Loading...
HomeMy WebLinkAboutLS122 - BUILDING B - UPPER FLOOR CODE PLANCODE PLAN GRAPHICS LEGEND 1. ATTIC DRAFTSTOPPING, SEE A340 SERIES. DRAFTSTOPPING TO EXTEND HORIZONTALLY TO INCLUDE EAVE/SOFFIT. INDIVIDUAL AREAS OF SEPARATION BETWEEN DRAFTSTOPPING NOT TO EXCEED 3,000SF. PROVIDE ACCESS DOOR, 24"X30" MIN., FOR EACH AREA OF SEPARATION AS INDICATED. 2. DASHED LINE REPRESENTS CENTER OF 2-HOUR FIRE WALL BELOW. PROVIDE MINIMUM OF 4'-0" OF FIRE RETARDENT ROOF SHEATHING ON BOTH SIDES. 3. UNIT DEMISING WALLS BETWEEN UNITS TO BE 1 -HOUR FIRE PARTITIONS PER IBC 708. SEE A340 SERIES. 4. CORRIDOR WALLS TO BE 1 -HOUR FIRE PARTITIONS PER IBC 708. SEE A340 SERIES. 5. ELEVATOR SHAFTS AND INTERIOR EXIT STAIRWAYS TO BE 2-HOUR FIRE BARRIERS PER IBC 707. SEE A160 SERIES. 6. MECHANICAL SHAFTS TO BE 2-HOUR FIRE BARRIERS PER IBC 707. SEE A340 SERIES. 7. LOWER LEVEL GARAGES TO BE SEPARATED FROM AREAS ABOVE WITH 3-HOUR RATED PODIUM. RETAIL/COMMERCIAL SPACE IN BUILDING A TO ALSO BE SEPARATED FROM AREAS ABOVE WITH 3-HOUR RATED PODIUM. 8. DRAFSTOPPING SHALL BE PROVIDED IN FLOOR/CEILING AND ROOF/CEILING SPACES PER SECTION 718. 9. 20"X30" MIN. ATTIC ACCESS PANEL. 10. 20"X40" SELF-CLOSING ATTIC ACCESS DOOR THROUGH DRAFSTOPPING. CODE PLAN NOTES # NON-RATED ASSEMBLY 1 HR RATED ASSEMBLY 2 HR RATED ASSEMBLY 2 HR FIRE WALL DRAFT STOP LOCATION FIRE EXSTINGUISHER CABINET DIRECTION OF TRAVEL 31 0 0" EXIT OCCUPANT LOAD THROUGH EXIT EGRESS WIDTH ALLOWABLE NUMBER OF OCCUPANTS THROUGH EXIT LOAD FACTOR KEY R - RESIDENTIAL - 200 GROSS B - BUSINESS - 100 GROSS S - STORAGE - 300 GROSS STAIR WIDTH = X DOOR WIDTH = X xxx STAIR WIDTH FACTOR 0.20" PER OCCUPANT DOOR WIDTH FACTOR 0.15" PER OCCUPANT EGRESS CAPACITY OF STAIR R-2 210SF ROOM # 1202 1 OCCUPANCY GROUP ROOM IDENTIFICATION ROOM AREA NUMBER OF EXITS REQUIRED OCCUPANT LOAD FACTOR NUMBER OF OCCUPANTS FEC 2-HR FW A - ASSEMBLY - 15 GROSS E - EXERCISE - 50 GROSS U - GARAGE - 200 GROSS DOOR WIDTH = 34" 153 STAIR WIDTH = 46" DOOR WIDTH = 34" 153 STAIR WIDTH = 46" UNIT B2 202 UNIT A4 204 UNIT A1 IDD 206 UNIT A2 208 UNIT A2 210 UNIT A1 IDD 206 UNIT B2 201 UNIT A1 205 UNIT A2 207 UNIT A2 209 UNIT A1 IDD 206 UNIT A4 213 UNIT B2 215 1202SF 200 R2 1 6 904SF 200 R2 15 831SF 200 R2 15 828SF 200 R2 15 828SF 200 R2 15 831SF 200 R2 1 5 1202SF 200 R2 1 6 831SF 200 R2 15 828SF 200 R2 15 828SF 200 R2 15 831SF 200 R2 15 904SF 200 R2 15 1202SF 200 R2 16 UNIT B2 216 1202SF 200 R2 16 88SF 1 S-2 ELEC. ROOM E201 300 1 53SF 1 S-2 MECH. ROOM M201 300 1 88SF 1 S-2 ELEC. ROOM E202 300 1 53SF 1 S-2 MECH. ROOM M202 300 1 39 39 MAX. TRAVEL DISTANCE = 140'-0" (78) TOTAL OCCUPANCY F.E.C. F.E.C. F.E.C. F.E.C. 6 5 6 5 5 5 3 TYP. 4 9 9 9 9 GARAGE - TYPE IA CODE BLDG SECTION BUILDING A COMMERCIAL - TYPE IA RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA 3-HOUR RATED 3-HOUR RATED 1 -HOUR RATED 1 -HOUR RATED GARAGE - TYPE IA CODE BLDG SECTION BUILDING B RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA 3-HOUR RATED 1 -HOUR RATED 1 -HOUR RATED 1 -HOUR RATED 1 -HOUR RATED CODE BLDG SECTION BUILDING C RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA RESIDENTIAL - TYPE VA 1 -HOUR RATED 1 -HOUR RATED 1 -HOUR RATED RESIDENTIAL - TYPE VA 1 -HOUR RATED ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031 JANUARY 15, 2021 BID DOCUMENTS LS122BUILDING B - UPPERFLOOR CODE PLANNORTH ENDAPARTMENTSCARMEL, INSCALE: 1/8" = 1'-0"1 BUILDING B -UPPER FLOOR CODE PLAN BUILDING B TOTAL OCCUPANCY: LOWER LEVEL 74 1ST FLOOR 130 2ND FLOOR 78 3RD FLOOR 78 4TH FLOOR 78 TOTAL: 438 # DESCRIPTION DATE 04/15/22