Loading...
HomeMy WebLinkAboutM111b - BUILDING MECHANICAL PLANS - BUILDING AUH-1 SG1SG1 -100 8ø 16ø 10ø 8ø SG2SG2 -200 SG2SG2 -200 SG1SG1 -100 SG1SG1 -100 SG1SG1 -100 SG1SG1 -100SG1SG1 -100 SG1SG1 -100 SG1SG1 -100 12ø 10ø SG2SG2 -100 SG1SG1 -100SG1SG1 -100 6ø 10/6 8ø 10ø SG2SG2 -200 SG1SG1 -100 FCU-5 RG3 EF-1 EF-1 MAIL ROOM C010 AMENITIES C008 ST3-1 ST3-1 ELV2-1 ELV2-1 OFFICE 102 UH-1 BIKE ROOM C009 RG4 30/14 12/810ø 3 M404 UH-1 1 1 1 2 3 4 360 CFM 4 5 5 6 6 ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031 JANUARY 15, 2021 BID SET M111bBUILDING MECHANICALPLANS -BUILDING ANORTH ENDAPARTMENTSCARMEL, INGENERAL NOTES A REFER TO SHEET M000 FOR GENERAL MECHANICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFERENCE M501 SERIES FOR MECHANICAL DETAILS. C REFERENCE M601 SERIES FOR MECHANICAL SCHEDULES. D COORDINATE WITH STRUCTURAL AND FRAMING PLANS PRIOR TO COMMENCING WORK. COORDINATE ALL ROUTING WITH ALL TRADES PRIOR TO FABRICATION. E SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND TYPES OF RATED CONSTRUCTION TO MAINTAIN CONSTRUCTION RATING. F THERMOSTATS TO BE 44" A.F.F. OR ALIGNED TO ADJACENT SWITCHES UNLESS OTHERWISE NOTED. G SEAL ALL FLOOR, CEILING, AND WALL PENETRATIONS. USE FIRE CAULK AT RATED ASSEMBLIES AND GENERAL SEALANT ELSEWHERE. WHERE NON-METALLIC COMPONENTS LARGER THAN 4"Ø (I.E. PVC OR CONDUIT) PENETRATES RATED ASSEMBLIES, INSTALL INTUMESCENT COLLAR. WHERE DUCTWORK LARGER THAN 4"Ø PENETRATES RATED ASSEMBLIES, INSTALL FIRE DAMPER. H SIZE AND INSTALL REFRIGERANT PIPING AND ACCESSORIES PER MANUFACTURES RECOMMENDATIONS. I ALL EXTERIOR VENT CAP AND VENT HOOD COLORS TO BE VERIFIED IN SHOP DRAWINGS. J ALL FAN COIL UNITS TO BE WALL MOUNTED UNLESS OTHERWISE INDICATED. COORDINATE MOUNTING HEIGHT WITH OTHER DISCIPLINES AND SPACE. K THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A SIGN ATTACHED TO THE DRYER BOX IN EACH APARTMENT. THE TAG SHALL DOCUMENT THE ASSOCIATED INSTALLED DRYER VENT AND READ AS FOLLOWS: CONNECTED VENT DUCT: STRAIGHT DUCT: X FEET 90 DEG. ELBOW: COUNT=X 45 DEGREE ELBOWS: COUNT=X L PROVIDE MECHANICAL SYSTEMS IN COMPLIANCE WITH STATE AND LOCAL CODES. M DRYER AND BATHROOM EXHAUST DUCTWORK TO BE MINIMUM 28 GAUGE. N ALL HVAC SUPPLY REGISTERS, RETURN GRILLES AND DUCT TERMINATIONS ARE TO BE PROTECTED DURING CONSTRUCTION ACTIVITIES AGAINST THE INTRODUCTION OF DUST AND POLLUTANTS FROM ENTERING THE SYSTEM. O ALL DUCTS ARE TO BE AIR SEALED AS PER UL181A OR UL181B. P ALL DUCT SYSTEMS ARE TO BE TESTED IN ACCORDANCE WITH 2015 IECC R403.3.2 THROUGH R403.3.5. SHEET KEYNOTES 1 PROVIDE AND INSTALL RECESSED WALL MOUNTED UNIT HEATER 8-INCHES AF.F.. 2 RETURN AIR GRILLE UP HIGH ON WALL DUCTING TO FAN COIL UNIT. 3 INSTALL FCU VERTICALLY PER MANUFACTURER'S RECOMMENDATION TO WALL PER M-501 DETAIL. ROUTE REFRIGERANT LINES THRU WALL AND UP TO ROOF LEVEL TO CORRESPONDING CONDENSING UNIT. FIRE SEAL ANY OPENINGS THROUGH FIRE RATED ASSEMBLIES. ROUTE CONDENSATE PVC PIPIN 4 INSTALL SINGLE LOUVERED WALL VENT LIKE MODEL "X-VENT 4SEB" OR EQUAL. 5 MOUNT EXHAUST FAN IN WALL PER MANUFACTURER'S RECOMMENDATION 7-FEET A.F.F. 6 PROVIDE PAINTGRIP DUCTWORK IN EXPOSED AREAS TO BE PAINTED PER ARCHITECTS COLOR APPROVAL. 1/8" = 1'-0" BUILDING A MECHANICAL FIRST FLOOR PLAN - AREA B1 # DESCRIPTION DATE 1 BID DOCUMENT 01/15/2021 1 07/08/21