Loading...
HomeMy WebLinkAboutM112a - BUILDING MECHANICAL PLANS - BUILDING AT TFCU-4 SG2SG2 -200 SG2SG2 -200 SG2SG2 -200 SG2SG2 -200 SG2SG2 -200 FCU-4 12/10 SG2SG2 -200 8ø 8ø 8ø 8ø 8ø 8ø 12/10 RG1FD FD FD FD RG1 UH-1 UH-1 UNIT A1 204 UNIT B1 206 UNIT B1 208 UNIT A2 210 ? ? ? ? UNIT A1 205 UNIT A4 203 UNIT B2 202 UNIT B2 201 UNIT B1 211 UNIT A5 213 UNIT B2 215 UNIT B3 217 UNIT A1 212 1 1 2 2 2 2 2 2 3 3 5 5 4 42 M404 1 M404 UNIT B1 207 UNIT B1 209 ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20031 JANUARY 15, 2021 BID SET M112aBUILDING MECHANICALPLANS -BUILDING ANORTH ENDAPARTMENTSCARMEL, INGENERAL NOTES A REFER TO SHEET M000 FOR GENERAL MECHANICAL NOTES, SYMBOLS AND ABBREVIATIONS. B REFERENCE M501 SERIES FOR MECHANICAL DETAILS. C REFERENCE M601 SERIES FOR MECHANICAL SCHEDULES. D COORDINATE WITH STRUCTURAL AND FRAMING PLANS PRIOR TO COMMENCING WORK. COORDINATE ALL ROUTING WITH ALL TRADES PRIOR TO FABRICATION. E SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND TYPES OF RATED CONSTRUCTION TO MAINTAIN CONSTRUCTION RATING. F THERMOSTATS TO BE 44" A.F.F. OR ALIGNED TO ADJACENT SWITCHES UNLESS OTHERWISE NOTED. G SEAL ALL FLOOR, CEILING, AND WALL PENETRATIONS. USE FIRE CAULK AT RATED ASSEMBLIES AND GENERAL SEALANT ELSEWHERE. WHERE NON-METALLIC COMPONENTS LARGER THAN 4"Ø (I.E. PVC OR CONDUIT) PENETRATES RATED ASSEMBLIES, INSTALL INTUMESCENT COLLAR. WHERE DUCTWORK LARGER THAN 4"Ø PENETRATES RATED ASSEMBLIES, INSTALL FIRE DAMPER. H SIZE AND INSTALL REFRIGERANT PIPING AND ACCESSORIES PER MANUFACTURES RECOMMENDATIONS. I ALL EXTERIOR VENT CAP AND VENT HOOD COLORS TO BE VERIFIED IN SHOP DRAWINGS. J ALL FAN COIL UNITS TO BE WALL MOUNTED UNLESS OTHERWISE INDICATED. COORDINATE MOUNTING HEIGHT WITH OTHER DISCIPLINES AND SPACE. K THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING A SIGN ATTACHED TO THE DRYER BOX IN EACH APARTMENT. THE TAG SHALL DOCUMENT THE ASSOCIATED INSTALLED DRYER VENT AND READ AS FOLLOWS: CONNECTED VENT DUCT: STRAIGHT DUCT: X FEET 90 DEG. ELBOW: COUNT=X 45 DEGREE ELBOWS: COUNT=X L PROVIDE MECHANICAL SYSTEMS IN COMPLIANCE WITH STATE AND LOCAL CODES. M DRYER AND BATHROOM EXHAUST DUCTWORK TO BE MINIMUM 28 GAUGE. N ALL HVAC SUPPLY REGISTERS, RETURN GRILLES AND DUCT TERMINATIONS ARE TO BE PROTECTED DURING CONSTRUCTION ACTIVITIES AGAINST THE INTRODUCTION OF DUST AND POLLUTANTS FROM ENTERING THE SYSTEM. O ALL DUCTS ARE TO BE AIR SEALED AS PER UL181A OR UL181B. P ALL DUCT SYSTEMS ARE TO BE TESTED IN ACCORDANCE WITH 2015 IECC R403.3.2 THROUGH R403.3.5. SHEET KEYNOTES 1 PROVIDE AND INSTALL RECESSED WALL MOUNTED UNIT HEATER 8-INCHES AF.F.. 2 PROVIDE CEILING RADIATION DAMPER. 3 RETURN AIR GRILL LOW IN THE WALL DUCTED TO THE FCU. 4 OUTSIDE AIR DUCT RISER UP TO LEVEL ABOVE. PROVIDE FIRE DAMPER AT FIRE RATED FLOOR PENETRATIONS. SEE RISER SECTION DETAIL. 5 INSTALL FCU VERTICALLY PER MANUFACTURER'S RECOMMENDATION TO WALL PER M-501 DETAIL. ROUTE REFRIGERANT LINES THRU WALL AND UP TO ROOF LEVEL TO CORRESPONDING CONDENSING UNIT. FIRE SEAL ANY OPENINGS THROUGH FIRE RATED ASSEMBLIES. ROUTE CONDENSATE PVC PIPING TO NEAREST FLOOR DRAIN. 1/8" = 1'-0" BUILDING A MECHANICAL SECOND FLOOR -AREA A 1 # DESCRIPTION DATE 1 BID DOCUMENT 01/15/2021 1 07/08/21