIT A4
204
UNIT A1
IDD
206
UNIT A2
208
UNIT A2
210
UNIT A1
IDD
206
UNIT B2
201
UNIT A1
205
UNIT A2
207
UNIT A2
209
UNIT A1
IDD
206
UNIT A4
213
UNIT B2
215
1202SF
200
R2 1 6
904SF
200
R2 15
831SF
200
R2 15
828SF
200
R2 15
828SF
200
R2 15
831SF
200
R2 1 5
1202SF
200
R2 1 6
831SF
200
R2 15
828SF
200
R2 15
828SF
200
R2 15
831SF
200
R2 15
904SF
200
R2 15
1202SF
200
R2 16
UNIT B2
216
1202SF
200
R2 16
88SF
1
S-2
ELEC. ROOM
E201
300 1
53SF
1
S-2
MECH. ROOM
M201
300 1
88SF
1
S-2
ELEC. ROOM
E202
300 1
53SF
1
S-2
MECH. ROOM
M202
300 1
39
39
MAX. TRAVEL DISTANCE = 140'-0"
(78) TOTAL OCCUPANCY
F.E.C.
F.E.C. F.E.C.
F.E.C.
6
5
6
5
5 5
3
TYP.
4
9
9
9
9
GARAGE - TYPE IA
CODE BLDG SECTION
BUILDING A
COMMERCIAL - TYPE IA
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
3-HOUR
RATED
3-HOUR
RATED
1 -HOUR
RATED
1 -HOUR
RATED
GARAGE - TYPE IA
CODE BLDG SECTION
BUILDING B
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
3-HOUR
RATED
1 -HOUR
RATED
1 -HOUR
RATED
1 -HOUR
RATED
1 -HOUR
RATED
CODE BLDG SECTION
BUILDING C
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
RESIDENTIAL - TYPE VA
1 -HOUR
RATED
1 -HOUR
RATED
1 -HOUR
RATED
RESIDENTIAL - TYPE VA
1 -HOUR
RATED
ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031
JANUARY 15, 2021
BID DOCUMENTS
LS122BUILDING B - UPPERFLOOR CODE PLANNORTH ENDAPARTMENTSCARMEL, INSCALE: 1/8" = 1'-0"1 BUILDING B -UPPER FLOOR CODE PLAN
BUILDING B TOTAL OCCUPANCY:
LOWER LEVEL 74
1ST FLOOR 130
2ND FLOOR 78
3RD FLOOR 78
4TH FLOOR 78
TOTAL: 438
# DESCRIPTION DATE
04/15/22